Multi-Pair multi-core Shielded instrumentation cable BS5308 Cable Part 2 Type 2 PVC-IS-OS-SWA-PVC/ RE-Y(St)Y PIMF SWAY

Port: | qingdao |
Payment Terms: | L/C,T/T |
Supply Ability: | 50 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | hongda |
Model Number: | instrumentation cable |
Insulation Material: | PVC |
Type: | Low Voltage |
Application: | Industrial |
Conductor Material: | Copper |
Jacket: | PVC |
Shielding: | Foil |
Delivery Detail: | 20 days or depend on the quantity |
Packaging Detail: | drum |
Instrumentation Cable
For use in installations designed to connect electrical instrumentation circuits and provide communication services in and around process plants. Suitable for direct burial applications.
Specification of instrument cable:
Instrument Cable Conductors:
0.5mm – class 5 flexible copper
0.75mm – class 5 flexible copper
1.5mm – class 2 stranded copper
Insulation: PE (Polyethylene)
Screen: CAM (Collective Aluminium Mylar)
Bedding: PE (Polyethylene)
Armour: SWA
Outer Sheath: PVC (Polyvinyl-Chloride)
Voltage Rating: 300/500volts
Temp. Rating: 65 C
Flexible instrumentation multi-core cables about PVC insulated and twisted parallel cable
Standard: National Standard GB/T 5023; IEC60227
Rated Voltage: 300/300V;
Construction: 1. annealed flexible copper conductor
2.PVC insulated
Application: used for electric appliance, electric tool, electric instruments and lighting, automatic system
Application of insulated cable Instrument Cable :
It is used to transmit and distribute power on the power line of A. C. Rated voltage 0.6/1kV.
XLPE insulated electric cable Instrument Cable 0.6/1kv | |||||||||||
norminalsectional area | insulati-on thicknes | sheath thickness(mm) | overal diameter of cable (mm) | D.C resistance of conductor(km) | current rating | ||||||
in air(A) | direct in soil(A) | ||||||||||
cu | Al | cu | Al | cu | Al | ||||||
1×1.5 | 0.7 | 1.5 | 6 | <=12.1 | <=12.1 | 30 | 25 | 45 | 35 | ||
1×4 | 0.7 | 1.5 | 7 | <=7.41 | <=7.41 | 45 | 35 | 60 | 50 | ||
1×6 | 0.7 | 1.5 | 7 | <=3.08 | <=4.61 | 55 | 45 | 70 | 55 | ||
1×35 | 0.9 | 1.5 | 12 | <=0.524 | <=0.868 | 175 | 140 | 190 | 150 | ||
1×50 | 1 | 1.5 | 13 | <=0.387 | <=0.641 | 210 | 170 | 225 | 180 | ||
1×70 |
1 .1 |
1.5 | 14 | <=0.268 | <=0.443 | 270 | 215 | 280 | 225 | ||
1×95 | 1.1 | 1.5 | 16 | <=0.193 | <=0.320 | 340 | 275 | 335 | 270 | ||
1×120 | 1.2 | 1.5 | 18 | <=0.153 | <=0.253 | 400 | 320 | 380 | 305 | ||
1×150 | 1.4 | 2 | 21 | <=0.124 | <=0.206 | 460 | 370 | 425 | 340 | ||
1×185 | 1.6 | 2 | 23 | <=0.0991 | <=0.164 | 530 | 415 | 480 | 375 | ||
1×240 | 1.7 | 2 | 25 | <=0.0754 | <=0.125 | 625 | 490 | 555 | 435 | ||
… | |||||||||||
3×1.5 | 0.7 | 1.5 | 10 | <=12.1 | <=12.1 | 25 | 25 | 30 | 30 | ||
3×2.5 | 0.7 | 1.5 | 11 | <=7.41 | <=12.1 | 30 | 25 | 35 | 30 | ||
3×4 | 0.7 | 1.5 | 12 | <=4.61 | <=7.41 | 40 | 30 | 50 | 40 | ||
… | |||||||||||
Attention: We can provide more info than above data, if needed.The above are just some examples. |
Using features of insulated cable Instrument Cable :
1. Rated voltage: Uo/U: 0.6/1kV
2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 160oC.
4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
Model: insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable
Contact us
Search
You May Like
-
300/500V BS5308 1 pair 1.5mm2 PE/XLPE insulated Galvanized SWA armour instrumentation cable
-
cu conductor xlpe/pe/pvc insulation instrumentation cable 300/500V RE-2Y(ST)Y PIMF-SWA
-
PVC/PE insulated in1.5mm2 individual or overall screened instrumentation cable
-
1 Pair 12 twisted Pairs 1.5mm2 Cu/PVC/OSCR/PVC instrumentation cable
-
Multi pairs 4 pairs 20 pairs TIN Cu/PVC/ISCR/OSCR instrumentation cable 1.5mm