power transportation ABC Cable approved IEC CE

power transportation ABC Cable approved IEC CE
Port: Qingdao,Tianjin,Shanghai
Payment Terms: L/C,D/P,T/T,Western Union
Supply Ability: 300 Kilometer/Kilometers per Month
Place of Origin: Henan China
Brand Name: Jinshui
Model Number: ABC Cable,Overhead cable
Insulation Material: XLPE,PE
Type: Medium Voltage
Application: Overhead
Conductor Material: Aluminum
Jacket: None
Rated Voltage: 11kv 0.6/1kv
Standard: ISO9001,ASTM,IEC
Structure: Stranded
Certification: CE,CB,SASO,ISO,ROHS,UL
Cross Section: 16-185mm2
Aftersale: one year warranty
Delivery Detail: 15 days for 20ft or as your requirement after the down payment
Packaging Detail: Standard export wooden drums or as your requirement

 

overhead power transportation ABC Cable approved IEC CE

 

 

1 Application

 

 

ABC cable has characters of powertransmitting and strong mechanical. In comparison with bare wire, aerial bundled cable (ABC cable) boasts many advantages, such as: small span in laying, higher safe reliability, better atmosphere aging resistance property. ABC cable has the priority to be used in urban and rural power transmitting construction project.

 

1   Phase conductor :
 The phase conductors shall be of H68 Condition aluminium conductor and compacted circular
stranded.

 

2   Messenger conductor :
The neutral messenger conductor shall be of aluminium alloy conductor and compacted circular
stranded.

 

3   Street Lighting conductor :
The street lighting conductors shall be of H68 Condition aluminium conductor and compacted circular
stranded.

 

4   Insulation :
The phase, messenger and street lighting conductors shall be extruded with Polyethylene ( PE ) as
insulation.

 

5   The Completed Cable
The cable consists of insulated phase and  street lighting aluminium conductors, shall be held
firmly onto the
insulated neutral messenger aluminium alloy conductor in a right-hand ( Z ) direction of lay

 

 

2 main specification

 

Number of Conductor Cross – Section  Insulated Wires  Messenger  Finished Cable 
Distribution Line  Insulated Wires  Diameter of Messenger Wire  Min. Tensile Strength  App. Max Bundle Diameter  App.Net Weight 
Number & Cross – Section  Distribution Line  Diameter of Wires  Current Carrying Capacity 30 ° C  Number & Cross – Section Current Carrying Capacity 
mm 2  Number & Cross – Section  number  mm A mm 2  A mm kN mm kg/km
2×16  2×16  7 4.6 93 . . . 15 132
2×25  2×25  7 5.9 122 18.5 200
2×35  2×35  7 6.9 129 22 280
2×50  2×50  7 8.1 158 24 370
4×16  4×16  7 4.6 83 18 265
4×25  4×25  7 5.9 111 22 400
4×35  4×35  7 6.9 131 26 550
3×25+54.6  3×25  7 5.9 112 9.6 16 30 470
3×25+1×16+54.6  3×25  7 5.9 112 1×16  60 9.6 16 30 570
3×25+2×16+54.6  3×25  7 5.9 112 2×16    9.6 16 30 640
3×35+54.6  3×35  7 6.9 138 9.6 16 33 580
3×35+1×16+54.6  3×35  7 6.9 138 1×16  60 9.6 16 33 690
3×35+2×16+54.6  3×35  7 6.9 138 2×16    9.6 16 33 750
3×50+54.6  3×50  7 8.1 168 9.6 16 36 720
3×50+1×16+54.6  3×50  7 8.1 168 1×16  60 9.6 16 36 820
3×50+2×16+54.6  3×50  7 8.1 168 2×16    9.6 16 36 890
3×70+54.6  3×70  12 9.7 213 9.6 16 38 930
3×70+1×16+54.6  3×70  12 9.7 213 1×16  60 9.6 16 38 1030
3×70+2×16+54.6  3×70  12 9.7 213 2×16    9.6 16 38 1100
3×70+1×25+54.6  3×70  12 9.7 213 1×25    9.6 16 40 1070
3×70+2×25+54.6  3×70  12 9.7 213 2×25    9.6 16 40 1170
3×70+70  3×70  12 9.7 213 10.2 20.6 41 970
3×70+1×16+70  3×70  12 9.7 213 1×16  60 10.2 20.6 41 1080
3×70+2×16+70  3×70  12 9.7 213 2×16    10.2 20.6 41 1150
3×95+70  3×95  19 11.5 258 10.2 20.6 44 1200
3×95+1×16+70  3×95  19 11.5 258 1×16  60 10.2 20.6 44 1300
3×95+2×16+70  3×95  19 11.5 258 2×16    10.2 20.6 44 1380
3×120+70  3×120  19 12.8 300 10.2 20.6 46 1430
3×120+1×16+70  3×120  19 12.8 300 1×16  60 10.2 20.6 46 1540
3×120+2×16+70  3×120  19 12.8 300 2×16    10.2 20.6 46 1600
3×150+70  3×150  19 14.5 344 10.2 20.6 48 1680
3×150+1×16+70  3×150  19 14.5 344 1×16  60 10.2 20.6 48 1780
3×150+2×16+70  3×150  19 14.5 344 2×16    10.2 20.6 48 1850
3×120+95  3×120  19 12.8 300 12.9 27.9 47 1500
3×120+1×16+95  3×120  19 12.8 300 1×16  60 12.9 27.9 47 1620
3×120+2×16+95  3×120  19 12.8 300 2×16    12.9 27.9 47 1680
3×150+95  3×150  19 14.5 344 12.9 27.9 49 1740
3×150+1×16+95  3×150  19 14.5 344 1×16  60 12.9 27.9 49 1880
3×150+2×16+95  3×150  19 14.5 344 2×16    12.9 27.9 49 1940
1×16+25  1×16  1 4.4 75 5.9 7.4 15 140
1×25+35  1×25  7 5.9 100 6.9 10.3 17 200
1×35+50  1×35  7 1  6.9 125 8.1 14.2 20 275
3×16+25  3×16    4.4 70 5.9 7.4 22 275
3×25+35  3×25  7 5.9 90 6.9 10.3 26 400
3×35+50  3×35  7 6.9 115 8.1 14.2 30 575
3×50+70  3×50  7 8.1 140 9.6 20.6 35 750
3×70+95  3×70  7 9.6 180 11.4 27.9 41 1050
3×120+95  3×120  19 12.8 250 11.4 27.9 47 1550
4×16+25  4×16  1 4.4 70 5.9 7.4 24 375
4×25+35  4×25  7 5.9 90 6.9 10.3 28 550
4×35+50  4×35  7 6.9 115 8.1 14.2 32 750
4×50+70  4×50  7 8.1 140 9.6 20.6 38 1000
4×70+95  4×70  7 9.6 180 11.4 27.9 45 1350
1×16+25  1×16  75 5.9 7,4  14 140
1×16+1×16+25  1×16  1 4.4 70 1×16  60 5.9 7.4 15 225
3×16+1×16+25  3×16  1 4.4 60 1×16  60 5.9 7.4 22 350
3×25+1×16+35  3×25  7 5.9 80 1×16  60 6.9 10.3 26 475
3×35+1×16+50  3×35  7 6.9 95 1×16  60 8.1 14.2 30 625
3×50+1×16+70  3×50  7 8.1 120 1×16  60 9.6 20.6 35 800
3×70+1×16+95  3×70  7 9.6 150 1×16  60 11.4 27.9 41 1100
4×16+1×16+25  4×16  1 4.4 60 1×16  60 5.9 7.4 25 450
4×25+1×16+35  4×25  7 5.9 80 1×16  60 6.9 10.3 30 610
4×35+1×16+50  4×35  7 6.9 95 1×16  60 8.1 14.2 34 810
4×50+1×16+70  4×50  7 8.1 120 1×16  60 9.6 20.6 40 1060
4×70+1×16+95  4×70  7 9.6 150 1×16  60 11.4 27.9 47 1420

 

3 Picture of ABC

 

Tags: ,

Contact us

 

 

 

Search

You May Like

  • No related articles