VCT 600V 4x1c cu xlpe cable 16mm, Polyvinylchloride Insulated Power Cable
Product Description
For overhead distribution of electrical energy, such as a supply power, from pole-mounted transformer to the user’s service head where connection to the service entrance cable is made.
Also, for temporary services and street light installations.
ASTM B1 (Hard-Drawn Copper Wire.)
ASTM B3 (Hard-Drawn Copper Wire.)
ASTM B8 (Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.)
- Conductor: Soft annealed, or hard-drawn copper, solid per ASTM B1 or B3, compressed Class B or A stranding, or unilay-compressed per ASTM B8.
- Insulation: Black thermoplastic polyethylene (HDPE), high density or XLPE insulation.
- Neutral: Hard drawn bare copper.
| Code word | Copper Phase Conductor | HD CU, Neutral Messenger | Weight | |||||
| Size AWG or kcmil | Number or Strands | Insulation thickness | Size AWG or kcmil | Number or Strands | Rated Strength | PE | XLPE | |
| mil | Ib | Ib/kft | Ib/kft | |||||
| Copper Conductor & Neutral Messenger | ||||||||
| Theta | 8 | 7 | 45 | 10 | 1 | 529 | 97 | 96 |
| lota | 8 | 7 | 45 | 8 | 1 | 826 | 116 | 115 |
| Kappa | 8 | 7 | 45 | 8 | 7 | 777 | 117 | 116 |
| Omega | 8 | 1 | 45 | 8 | 1 | 826 | 113 | 112 |
| Lambda | 6 | 7 | 45 | 8 | 1 | 826 | 149 | 149 |
| Omicron | 6 | 7 | 45 | 6 | 1 | 1280 | 179 | 179 |
| Sigma | 6 | 7 | 45 | 6 | 7 | 1228 | 181 | 180 |
| (No Code) | 4 | 7 | 45 | 4 | 1 | 1970 | 279 | 279 |
| (No Code) | 4 | 7 | 45 | 4 | 7 | 1938 | 282 | 282 |
| (No Code) | 2 | 7 | 45 | 2 | 7 | 3050 | 442 | 441 |
| (No Code) | 1/0 | 19 | 60 | 1/0 | 7 | 4752 | 703 | 702 |
| Code word | Copper Phase Conductor | HD CU, Neutral Messenger | Weight | |||||
| Size AWG or kcmil | Number or Strands | Insulation thickness | Size AWG or kcmil | Number or Strands | Rated Strength | PE | XLPE | |
| mil | Ib | Ib/kft | Ib/kft | |||||
| Copper Conductor & Neutral Messenger | ||||||||
| Pica | 8 | 7 | 45 | 10 | 1 | 529 | 149 | 160 |
| Bodoni | 8 | 7 | 45 | 8 | 1 | 826 | 167 | 179 |
| Garamond | 8 | 7 | 45 | 8 | 7 | 777 | 169 | 180 |
| Columbian | 8 | 1 | 45 | 8 | 1 | 826 | 164 | 174 |
| Tudor | 6 | 7 | 45 | 8 | 1 | 826 | 232 | 246 |
| Futura | 6 | 7 | 45 | 6 | 1 | 1280 | 262 | 276 |
| Gothic | 6 | 7 | 45 | 6 | 7 | 1228 | 263 | 278 |
| Nonpareil | 4 | 7 | 45 | 6 | 1 | 1280 | 363 | 381 |
| Ionic | 4 | 7 | 45 | 4 | 1 | 1970 | 411 | 429 |
| Caslon | 4 | 7 | 45 | 4 | 7 | 1938 | 413 | 432 |
| Minion | 2 | 7 | 45 | 4 | 1 | 1970 | 571 | 594 |
| Primer | 2 | 7 | 45 | 4 | 7 | 1938 | 574 | 596 |
| Century | 2 | 7 | 45 | 2 | 7 | 3050 | 651 | 674 |
| Corinthian | 1/0 | 19 | 60 | 1/0 | 7 | 4752 | 1036 | 1073 |
| (No Code) | 2/0 | 19 | 60 | 1/0 | 7 | 4752 | 1214 | 1255 |
| Doric | 2/0 | 19 | 60 | 2/0 | 7 | 5926 | 1301 | 1342 |
| (No Code) | 3/0 | 19 | 60 | 1/0 | 7 | 4752 | 1438 | 1485 |
| Tuscan | 3/0 | 19 | 60 | 3/0 | 7 | 7366 | 1634 | 1681 |
| composite | 4/0 | 19 | 60 | 4/0 | 7 | 9154 | 2054 | 2107 |
| Code word | Copper Phase Conductor | HD CU, Neutral Messenger | Weight | |||||
| Size AWG or kcmil | Number or Strands | Insulation thickness | Size AWG or kcmil | Number or Strands | Rated Strength | PE | XLPE | |
| mil | Ib | Ib/kft | Ib/kft | |||||
| Copper Conductor & Neutral Messenger | ||||||||
| Atlanta | 6 | 7 | 45 | 6 | 1 | 1280 | 344 | 359 |
| Tallahassee | 6 | 7 | 45 | 6 | 7 | 1228 | 346 | 361 |
| Baton Rouge | 4 | 7 | 45 | 4 | 1 | 1970 | 542 | 560 |
| Richmoud | 4 | 7 | 45 | 4 | 7 | 1938 | 545 | 563 |
| (No Code) | 2 | 7 | 45 | 4 | 7 | 1938 | 782 | 805 |
| Jackson | 2 | 7 | 45 | 2 | 1 | 3003 | 856 | 879 |
| Seatle | 2 | 7 | 45 | 2 | 7 | 3050 | 860 | 883 |
| (No Code) | 1/0 | 19 | 60 | 2 | 7 | 3050 | 1245 | 1282 |
| Nashville | 1/0 | 19 | 60 | 1/0 | 7 | 4752 | 1368 | 1405 |
| Lincoln | 2/0 | 19 | 60 | 2/0 | 7 | 5926 | 1720 | 1761 |
| Raleigh | 3/0 | 19 | 60 | 3/0 | 7 | 7366 | 2163 | 2209 |
| Denver | 4/0 | 19 | 60 | 4/0 | 7 | 9154 | 2721 | 2773 |
Weights and dimensions will vary from manufacturer, if critical please check at time of order.
Other conductor sizes and core counts are available upon request.
Power Cable Markings
All 4 core armoured Cable will carry the following items on the surface print:
Manufacturers Name
Electric Cable
Voltage Designation
British Standard Number
Cross Sectional Area
No. of Cores
Type of Cable
Date
NOTE: Items 1 to 4 will also be embossed on the Oversheath of the cable
Some special cable marking accept customized.
Company & Certification:
The package of power Cable.
1. Export wooden drum, wooden iron drum and other export standard package
2. Each Drum 1000m or depending on customized.
3. Then pack by plastic kitting bag or plastic film.
4. Fixed with plank or board.
Any other information of pls contact with me:
Vivian Yuan | Sales Director
Zhengzhou Hongda Cable CO., LTD.
Landline: +86 371 6097 5616 | Fax: +86 371 6097 5616
Email: sale04 @ zzhongdacable.com.cn | Skype ID: xinyuanyy
Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725
Address: Houzhai Industrial Park, Erqi Zone, Zhengzhou, China,450000