Low voltage 0.6/1kv aerial service concentric abc cable (aerial bundle cable ) triplex service drop cable for 600v

Port: | Qingdao port for triplex service drop cable |
Payment Terms: | L/C,T/T,Western Union,MoneyGram |
Supply Ability: | 1600 Kilometer/Kilometers per Month triplex service drop cable |
Place of Origin: | Henan China |
Brand Name: | Hongda triplex service drop cable |
Model Number: | triplex service drop cable |
Insulation Material: | no insulation |
Type: | Low Voltage |
Application: | Overhead |
Conductor Material: | Aluminum |
Jacket: | no sheath |
Material: | alloy aluminum |
Mark: | CCC, IEC |
Standard: | AWG, IEC, BS, ASTM |
Using: | Overhead, power transmission lines |
Cable Type: | triplex service drop cable |
Conductor Type: | ACSR AAC AAAC ACAR |
Rated voltage: | 600/1000 Volts |
Insulation: | XLPE Insulation |
Packing: | Wooden Drum |
Core: | Multi-core |
Delivery Detail: | Shipped in 15 days after payment |
Packaging Detail: | standard export wooden drums each end of cable shall be firmly and properly secured to drum for triplex service drop cable |
600 VOLT SECONDARY UD – DUPLEX / TRIPLEX / QUADRUPLEX
APPLICATION
Directly buried or installed in ducts for 600 volt secondary distribution.
PRODUCT FEATURES
Concentric stranded or compressed 1350-H19 aluminum conductor, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral, triple yellow striped or solid yellow. Black neutrals may be specified if desired.
STANDARDS
ASTM B-230, B-231 amd ICEA S-105-692 UL Standard 854 for Type USE-2
Federal Specification JC-30B NEC
HONGDA CABLE Duplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor |
|||||||||||
Code Word |
Phase Conductors |
Neutral Conductor |
Single |
Outside |
Weight |
Ampacity |
|||||
Size |
Strand |
Insulation Thickness |
Size |
Strand |
Insulation Thickness |
Direct Burial |
In Duct |
||||
Bard |
8 |
7/W |
60 |
8 |
7/W |
60 |
.262 |
.524 |
76 |
70 |
55 |
Clafin |
6 |
7/W |
60 |
6 |
7/W |
60 |
.299 |
.596 |
91 |
95 |
70 |
Delgado |
4 |
7/W |
60 |
4 |
7/W |
60 |
.345 |
.690 |
129 |
125 |
90 |
Everett |
2 |
7/W |
60 |
2 |
7/W |
60 |
.403 |
.808 |
187 |
187 |
100 |
HONGDA CABLE Triplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor |
|||||||||||
Code Word |
Phase Conductors |
Neutral Conductor |
Single |
Outside |
Weight |
Ampacity |
|||||
Size |
Strand |
Insulation Thickness |
Size |
Strand |
Insulation Thickness |
Direct Burial |
In Duct |
||||
Erksine |
6 |
7/w |
60 |
6 |
7/w |
60 |
.299 |
.646 |
143 |
95 |
70 |
Vassar |
4 |
7/w |
60 |
4 |
7/w |
60 |
.345 |
.754 |
203 |
125 |
90 |
Stephens |
2 |
7/w |
60 |
4 |
7/w |
60 |
.403 |
.842 |
264 |
165 |
120 |
Ramapo |
2 |
7/w |
60 |
2 |
7/w |
60 |
.403 |
.874 |
294 |
165 |
120 |
Brenau |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
.522 |
1.064 |
408 |
215 |
160 |
Bergen |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.522 |
1.133 |
465 |
215 |
160 |
Converse |
2/0 |
19/w |
80 |
1 |
19/w |
80 |
.566 |
1.174 |
502 |
245 |
180 |
Hunter |
2/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.566 |
1.228 |
560 |
245 |
180 |
Hollins |
3/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.616 |
1.276 |
606 |
280 |
205 |
Sweetbriar |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.672 |
1.389 |
739 |
315 |
240 |
Monmouth |
4/0 |
19/w |
80 |
4/0 |
19/w |
80 |
.672 |
1.457 |
828 |
315 |
240 |
Pratt |
250 |
37/w |
95 |
3/0 |
19/w |
80 |
.748 |
1.538 |
893 |
345 |
265 |
Wesleyan |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
.851 |
1.736 |
1166 |
415 |
320 |
Rider |
500 |
37/w |
95 |
350 |
37/w |
95 |
.979 |
2.035 |
1663 |
495 |
395 |
Fairfield |
750 |
61/w |
110 |
500 |
37/w |
95 |
1.118 |
2.860 |
2304 |
615 |
525 |
HONGDA CABLE Quadruplex Conductor 600 Volt Secondary Type URD Cable – Aluminum Conductor |
|||||||||||
Code Word |
Phase Conductors |
Neutral Conductor |
Single |
Outside |
Weight |
Ampacity |
|||||
Size |
Strand |
Insulation Thickness |
Size |
Strand |
Insulation Thickness |
Direct Burial |
In Duct |
||||
Tulsa |
4 |
7/w |
60 |
4 |
7/w |
60 |
.345 |
.833 |
258 |
119 |
85 |
Dyke |
2 |
7/w |
60 |
4 |
7/w |
60 |
.403 |
.938 |
346 |
153 |
115 |
Wittenberg |
2 |
7/w |
60 |
2 |
7/w |
60 |
.403 |
.973 |
375 |
153 |
115 |
Notre Dame |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
.522 |
1.188 |
541 |
198 |
150 |
Purdue |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.522 |
1.260 |
596 |
198 |
150 |
Syracuse |
2/0 |
19/w |
80 |
1 |
19/w |
80 |
.566 |
1.316 |
664 |
225 |
170 |
Wake Forest |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.672 |
1.560 |
979 |
290 |
225 |
Rust |
250 |
37/w |
95 |
3/0 |
19/w |
80 |
.748 |
1.725 |
1,176 |
319 |
240 |
Slippery Rock |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
.851 |
1.945 |
1,544 |
385 |
305 |
Wofford |
500 |
37/w |
95 |
350 |
37/w |
95 |
.851 |
2.348 |
2,174 |
467 |
420 |
Westminster |
750 |
61/w |
110 |
350 |
37/w |
95 |
.979 |
2.722 |
2,816 |
615 |
492 |
Ampacity: 90°C conductor temperature, 20°C ambient, RHO 90, 100% load factor for three conductor triplex with neutral carrying only unbalanced load.
All Yellow Extruded Stripe, cable is XLP insulation.
* To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
The above data are approximate and subject to normal manufacturing tolerances.
Other cross-sections can be offered upon request.
Quadruplex Service Drop -Aluminum Conductor
Applications
Used as overhead cable to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
Triplex service drop -Aluminum Conductor
Applications
Used as overhead cable to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
Duplex Service Drop -Aluminum Conductor
Applications
Primarily used as overhead cable or air cable for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
1. We have a large production base, and advanced production equipment
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Attractive design and various styles
5. Free issue:packaging list,invoice,CD installation
6. Powerful technology R&D team
7. Strict quality assurance system and perfect testing means
8. Advanced process equipment
9. Painted with powerful antiseptic Anticorrosion material paints
10. Delivery on time
11. Our roller coaster sales to Middle East,Africa,Russia,Southeast Asia, etc.
12.We have a good reputation in the overseas
Contact information
If you can't find the product you need in the list, please contact me, and I will serve for you wholeheartedly !!!
We are looking forward to your inquiry and nice cooperaton.
- Next: Medium voltage 150mm2 xlpe cable with aluminum wire 33kV XLPE Insulated Aerial Bundle Cable
- Previous: Low voltage 0.6/1kv 600V Quadruplex Aluminum Conductor URD cable