600V Aluminum or copper Service Entrance Type SER Cable 4AWG 2AWG 1/0AWG 2/0AWG
Aluminum Copper SER Service Entrance TYPE R Cable Specification:
Aluminum copper SER cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90°C in wet locations. Voltage rating is 600 volts.
Conductors:
Aluminum copper SER cable has a compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801
Insulation:
Aluminum copper SER cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare copper ground and covered with a reinforced binder tape. For color code, see table B in technical section.
Jacket:
Aluminum copper SER cable has a gray sunlight resistance polyvinyl chloride (PVC) jacket.
Standards:
- Ampacities based on National Electric Code, 2005 edition, section 310-15
- 60°C when terminated to equipment for circuits rated 100amps or less or marked for 14ga through 1ga conductors
- 70°C when terminated to equipment for circuits rated over 100amps or marked for conductors larger than 1ga
- 90°C wet or dry locations
- For dwelling units, conductors shall be permitted at listed Ampacities to be utilized as 120/240 volt, 3-wire, single phase service
- conductors that supply the total load
- UL 44
For more specifcation of PVC PE XLPE Insulated Cable pls email me (sale04(at)zzhongdacable.com.cn) or call me Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725
|
Service Entrance Cable Style R (SER) – 2 Conductor with Ground SER |
||||||
|
Size AWG & Construction |
Stranding |
Nominal Diameter (in) |
Weight per 1000 ft. (lbs) |
Ampacity (AMPS) * |
||
|
Phase |
Equipment Ground Conductor |
90° C |
Dwelling |
|||
|
6-6-6 |
7 |
– |
.650 |
150 |
60 |
– |
|
4-4-6 |
7 |
– |
.681 |
196 |
75 |
– |
|
4-4-4 |
7 |
– |
.682 |
196 |
75 |
– |
Notes: Data are approximate and subject to normal manufacturing tolerances.
* To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
|
Service Entrance Cable Style R (SER) – 3 Conductor with Ground SER |
||||||
|
Size AWG & Construction |
Stranding |
Nominal Diameter (in) |
Weight per 1000 ft. (lbs) |
Ampacity (AMPS) * |
||
|
Phase |
Equipment Ground Conductor |
90° C |
Dwelling |
|||
|
8-8-8-8 |
Solid |
Solid |
.588 |
128 |
45 |
– |
|
6-6-6-6 |
7 |
7 |
.684 |
180 |
60 |
– |
|
4-4-4-6 |
7 |
7 |
.754 |
240 |
75 |
– |
|
2-2-2-4 |
7 |
7 |
.893 |
344 |
100 |
100 |
|
1-1-1-3 |
19 |
7 |
1.003 |
432 |
115 |
110 |
|
1/0-1/0-1/0-2 |
19 |
7 |
1.097 |
521 |
135 |
125 |
|
2/0-2/0-2/0-1 |
19 |
19 |
1.197 |
633 |
150 |
150 |
|
3/0-3/0-3/0-1/0 |
19 |
19 |
1.314 |
771 |
175 |
175 |
|
4/0-4/0-4/0-2/0 |
19 |
19 |
1.443 |
942 |
205 |
200 |
|
250-250-250-3/0 |
37 |
19 |
1.601 |
1106 |
230 |
225 |
|
Service Entrance Cable Style R (SER) – 4 Conductor with Ground SER |
||||||
|
Size AWG & Construction |
Stranding |
Nominal Diameter (in) |
Weight per 1000 ft. (lbs) |
Ampacity (AMPS) * |
||
|
Phase |
Equipment Ground Conductor |
90° C |
Dwelling |
|||
|
2-2-2-2-4 |
7 |
7 |
1.004 |
450 |
100 |
100 |
|
2/0-2/0-2/0-2/0-1 |
19 |
19 |
1.346 |
824 |
150 |
150 |
|
4/0-4/0-4/0-4/0-2/0 |
19 |
19 |
1.621 |
1226 |
205 |
200 |
|
250-250-250-250-3/0 |
37 |
19 |
1.950 |
1454 |
230 |
225 |
Notes: Data are approximate and subject to normal manufacturing tolerances.
* To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
600V Aluminum or copper Service Entrance Type SER Cable 4AWG 2AWG 1/0AWG 2/0AWG
Aluminum SER Service Entrance TYPE R Cable Application:
What is SER Cable?
Service Entrance cable with Reinforcement tape
What is SEU Cable?
Service Entrance cable, Underground
Aluminum copper SER / SEU Cable Applications:
-SER cable is used as an above ground service entrance cable, a panel feeder and in branch circuits. The cable is rated at 600 volts and 90°C for use in wet and dry locations. SER cables are LEAD FREE and RoHS compliant.
-SEU cable is primarily used underground as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90°C in wet locations. Voltage rating is 600 volts.
Aluminum copper SER / SEU Cable Construction:
Conductor – Compact stranded AA-8000 series aluminum alloy (ACM) per ASTM B801 or B836. Features solid AA-8000 series aluminum alloy (ACM) per ASTM B800.
Insulation – Color coded cross-linked polyethylene (XLPE).
Assembly – Insulated conductors are cabled with the bare ground wire. A flame retardant fiberglass reinforced binder tape assembles the core in a circular configuration.
Jacket – Sunlight resistant, LEAD FREE, flame retardant, gray polyvinyl chloride (PVC) material.
Aluminum copper SER / SEU Cable Standards:
Meets UL 854 Service Entrance Cable
Certifications:
Company Profile
Hongda cable Co., Ltd. is one of the most professional cable & wire producer under modern enterprise system in China, which was founded in 1988, integrating scientific research, development, production and sales. The company mainly produces 1-35 kV power cable, ABC cable, AAC, AAAC, ACSR.
Our advantages
1. With more than 17 years manufacturing experience, our products are strictly in accordance with ISO, CE, UL and BV;
2. Good cost-control system, with highly-competitive prices;
3. Strong and Professional R&D team to meet your specific needs;
4. Fast delivery&reliable products are always the reason why you choose us.
Contact information
Any needs or question ,please contact us ,we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperaton.