2AWG 1/0AWG 2/0AWG quadruplex service drop wire Overhead ABC Cable with bare AAC conductor

Port: | QINGDAO SHANGHAI |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 1200 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | HONGDA |
Model Number: | 2AWG MUSTANG |
Type: | Insulated |
Application: | Overhead |
Conductor Material: | Aluminum |
Conductor Type: | Stranded |
Insulation Material: | PVC |
Product name: | 2AWG MUSTANG quadruplex service drop wire Overhead ABC Cable |
Colour: | Black or as your request |
Conductor Material: | aluminum or copper cable |
Conductor Type: | Stranded |
MODEL MUNBER: | 600/1000V aluminum cable |
application: | overhead power transmission use ABC cable |
voltage: | 0.6/1kv ABC overhead cable |
insulation: | PVC PE XLPE |
Certification: | ISO9001 |
Standard: | ASTM |
Packaging Detail: | 2AWG MUSTANG quadruplex service drop wire Overhead ABC Cable with bare AAC conductor packed in wooden drum |
2AWG 1/0AWG 2/0AWG quadruplex service drop wire Overhead ABC Cable with bare AAC conductor
we are a professional manufacturer of Overhead ABC Cable,We have the best R&D, production, sales and service team and modern enterprise management organization.
Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE / PE / PVC / LDPE insulation, Aluminum Conductor
Product Description
1. Application of Service Drop Cable:
Service Drop Cable (ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detailed Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower ATA conductor temperature of 750C maximum.
Construction
Concentric stranded or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Code Word |
Phase conductor |
Bare Neutral Messenger |
Nominal Lay Length |
Weight Per 1000ft. (lbs.) |
Allowable Ampacities+ |
|||||||
Size (AWG) |
Stranding |
Insul. Thick. (Mils) |
Size (AWG) |
Stranding |
Rated Strength (lbs.) |
inches |
XLP |
POLY |
XLP |
POLY |
||
AAC Neutral-messenger |
||||||||||||
Pekingese |
6 |
1 |
45 |
6 |
7 |
563 |
10.36 |
61 |
61 |
85 |
70 |
|
Collie |
6 |
7 |
45 |
6 |
7 |
563 |
10.36 |
64 |
64 |
85 |
70 |
|
Dachshund |
4 |
1 |
45 |
4 |
7 |
881 |
10.36 |
92 |
92 |
115 |
90 |
|
Spaniel |
4 |
7 |
45 |
4 |
7 |
881 |
10.36 |
96 |
96 |
115 |
90 |
|
Doberman |
2 |
7 |
45 |
2 |
7 |
1350 |
14.88 |
147 |
147 |
150 |
120 |
|
Malemute |
1/0 |
9 |
60 |
1/0 |
7 |
1990 |
14.88 |
234 |
234 |
205 |
160 |
|
|
|
|
|
|
|
|
|
|
|
|
|
3.2 Triplex Service Drop
Applications
To supply power from the utility`s lines to the consumer`s weather head. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Code Name |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000ft (lbs) |
Ampacity(amps) |
||||||
Size AWG |
Stranding |
Insulation Thickness(mls) |
Size AWG |
Stranding |
Breaking Strength(lbs) |
XLPE |
Poly |
XLPE |
Poly |
|
6201 ALLOY NEUTRAL-MESSENGER |
||||||||||
Minex |
6 |
Solid |
45 |
6 |
7 |
1,110 |
106.6 |
102.9 |
85 |
70 |
Hippa |
6 |
7 |
45 |
6 |
7 |
1,110 |
113.2 |
105.7 |
85 |
70 |
Prawn |
4 |
Solid |
45 |
4 |
7 |
1,760 |
158.4 |
154.1 |
115 |
90 |
Barnacles |
4 |
7 |
45 |
4 |
7 |
1,760 |
168.3 |
158.2 |
115 |
90 |
Shrimp |
2 |
7 |
45 |
2 |
7 |
2,800 |
253.7 |
239.7 |
150 |
120 |
Gammarus |
1/0 |
7 |
60 |
1/0 |
7 |
4,460 |
411.7 |
386.0 |
205 |
160 |
Leda |
1/0 |
19 |
60 |
1/0 |
7 |
4,460 |
402.7 |
386.0 |
205 |
160 |
Dungenese |
2/0 |
7 |
60 |
2/0 |
7 |
5,390 |
506.8 |
476.3 |
235 |
185 |
Cyclops |
2/0 |
19 |
60 |
2/0 |
7 |
5,390 |
495.3 |
476.3 |
235 |
185 |
Dlustra |
3/0 |
19 |
60 |
3/0 |
7 |
6,790 |
611.4 |
589.1 |
275 |
215 |
Lepas |
4/0 |
19 |
60 |
4/0 |
7 |
8,560 |
757.1 |
730.5 |
315 |
245 |
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR.
Code*Word |
Phase conductor |
Bare Neutral Message |
Nominal lay Length |
Weight Per |
Allo wable Amp acitles |
||||||
Size |
Stranding |
Insul |
Size |
Stranding |
Rated |
inches |
XLP |
POLY |
XLP |
POLY |
|
AAC Neutral-messenger |
|||||||||||
Clydessdale |
4 |
1 |
45 |
4 |
7 |
881 |
20.58 |
198 |
198 |
100 |
80 |
Pinto |
4 |
7 |
45 |
4 |
7 |
881 |
20.58 |
211 |
211 |
100 |
80 |
Mustang |
2 |
7 |
45 |
2 |
7 |
1350 |
25.42 |
318 |
318 |
135 |
105 |
Criollo |
1/0 |
9 |
60 |
1/0 |
7 |
1990 |
25.42 |
503 |
503 |
180 |
140 |
Percheron |
2/0 |
11 |
60 |
2/0 |
7 |
2510 |
29.97 |
619 |
619 |
205 |
160 |
Hanovarian |
3/0 |
17 |
60 |
3/0 |
19 |
3310 |
35.18 |
764 |
764 |
235 |
185 |
Oldenburg |
4/0 |
18 |
60 |
4/0 |
19 |
4020 |
35.18 |
945 |
945 |
275 |
210 |
Lippizaner |
336.4 |
19 |
80 |
336.4 |
19 |
6146 |
38.79 |
1519 |
1519 |
370 |
280 |
|
Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Contact information
Any needs or question ,please contact us ,we will be more pleasure to service you.
Skype ID: yang.lubing
Cellphone/WhatsApp/Wechat: +86 13783451632
We are looking forward to your inquiry and nice cooperaton.
- Next: 4*25mm2 16mm2 4 Core Copper 0.6/1kv CU/PVC/SWA/PVC Armoured Power Cable
- Previous: Earth Wire OPGW Cable Manufacturer 12 Core Single Mode Fiber Optic Cable
Contact us
Search
You May Like
- No related articles