2.5mm wire cable 450/750V electrical wire, copper wire

Port: | Qingdao |
Payment Terms: | L/C,D/A,D/P,T/T |
Supply Ability: | 1000 Kilometer/Kilometers per Week 2.5mm wire cable 450/750V electrical wire, copper wire |
Place of Origin: | Henan China |
Brand Name: | Jinshui |
Model Number: | BV, BLV, BVR, BVV, RV, RVV |
Type: | Insulated |
Application: | Indoors |
Conductor Material: | Copper or Aluminum |
Conductor Type: | Stranded or Solid |
Insulation Material: | PVC |
Rated Voltage: | 450/750V, 300/500V |
Standard: | IEC, AWG, BS |
Certificates: | ISO9001, CE, CCC, ROHS |
Packing: | Soft coil, 100 meters per coil |
Payment term: | 30% deposit in advance, 70% balance against irrevocable L/C at sight |
Supply capacity: | 1000km per week |
Delivery time: | Within 15 days after deposit received |
Port: | Qingdao |
MOQ: | 10000 meters |
Sample: | Available and free |
Packaging Detail: | 100 meters per soft roll, or export wooden drum as customer's requests for 2.5mm wire cable 450/750V electrical wire, copper wire |
2.5mm wire cable 450/750V electrical wire, copper wire
Electrical wire instruction:
Name:
Single Core PVC insulation copper wire
Structure:
Conduct—Copper / Aluminum / Copper clad aluminum
Insulation—PVC
Size:
According to Standard / Sample / Price requirement.
Description:
2.5mm wire cable 450/750V electrical wire, copper wire is used for lighting, electronic equipment, instument and communication equipment with rated voltage 450/750V or 300/500V.
Specification:
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.
Types:
Model |
Name |
BV |
Copper Core PVC Insulation Wire |
BLV |
Aluminum Core PVC Insulation Wire |
BVR |
Copper Core PVC Insulation Flexible Wire |
BVV |
Copper Core PVC Insulation PVC Sheath Round Wire |
BVVB |
Copper Core PVC Insulation PVC Sheath Flat Wire |
BLVVB |
Aluminum Core PVC Insulation PVC Sheath Flat Wire |
BV-90 |
Copper Core Heat-resistance 105°C PVC Insulation |
Specifications:
Nominal section(mm2) |
Number diameter of core (mm) |
Average dia (mm) |
Reference weight(kg/km) |
Conductor resistance at 20(Ω/km) |
|||
Min |
Max |
Copper |
Aluminium |
Copper |
aluminium |
||
1.5(A) |
1/1.38 |
2.6 |
3.2 |
20.3 |
– |
12.1 |
– |
1.5(B) |
7/0.52 |
2.7 |
3.3 |
21.6 |
– |
12.1 |
– |
2.5(A) |
1/1.78 |
3.2 |
3.9 |
31.6 |
17 |
7.41 |
12.1 |
2.5(B) |
7/0.68 |
3.3 |
4.0 |
34.8 |
– |
7.41 |
– |
4(A) |
1/2.25 |
3.6 |
4.4 |
47.1 |
22 |
4.61 |
7.41 |
4(B) |
7/0.85 |
3.8 |
4.6 |
50.3 |
– |
4.61 |
– |
6(A) |
1/2.76 |
4.1 |
5.0 |
50.3 |
29 |
3.08 |
4.61 |
6(B) |
7/1.04 |
4.3 |
5.2 |
71.2 |
– |
3.08 |
– |
10 |
7/1.35 |
5.6 |
6.7 |
119 |
62 |
1.83 |
3.08 |
16 |
7/1.70 |
6.4 |
7.8 |
179 |
78 |
1.15 |
1.91 |
25 |
7/2.14 |
8.1 |
9.7 |
281 |
118 |
0.727 |
1.20 |
35 |
7/2.52 |
9.0 |
10.9 |
381 |
156 |
0.524 |
0.868 |
50 |
19/1.78 |
10.6 |
12.8 |
521 |
215 |
0.387 |
0.641 |
70 |
19/2.14 |
12.1 |
14.6 |
734 |
282 |
0.268 |
0.443 |
95 |
19/2.52 |
14.1 |
17.1 |
962 |
385 |
0.193 |
0.320 |
120 |
37/2.03 |
15.6 |
18.8 |
1180 |
431 |
0.153 |
0.253 |
150 |
37/2.25 |
17.3 |
20.9 |
1470 |
539 |
0.124 |
0.206 |
185 |
37/2.52 |
19.3 |
23.3 |
1810 |
666 |
0.0991 |
0.164 |
100 meters per soft roll, or export wooden drum as customer's requests for 2.5mm wire cable 450/750V electrical wire, copper wire
Export wooden drum, steel-wooden drum as customer's requests for wires
- Delivery time: Within 30 days with downpayment received.
1. Are you the factory or trading company?
We are the manufacturer and 13 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.
2. When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
3. How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freightcharge should be paid.
4. What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
5. What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.