0.6/1kv Quadruplex conductor 600V secondary types of electric conductors URD cable aluminum conductor

Port: | Qingdao port for overhead transmission line conductor |
Payment Terms: | L/C,T/T,Western Union,MoneyGram |
Supply Ability: | 1600 Kilometer/Kilometers per Month overhead transmission line conductor |
Place of Origin: | Henan China |
Brand Name: | Hongda bare conductor |
Model Number: | overhead transmission line conductor |
Insulation Material: | no insulation |
Type: | Low Voltage |
Application: | Overhead |
Conductor Material: | Aluminum |
Jacket: | no sheath |
Material: | aloy aluminum |
Mark: | CCC, IEC |
Standard: | AWG, IEC, BS, ASTM |
Using: | Overhead, power transmission lines |
Cable Type: | overhead transmission line conductor |
Conductor Type: | Stranded Aluminum Wire AAC |
Insulation: | XLPE Insulation |
Rated voltage: | 600/1000 Volts |
Core: | Multi-core |
Packing: | Wooden Drum |
Delivery Detail: | Shipped in 15 days after payment |
Packaging Detail: | standard export wooden drums each end of cable shall be firmly and properly secured to drum for overhead transmission line conductor |
600 VOLT SECONDARY UD – DUPLEX / TRIPLEX / QUADRUPLEX
APPLICATION
Directly buried or installed in ducts for 600 volt secondary distribution.
PRODUCT FEATURES
Concentric stranded or compressed 1350-H19 aluminum conductor, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral, triple yellow striped or solid yellow. Black neutrals may be specified if desired.
STANDARDS
ASTM B-230, B-231 amd ICEA S-105-692 UL Standard 854 for Type USE-2
Federal Specification JC-30B NEC
HONGDA CABLE Duplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor |
|||||||||||
Code Word |
Phase Conductors |
Neutral Conductor |
Single |
Outside |
Weight |
Ampacity |
|||||
Size |
Strand |
Insulation Thickness |
Size |
Strand |
Insulation Thickness |
Direct Burial |
In Duct |
||||
Bard |
8 |
7/W |
60 |
8 |
7/W |
60 |
.262 |
.524 |
76 |
70 |
55 |
Clafin |
6 |
7/W |
60 |
6 |
7/W |
60 |
.299 |
.596 |
91 |
95 |
70 |
Delgado |
4 |
7/W |
60 |
4 |
7/W |
60 |
.345 |
.690 |
129 |
125 |
90 |
Everett |
2 |
7/W |
60 |
2 |
7/W |
60 |
.403 |
.808 |
187 |
187 |
100 |
HONGDA CABLE Triplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor |
|||||||||||
Code Word |
Phase Conductors |
Neutral Conductor |
Single |
Outside |
Weight |
Ampacity |
|||||
Size |
Strand |
Insulation Thickness |
Size |
Strand |
Insulation Thickness |
Direct Burial |
In Duct |
||||
Erksine |
6 |
7/w |
60 |
6 |
7/w |
60 |
.299 |
.646 |
143 |
95 |
70 |
Vassar |
4 |
7/w |
60 |
4 |
7/w |
60 |
.345 |
.754 |
203 |
125 |
90 |
Stephens |
2 |
7/w |
60 |
4 |
7/w |
60 |
.403 |
.842 |
264 |
165 |
120 |
Ramapo |
2 |
7/w |
60 |
2 |
7/w |
60 |
.403 |
.874 |
294 |
165 |
120 |
Brenau |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
.522 |
1.064 |
408 |
215 |
160 |
Bergen |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.522 |
1.133 |
465 |
215 |
160 |
Converse |
2/0 |
19/w |
80 |
1 |
19/w |
80 |
.566 |
1.174 |
502 |
245 |
180 |
Hunter |
2/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.566 |
1.228 |
560 |
245 |
180 |
Hollins |
3/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.616 |
1.276 |
606 |
280 |
205 |
Sweetbriar |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.672 |
1.389 |
739 |
315 |
240 |
Monmouth |
4/0 |
19/w |
80 |
4/0 |
19/w |
80 |
.672 |
1.457 |
828 |
315 |
240 |
Pratt |
250 |
37/w |
95 |
3/0 |
19/w |
80 |
.748 |
1.538 |
893 |
345 |
265 |
Wesleyan |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
.851 |
1.736 |
1166 |
415 |
320 |
Rider |
500 |
37/w |
95 |
350 |
37/w |
95 |
.979 |
2.035 |
1663 |
495 |
395 |
Fairfield |
750 |
61/w |
110 |
500 |
37/w |
95 |
1.118 |
2.860 |
2304 |
615 |
525 |
HONGDA CABLE Quadruplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor |
|||||||||||
Code Word |
Phase Conductors |
Neutral Conductor |
Single |
Outside |
Weight |
Ampacity |
|||||
Size |
Strand |
Insulation Thickness |
Size |
Strand |
Insulation Thickness |
Direct Burial |
In Duct |
||||
Tulsa |
4 |
7/w |
60 |
4 |
7/w |
60 |
.345 |
.833 |
258 |
119 |
85 |
Dyke |
2 |
7/w |
60 |
4 |
7/w |
60 |
.403 |
.938 |
346 |
153 |
115 |
Wittenberg |
2 |
7/w |
60 |
2 |
7/w |
60 |
.403 |
.973 |
375 |
153 |
115 |
Notre Dame |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
.522 |
1.188 |
541 |
198 |
150 |
Purdue |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.522 |
1.260 |
596 |
198 |
150 |
Syracuse |
2/0 |
19/w |
80 |
1 |
19/w |
80 |
.566 |
1.316 |
664 |
225 |
170 |
Wake Forest |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.672 |
1.560 |
979 |
290 |
225 |
Rust |
250 |
37/w |
95 |
3/0 |
19/w |
80 |
.748 |
1.725 |
1,176 |
319 |
240 |
Slippery Rock |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
.851 |
1.945 |
1,544 |
385 |
305 |
Wofford |
500 |
37/w |
95 |
350 |
37/w |
95 |
.851 |
2.348 |
2,174 |
467 |
420 |
Westminster |
750 |
61/w |
110 |
350 |
37/w |
95 |
.979 |
2.722 |
2,816 |
615 |
492 |
Ampacity: 90°C conductor temperature, 20°C ambient, RHO 90, 100% load factor for three conductor triplex with neutral carrying only unbalanced load.
All Yellow Extruded Stripe, cable is XLP insulation.
* To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
The above data are approximate and subject to normal manufacturing tolerances.
Other cross-sections can be offered upon request.
Quadruplex Service Drop -Aluminum Conductor
Applications
Used as overhead cable to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
Triplex service drop -Aluminum Conductor
Applications
Used as overhead cable to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
Duplex Service Drop -Aluminum Conductor
Applications
Primarily used as overhead cable or air cable for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
Our company start manufacture Low Voltage Cable since 1999, for over 17 years experience.
Start exporting worldwide since 2007, More than 8 years Exporting expericance.
There are more than15 sets equipment for producing the Low Voltage Cable in our factory. A new workshop under building, will come to running this year.
Full set test equipment can be found in the factory, also there would be routine inspector to confirm the quality in time during the production.
1. We have a large production base, and advanced production equipment
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Attractive design and various styles
5. Free issue:packaging list,invoice,CD installation
6. Powerful technology R&D team
7. Strict quality assurance system and perfect testing means
8. Advanced process equipment
9. Painted with powerful antiseptic Anticorrosion material paints
10. Delivery on time
11. Our roller coaster sales to Middle East,Africa,Russia,Southeast Asia, etc.
12.We have a good reputation in the overseas
Contact information
If you can't find the product you need in the list, please contact me, and I will serve for you wholeheartedly !!!
We are looking forward to your inquiry and nice cooperaton.
- Next: MV spaced aerial 15/25/35KV SAC cable with aluminium conductor
- Previous: armoured Copper SWA Armoured PVC Sheath Construction Cable