XLPE Fire Resistant Cable Price

Port: | Qingdao |
Payment Terms: | L/C,D/A,D/P,T/T |
Supply Ability: | 1000 Kilometer/Kilometers per Day |
Place of Origin: | Henan China |
Brand Name: | Jinshui |
Model Number: | YJV |
Insulation Material: | XLPE |
Type: | Medium Voltage |
Application: | Power Station |
Conductor Material: | Copper |
Jacket: | PVC |
Packaging Detail: | Wooden drum, steel-wooden drum. |
Application:
It is used to transmit and distribute power in power transmission and distribution system of 38kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical indusry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Construction:
Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE Sheathed Power Cable.
Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90°C. In short circuit, conductor highest temperature should be not more than 250°C
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90°C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250°C.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0°C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
This series includes:
Copper (aluminum) core, XLPE insulated and sheathed power cables.
Copper (aluminum) core, XLPE insulated, PE sheathed power cables.
Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables.
Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables.
Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables.
Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables
Number of cores: 1 to 6.
Packing: Wooden drum, steel-wooden drum.
- Next: electric welding cable 60245 IEC 81/82
- Previous: Electrical Wire for Sale
Contact us
Search
You May Like
-
High Voltage Cu XLPE Copper Wire Screen Armored Power Cable 3 Core 150mm2 185 mm2 240mm2 630mm2
-
33kv fire resistant electric underground 3 core 185mm 300mm 150mm high voltage cable
-
underground electric cable xlpe fire resistant cable price 150mm 185mm 300mm 500mm 630mm
-
yjv22 lv power cable xlpe insulated pvc sheathed armoured power cable
-
yjv22 lv power cable xlpe insulated pvc sheathed power cable 95mm2 120mm2 150mm2 240mm2 300mm2
-
lv power cable fire resistant xlpe insulated pvc sheathed power cable