0.6/1KV LV AAC AAAC ABC cable electrical three phase overhead Aerial Bundle Cable size

Port: | Qingdao, Shanghai, Ningbo, Tianjin, Guangzhou, Dalian, Shenzhen, Yingkou |
Payment Terms: | L/C,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 60000 Kilometer/Kilometers per Month The capacity depending on aerial bundle cable size |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | aerial bundle cable size |
Insulation Material: | XLPE |
Type: | Low Voltage |
Application: | Overhead |
Conductor Material: | Aluminum |
Jacket: | PVC |
Sheath color: | Black or as your request |
Application: | Industrial and overhead |
Standard: | ASTM, BS, NFC, IEC, DIN Standard |
Properties: | High safety & competitive price |
aerial bundle cable Rated voltage: | 0.6/1KV low voltgate |
Number of Cores: | 12 3 4 5 6 core or as your required |
aerial bundle cable size: | AWG10 16 25 35 50 70 95 120 150 |
Insulation: | PVC Insulation Control Cable |
Reference Standard: | NFC_33-209 |
Packaging Detail: | ABC cable ( Aerial Bundle Cable) is adopt for export wooden drum, wooden iron drum or other export standard package. We can also pack it according to your requirement. |
ABC Cable sample: we can offer the sample free. If possible we also can be support the clip for fitting, pls feel free to contact me.
0.6/1KV LV AAC AAAC ABC cable electrical three phase overhead Aerial Bundle Cable size
Aerial Bunched Cables are used in theft prone areas, or as a replacement of bare conductors in rural areas, forest, hilly terrains etc. These AB cables give highly reliable performance, good protection against line and ground fault and good adaptability. Manufactured from quality raw material, these cables are durable and are safe for different electrical environments. These functional cables are available in standard dimensions and can also be customized as per client's requirement.
Features:
- HONGDA make Aerial Bunched Cable (ABC) is a novel concept for Overhead Power Distribution System
- HONGDA make Aerial Bunched Cable are designed, manufactured & tested conforming to IS: 14255, IS: 7098 (P-I) & other international specifications like IEC, NFC etc.
Applications:
ABC can conveniently be used:
- In theft prone areas
- As replacement of bare conductors in rural areas, in forest and in other localities like narrow streets where the space is limited
- As replacement of bare conducts where reliability of supply is of prime importance
- As replacement of bare lines where high degree of stability of supply voltage is of importance
- In hilly terrains where cost of erection of overhead lines or under ground cable becomes very high
- As reinforcement of existing system without increasing voltage
- For temporary supplies
- Reduces burning of transformers and maintenance
Advantages:
In comparison to bare overhead distribution lines, AB Cables have very high reliability during the services. As the power and neutral conductors are insulated with the best dielectric material, resulting in the following advantages:
- Less fault rate on account of good protection against line and ground fault by high winds or falling trees or birds especially in hilly areas & forests as encountered in Rural distribution networks
- High Insulation resistance to earth in all polluted atmosphere. Negligible currents and low losses
- Multiple circuits of Power and Telephone Cables could be strung in the same set of poles or any other supports like walls etc
- Better adaptability to run concurrently with existing over-head bare conductor system without any interference
- High capacitance and low inductance leading to low impedance of lines
- Lower voltage drop, higher current carrying capacities, vis-a-vis better Voltage Regulation
- Longer spans and longer distance lines are possible with better systems stability
- AB Cables are much safer then bare Conductors
- It can be over hung in dense vegetation and forests
- Additional connections can be easily and quickly made with hot-line connectors
- Total lines costs are reduced
- Maintenance costs are reduced
- Very difficult to tap the AB cables, thus reducing theft which leads to lower distribution loses
Click and Ask for Price
ABC Cable Application:
The assembled insulated conductor shall be suitable for use in a system having a standard operating voltage not exceeding 600/1000V. The cores of an aerial bundled conductor shall be laid-up with a left-hand lay. The length of lay shall be 55-75 times the diameter of a phase conductor.
ABC Cable Construction:
The conductors shall be stranded circular and ,except where otherwise stated,shall comply with all the requirement for class 2 compacted stranded circular conductors of IEC60502.
1. Conductor: Aluminum conductor 2. Insulation: XLPE /PE
|
ABC Cable Specification:
(1)Self-supporting
Phase |
Phase |
Phase |
|||
AAC+UV-XLPE |
Compact Conductor |
UV-XLPE Insulation |
|||
No.X Normal Cross Section of Cores |
No.of Al Wires |
Overall Diameter |
Normal Thickness |
Min. |
Diameter |
No. X mm2 |
– |
mm |
mm |
mm |
mm |
1 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
2 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
2 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
2 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
2 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
2 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
2 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
2 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
2 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
2 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
2 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
2 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
3 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
3 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
3 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
3 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
3 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
3 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
3 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
3 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
3 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
3 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
3 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
4 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
4 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
4 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
4 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
4 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
4 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
4 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
4 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
4 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
4 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
4 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
(2) Phase + Neutral
Phase | Neutral | Phase | Neutral | |||
AAC+UV-XLPE | AAAC | Compact Conductor | UV-XLPE Insulation | Conductor | ||
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.of Al.Wire | Overall Dia. |
Normal Thickness |
Min. | No./Dia. of Al Alloy Wire |
No. X mm2 | No. X mm2 | – | mm | mm | Min. | No./mm |
1 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 |
1 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 |
1 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 |
1 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 |
1 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 |
1 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 |
1 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 |
1 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 |
1 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 |
1 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 |
2 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 |
2 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 |
2 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 |
2 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 |
2 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 |
2 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 |
2 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 |
2 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 |
2 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 |
2 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 |
3 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 |
3 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 |
3 X 35 | 1 X 35 | 7 | 7 | 1.4 | 1.16 | 7/2.50 |
3 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 |
3 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 |
3 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 |
3 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2.80 |
3 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 |
3 X 185 | 1 X 185 | 36 | 16.2 | 2 | 1.7 | 37/2.50 |
3 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 |
ABC Cable sample: we can offer the sample free. If possible we also can be support the clip for fitting, pls feel free to contact me.
Packaging & shipping
Packaging Detail: export wooden drum pack abc cable ,wooden iron drum and other export standard package
Delivery Detail: 10-15 days and also depend on the quantity
Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.
Sea freight:
FOB/C&F/CIF quotation are all available.
Any require contact me as follows:
Vivian Yuan | Sales Director
Zhengzhou Hongda Cable CO., LTD.
Email: sale04 @ zzhongdacable.com.cn
Skype ID: xinyuanyy
Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725
- Next: 100 sq mm Aluminum Conductor Steel Reinforced acsr dog conductor with price list
- Previous: 35 50 100 sq mm Aluminum Conductor Steel Reinforced overhead bare fox acsr dog rabbit conductor price list
Contact us
Search
You May Like
-
120mm Copper 33kV XLPE cable electric cable three phase price--Underground cable specifications
-
Electric cable three phase 3x120mm2 3x185mm2 3x240mm2 33kV XLPE cable price
-
Three phase electric cable for home decoration and home appliances use
-
Power transmission line electric cable three phase overhead abc cable
-
Power transmission line electric cable three phase abc cable