ABC overhead cable

Port: | Qingdao Shanghai Tianjin |
Payment Terms: | L/C,T/T |
Supply Ability: | 30000 Meter/Meters per Day |
Place of Origin: | Henan China |
Brand Name: | ZMS |
Model Number: | Overhead cable |
Insulation Material: | PVC/PE/XLPE |
Type: | Medium Voltage |
Application: | Overhead |
Conductor Material: | Aluminum |
Jacket: | PVC/PE/XLPE |
Certificate: | ISO |
Standard: | BS,ASTM,DIN,GB |
OEM/ODM: | Can |
Samples: | Free |
Core: | According to customers' request |
Packaging Detail: | ABC Cable packed in coils or on standard cable drums |
Product Description
Covered Line Wire is used primarily for 600V overhead secondary distribution lines, it's not an electrically insulated conductor and is treated as bare conductor when installed
Standard
ASTM B-230, B-231, B-232 and B-399
.
Construction
Conductors for covered line wire are aluminum alloy 1350-H19, 6201-T81, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HDPE) or crosslinked polyethylene (XLPE)
Technical specification
Code Name | Phase Conductor | Bare Neutral | Approx.Weight | ||||
---|---|---|---|---|---|---|---|
Size | Stranding | Insulation Thickness | Size | Stranding | XLPE | PE | |
AWG | – | mil | AWG | – | lbs/1000ft | ||
AAC Neutral Messenger | |||||||
Pekingese | 6 | Solid | 45 | 6 | 7/w | 63.5 | 61.7 |
Collie | 6 | 7/w | 45 | 6 | 7/w | 66.8 | 63.1 |
Dachshund | 4 | Solid | 45 | 4 | 7/w | 95.5 | 93.4 |
Spaniel | 4 | 7/w | 45 | 4 | 7/w | 100.5 | 95.4 |
Doberman | 2 | 7/w | 45 | 2 | 7/w | 152.7 | 145.7 |
Malemute | 1/0 | 19/w | 60 | 1/0 | 7/w | 242.6 | 234.2 |
6201 Alloy Neutral Messenger | |||||||
Chihuahua | 6 | Solid | 45 | 6 | 7/w | 67.6 | 65.8 |
Vizsla | 6 | 7/w | 45 | 6 | 7/w | 70.9 | 67.2 |
Harrier | 4 | Solid | 45 | 4 | 7/w | 102.0 | 99.9 |
Code Name | Phase Conductor | Bare Neutral | Approx.Weight | |||||
---|---|---|---|---|---|---|---|---|
Size | Stranding | Insulation Thickness | Size | Stranding | XLPE | PE | ||
AWG | – | mil | AWG | – | lbs/1000ft | |||
ACSR Neutral Messenger | ||||||||
Setter | 6 | Solid | 45 | 6 | 6/1 | 75.0 | 73.2 | |
Shepherd | 6 | 7/w | 45 | 6 | 6/1 | 78.3 | 74.6 | |
Eskimo | 4 | Solid | 45 | 4 | 6/1 | 113.7 | 111.6 | |
Terrier | 4 | 7/w | 45 | 4 | 6/1 | 118.7 | 113.6 | |
Chow | 2 | 7/w | 45 | 2 | 6/1 | 181.7 | 174.7 | |
Bull | 1/0 | 19/w | 60 | 1/0 | 6/1 | 288.7 | 280.3 | |
6201 Alloy Neutral Messenger | ||||||||
Whippet | 4 | 7/w | 45 | 4 | 7/w | 107.0 | 101.9 | |
Schnauzer | 2 | 7/w | 45 | 2 | 7/w | 163.3 | 156.2 | |
Heeler | 1/0 | 19/w | 60 | 1/0 | 7/w | 259.2 | 250.8 |
Note:
(1)Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.
(2)Conductor temperature of 90°C for XLPE, 75°C for PE; ambient temperatures of 40°C ; emissivity 0.9; 2ft./sec/wind in sun.
Detailed Images
Related Products
AAAC Conductor, All Aluminum Alloy ConductorAll Aluminum-Alloy Conductors (AAAC) can be used in Medium, High and Extra-High voltage transmission lines. AAAC offers better sag performance due to the high strength-to-weight ratio provided by the aluminum-alloy. In addition, AAAC provides a higher corrosion resistance than ACSR conductors. |
|
AAC All Aluminum Conductor CableAAC conductors can be installed in air. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by deficiencies in the installation. |
|
0.6/1kV overhead aerial bundled cableAerial Bundle Cable (ABC cable) is a very innovative concept for overhead powerdistribution as compared to the conventional bare conductor overhead cable. |
|
Quadruplex Service Drop WireThe quadruplex cables are suitable for use as drop cable from a pole-mounted transformer,to the service entrance of a structure,or as secondary distribution between poles.The cables should be limited to the voltages of 600 volts or less (phase to phase) at conductor temperatures not to exceed 75°C for polyethylene insulation conductors or 90°C for crosslinked polyethylene(XLPE) insulated conductors. |
Certifications
Our Company
FAQ
-
Q: Is your company a factory or trading company?
A: We are factory with our own trading company. Our trade business expands home and abroad.
-
Q:When can I get the price?
A:We usually quote within 12 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
-
Q:How can I get a sample to check your quality?
A:After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
-
Q: What is Minimum Order Quantity?
A: Generally, 1000 meters for building wire. For power cable, armored or unarmored, 500 meters.
-
Q: Which standards for your products?
A: We can produce wire and cable according to international standards: IEC, ASTM, BS, DIN, SANS, CSA or as customers’ requirement.
-
Q: How about delivery time?
A: If we have stock, delivery would be very quick. For the newly-produced products, 15 to 25 days for production.
-
Q: Payment terms:
A: Normally 30% paid as prepayment, balance paid before delivery. Or 100% L/C at sight.
-
Q: What is your packing?
A: Our electrical cable is using electrical cable wheel for the packing, the wheel can be all steel, steel frame and fumigated wood, or fumigated wooden cases. We are using different packing for different length of the cable, to ensure there will be no problem during the delivery of the products.
- Next: standards XLPE insulated Amour Cable
- Previous: Electrical Power XLPE PVC Insulated Electric Aerial Bundle Overhead Quadruplex Duplex Aluminum ABC Cable