flame retardant zr-bvr building used cable / pvc insulated copper conductor electrical wire
flame retardant wire
electric wire
Specification Sizes and Technological Data
- Conductor: pure copper
- Rated volatge:450/750V, 300/500V
- We can also customize electrical wire and cable as your request
- Prompt delivery
- Factory direct sale
- The sample for sale
|
BV 300/500V |
||||
|
Nominal Section sqmm |
Number/ Diameter of Core mm |
Maximum Outer Diameter mm |
Reference Weight kg/km |
20Conductor resistance at 20 (Ω/km) |
|
0.5 |
1/0.80 |
2.4 |
8.5 |
36.0 |
|
0.75(A) |
1/0.97 |
2.6 |
11.1 |
24.5 |
|
0.75(B) |
7/0.37 |
2.8 |
12.0 |
24.5 |
|
1.0(A) |
1/1.13 |
2.8 |
13.9 |
18.1 |
|
1.0(B) |
7/0.43 |
3.0 |
15.0 |
18.1 |
|
Model |
Name |
|
BV |
Copper core PVC insulation power line electric wire |
|
BLV |
Aluminium core PVC insulation power line |
|
BVR |
Copper core PVC insulation flexible power line |
|
BVV |
Copper core PVC insulation PVC sheath round power line electric wire |
|
BVVB |
Copper core PVC insulation PVC sheath parellel power line |
|
BLVVB |
Aluminium core PVC insulation PVC sheath parellel power line |
|
BV-105 |
105 Copper core heat-resistance 105 PVC insulation electric wire |
electric wire
Application
450/750V BV is used for rated voltage up to and including 450/750V of the power system, high rise buildings , subway,industrial and mining enterprises,and lines in a communication network,especially the emergency circuits.
| |
|
| BV- PVC insulated copper electric wire, That is a single strand with a core of hard-line consists of a hard copper wire in a plurality of wire to wear tube, due to the high hardness, not easy to turn around, therefore, it is suitable for wall go straight road through the tube, not turning around tube. The common BV line color: red, yellow, green, black, white, two-color (yellow and green), brown. | |
| BVR-PVC insulated soft copper electric wire, multi-conductor cord, BVR is used multi uniform thickness with copper wire, wire structure: PVC insulated + flex copper conductors, the only difference between BV and BVR is that the wire, R type wire conductor flex copper wire, which increase the number of conductors roots, reducing the diameter of a single conductor, single conductor diameter of less than 1 mm, so that BVR wire is very flex. Due to the low hardness, BV wire laying angle requirements more greatly reduced, when pipe trough threading and trunking is more convenient, suitable for turning wear tube. | |
flame retardant wire
| Type | Spec. (mm2) | Application | Color |
| BV elelctric wire | 1 |
illumination |
red, yellow, blue, green, two-color (yellow and green) |
| 1.5 |
illumination |
red, yellow, blue, green, two-color (yellow and green) | |
| 2.5 |
Illumination, socket, wall hanging air conditioner |
red, yellow, blue, green, two-color (yellow and green) | |
| 4 |
Central air conditioner, the main line into the household (small set) |
red, yellow, blue, green, two-color (yellow and green) | |
| 6 |
Household bus |
red, yellow, blue, green, two-color (yellow and green) | |
| 10 |
Household bus |
red, yellow, blue, green, two-color (yellow and green) | |
| 16 |
Household bus (200m2) |
red, yellow, blue, green, two-color (yellow and green) | |
| BVR elelctric wire |
1 | illumination | red, yellow, blue, green, black, white, two-color (yellow and green), brown |
| 1.5 | illumination | red, yellow, blue, green, black, white, two-color (yellow and green), brown | |
| 2.5 | illumination, socket, wall hanging air conditioner | red, yellow, blue, green, black, white, two-color (yellow and green), brown | |
| 5 | Center air conditioner, the main line into the household (small set) | red, yellow, blue, green, black, white, two-color (yellow and green), brown | |
| 6 | Household bus | red, yellow, blue, green, black, white, two-color (yellow and green), brown | |
| 10 | Household bus | red, yellow, blue, green, black, white, two-color (yellow and green), brown | |
| 16 | Household bus (200m2) | red, yellow, blue, green, black, white, two-color (yellow and green), brown |
flame retardant wire
Electric Wire power meter
| Cross sectional area | 220V (W) | 380V (W) | Cross sectional area | 220V (W) | 380V (W) |
| 1 | 2900 | 6500 | 6 | 10000 | 22000 |
| 1.5 | 4200 | 9500 | 10 | 13800 | 31000 |
| 2.5 | 5800 | 13000 | 16 | 18900 | 42000 |
| 4 | 7600 | 17000 | 25 | 24400 | 55000 |
| Note: These power above are the limit power, due to environmention there are some deviation. Pls set aside 20% margin when you purchase it. This data just for your reference. | |||||
electric wire
The difference between BVV and BV, BVV is more one jacket than BV. BVV is suitable for the power plant, electric appliances, instrumentation and telecommunications equipment which the a.c. voltage below 450/750V. The long term working temperature no more than 65 degrees. The normal cross sectional area from 0.75mm2 to 10mm2, divide 0.75mm2, 1.0mm2, 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2 seven sizes.
flame retardant wire
How to distinguish excellent quality wire and linferior quality wire
electric wire
Package:
7. Company information
Zhengzhou hongda cable Co., Ltd.
Established Year:1999
Registered capital of RMB:5,000,000
Factory Area:300,000m2
Main products: ABC cable Areial bundle cable ,XLPE insulated power cable ,PVC insulated power cable ,electrical wire ,bare aluminum conductor(AAC AAAC ACSR )and so on
Main export county: USA, Philippines, Malaysia, Indonesia, Venezuela, Colombia, Mexico, Dominica, India, South Africa, Zambia, Kenya and so on.
flame retardant wire
The BV Electrical wire production process
Any other information of cables pls contact with me:
flame retardant wire