600 / 1000 volts 3x70mm2 1x54.6mm2 1x16mm2 abc cable with NF C 33-209 aerial bundled cable

600 / 1000 volts 3x70mm2 1x54.6mm2 1x16mm2 abc cable with NF C 33-209 aerial bundled cable
Port: Qingdao port for quadruplex abc cable
Payment Terms: L/C,T/T,Western Union,MoneyGram
Supply Ability: 3200 Kilometer/Kilometers per Month quadruplex abc cable
Place of Origin: Henan China
Brand Name: Hongda urd cable
Model Number: secondary type cable
Insulation Material: no insulation
Type: Low Voltage
Application: Overhead
Conductor Material: Aluminum
Jacket: no sheath
Material: alloy aluminum
Mark: CCC, IEC
Standard: AWG, IEC, BS, ASTM
Using: Overhead, power transmission lines
Delivery Detail: Shipped in 15 days after payment
Packaging Detail: standard export wooden drums each end of cable shall be firmly and properly secured to drum for quadruplex abc cable
600 / 1000 volts 3x70mm2 1×54.6mm2 1x16mm2 abc cable with NF C 33-209 aerial bundled cable
 
Product Description

600 VOLT SECONDARY UD – DUPLEX / TRIPLEX / QUADRUPLEX

APPLICATION

Directly buried or installed in ducts for 600 volt secondary distribution.

PRODUCT FEATURES

Concentric stranded or compressed 1350-H19 aluminum conductor, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral, triple yellow striped or solid yellow. Black neutrals may be specified if desired.

STANDARDS

ASTM B-230, B-231 amd ICEA S-105-692 UL Standard 854 for Type USE-2
Federal Specification JC-30B NEC

 

HONGDA CABLE Duplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor

Code Word

Phase Conductors

Neutral Conductor

Single
Phase
Conductor
(in)

Outside
Diameter
(in)

Weight
per 1000 ft.
(lbs)

Ampacity

Size
AWG

Strand

Insulation Thickness
(MLS)

Size
AWG

Strand

Insulation Thickness
(MLS)

Direct Burial

In Duct

Bard

8

7/W

60

8

7/W

60

.262

.524

76

70

55

Clafin

6

7/W

60

6

7/W

60

.299

.596

91

95

70

Delgado

4

7/W

60

4

7/W

60

.345

.690

129

125

90

Everett

2

7/W

60

2

7/W

60

.403

.808

187

187

100

HONGDA CABLE Triplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor

Code Word

Phase Conductors

Neutral Conductor

Single
Phase
Conductor
(in)

Outside
Diameter
(in)

Weight
per 1000 ft
(lbs)

Ampacity

Size
AWG

Strand

Insulation Thickness
(MLS)

Size
AWG

Strand

Insulation Thickness
(MLS)

Direct Burial

In Duct

Erksine

6

7/w

60

6

7/w

60

.299

.646

143

95

70

Vassar

4

7/w

60

4

7/w

60

.345

.754

203

125

90

Stephens

2

7/w

60

4

7/w

60

.403

.842

264

165

120

Ramapo

2

7/w

60

2

7/w

60

.403

.874

294

165

120

Brenau

1/0

19/w

80

2

7/w

60

.522

1.064

408

215

160

Bergen

1/0

19/w

80

1/0

19/w

80

.522

1.133

465

215

160

Converse

2/0

19/w

80

1

19/w

80

.566

1.174

502

245

180

Hunter

2/0

19/w

80

2/0

19/w

80

.566

1.228

560

245

180

Hollins

3/0

19/w

80

1/0

19/w

80

.616

1.276

606

280

205

Sweetbriar

4/0

19/w

80

2/0

19/w

80

.672

1.389

739

315

240

Monmouth

4/0

19/w

80

4/0

19/w

80

.672

1.457

828

315

240

Pratt

250

37/w

95

3/0

19/w

80

.748

1.538

893

345

265

Wesleyan

350

37/w

95

4/0

19/w

80

.851

1.736

1166

415

320

Rider

500

37/w

95

350

37/w

95

.979

2.035

1663

495

395

Fairfield

750

61/w

110

500

37/w

95

1.118

2.860

2304

615

525

HONGDA CABLE Quadruplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor

Code Word

Phase Conductors

Neutral Conductor

Single
Phase
Conductor
(in)

Outside
Diameter
(in)

Weight
per 1000 ft
(lbs)

Ampacity

Size
AWG

Strand

Insulation Thickness
(MLS)

Size
AWG

Strand

Insulation Thickness
(MLS)

Direct Burial

In Duct

Tulsa

4

7/w

60

4

7/w

60

.345

.833

258

119

85

Dyke

2

7/w

60

4

7/w

60

.403

.938

346

153

115

Wittenberg

2

7/w

60

2

7/w

60

.403

.973

375

153

115

Notre Dame

1/0

19/w

80

2

7/w

60

.522

1.188

541

198

150

Purdue

1/0

19/w

80

1/0

19/w

80

.522

1.260

596

198

150

Syracuse

2/0

19/w

80

1

19/w

80

.566

1.316

664

225

170

Wake Forest

4/0

19/w

80

2/0

19/w

80

.672

1.560

979

290

225

Rust

250

37/w

95

3/0

19/w

80

.748

1.725

1,176

319

240

Slippery Rock

350

37/w

95

4/0

19/w

80

.851

1.945

1,544

385

305

Wofford

500

37/w

95

350

37/w

95

.851

2.348

2,174

467

420

Westminster

750

61/w

110

350

37/w

95

.979

2.722

2,816

615

492

Ampacity: 90°C conductor temperature, 20°C ambient, RHO 90, 100% load factor for three conductor triplex with neutral carrying only unbalanced load.
All Yellow Extruded Stripe, cable is XLP insulation.
* To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
The above data are approximate and subject to normal manufacturing tolerances.

 

 

Other cross-sections can be offered upon request.

 

Quadruplex Service Drop -Aluminum Conductor

Applications

Used as overhead cable to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

 

Triplex service drop -Aluminum Conductor

Applications

Used as overhead cable to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

 

Duplex Service Drop -Aluminum Conductor

Applications
Primarily used as overhead cable or air cable for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

 

Packaging & Shipping

 

 

Company Information

 

Why Choose Us

1. We have a large production base, and advanced production equipment 
2.  Have an competitive price and high quality
3.  Excellent after-sale service
4.  Attractive design and various styles
5.  Free issue:packaging list,invoice,CD installation
6.  Powerful technology R&D team
7.  Strict quality assurance system and perfect testing means
8.  Advanced process equipment
9.  Painted with powerful antiseptic Anticorrosion material paints
10. Delivery on  time
11. Our roller coaster sales to Middle East,Africa,Russia,Southeast Asia, etc.
12.We have a good reputation in the overseas

Contact Information
 

Contact information

 

If you can't find the product you need in the list, please contact me, and I will serve for you wholeheartedly !!!

We are looking forward to your inquiry and nice cooperaton.

 

Tags: , ,

Contact us

 

 

 

Search