0.6/1kv CU XLPE LSZH SWA LSZH Insulated 16mm2 Cable

Port: | Qingdao or Shanghai or Shengzhen |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 500 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | CU XLPE LSZH SWA LSZH |
Insulation Material: | XLPE |
Type: | Low Voltage |
Application: | Underground |
Conductor Material: | Copper |
Jacket: | LSZH |
Product name: | 0.6/1kv CU XLPE LSZH SWA LSZH Insulated 16mm2 Cable |
Conductor: | Pure Copper |
Insulation: | XLPE Insulation |
Rated voltage: | 0.6/1KV |
Standard: | BS6724 |
Certificate: | ISO9001 |
Delivery Detail: | Shipped in 15 days after payment |
Packaging Detail: | In coil or wooden drum |
BS 6724 Armoured Power Cables, 600/1000V
Applications
These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The GSWA makes them suitable for use inside and outside buildings or for direct burial in the ground. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Construction
Conductor | Solid Aluminum or Copper conductor, round stranded or shaped, Class 2 to BS 6460, IEC 60228. |
---|---|
Insulation | XLPE (Cross-Linked Polyethylene) Type GP 8 or ethylene propylene rubber (GP 6) |
Colour Code | 1 Core : Brown |
2 Cores: Brown or Blue | |
3 Cores: Brown, Black, Grey | |
4 Cores: Blue, Brown, Black, Grey | |
5 Cores: Green-yellow, Blue, Brown, Black, Grey | |
Above 5 Cores: White Cores with black numbers | |
Bedding | LSOH (Low Smoke Zero Halogen) |
Armour | Single Core: AWA (Aluminum Wire Armour) |
Multi Core: SWA (Steel Wire Armour) | |
Outer Sheath | LSOH (Low Smoke Zero Halogen) |
Technical Information
Voltage rating | 600/1000V |
---|---|
Temperature rating | 0°C to + 90°C |
Bending radius | 1.5mm² to 16mm² : 6 x overall diameter |
25mm² and above : 8 x overall diameter | |
Flame retardant | IEC60332 part 1, BS4066 part 1 |
Halogen free | IEC 60754, EN 50267 |
Smoke density | IEC 61034, EN50268 |
Cable Parameter
Nominal Cross-sectional Area | Strand Type | Nominal Insulation Thickness | Nominal Bedding Thickness | Nominal Alum Wire Armor dia. | Nominal Sheath Thickness | Approx. Overall Diameter | Aprrox Weight |
---|---|---|---|---|---|---|---|
mm² | No./mm | mm | mm | mm | mm | mm | kg/km |
1×50 | 19/1.78 | 1.0 | 0.8 | 0.9 | 1.5 | 17.5 | 800 |
1×70 | 19/2.14 | 1.1 | 0.8 | 1.25 | 1.5 | 20.2 | 990 |
1×95 | 19/2.52 | 1.1 | 0.8 | 1.25 | 1.6 | 22.3 | 1280 |
1×120 | 37/2.03 | 1.2 | 0.8 | 1.25 | 1.6 | 24.2 | 1550 |
1×150 | 37/2.25 | 1.4 | 1 | 1.6 | 1.7 | 27.4 | 1900 |
1×185 | 37/2.52 | 1.6 | 1 | 1.6 | 1.8 | 30.0 | 2320 |
1×240 | 61/2.25 | 1.7 | 1 | 1.6 | 1.8 | 32.8 | 2930 |
1×300 | 61/2.52 | 1.8 | 1 | 1.6 | 1.9 | 35.6 | 3580 |
1×400 | 61/2.85 | 2.0 | 1.2 | 2.0 | 2.0 | 40.5 | 4600 |
1×500 | 61/3.20 | 2.2 | 1.2 | 2.0 | 2.1 | 44.2 | 5680 |
1×630 | 127/2.52 | 2.4 | 1.2 | 2.0 | 2.2 | 48.8 | 7160 |
1×800 | 127/2.85 | 2.6 | 1.4 | 2.5 | 2.4 | 55.4 | 9315 |
1×1000 | 127/3.20 | 2.8 | 1.4 | 2.5 | 2.5 | 60.6 | 11490 |
Nominal Cross-sectional Area | Strand Type | Nominal Insulation Thickness | Nominal Bedding Thickness | Nominal Steel Wire Armor dia. | Nominal Sheath Thickness | Approx. Overall Diameter | Aprrox Weight |
---|---|---|---|---|---|---|---|
mm² | No./mm | mm | mm | mm | mm | mm | kg/km |
2×1.5 | 7/0.53 | 0.6 | 0.8 | 0.9 | 1.4 | 12.1 | 320 |
2×2.5 | 7/0.67 | 0.7 | 0.8 | 0.9 | 1.4 | 13.6 | 365 |
2×4 | 7/0.85 | 0.7 | 0.8 | 0.9 | 1.4 | 14.7 | 440 |
2×6 | 7/1.04 | 0.7 | 0.8 | 0.9 | 1.4 | 15.9 | 470 |
2×10 | 7/1.35 | 0.7 | 0.8 | 0.9 | 1.5 | 18.0 | 800 |
2×16 | 7/1.70 | 0.7 | 0.8 | 1.25 | 1.5 | 20.4 | 900 |
2×25 | 7/2.14 | 0.9 | 0.8 | 1.25 | 1.6 | 24.1 | 1240 |
2×25* | 7/2.14 | 0.9 | 0.8 | 1.25 | 1.6 | 20.4 | 1240 |
2×35 | 7/2.52 | 0.9 | 1 | 1.6 | 1.7 | 27.7 | 1710 |
2×35* | 7/2.52 | 0.9 | 1 | 1.6 | 1.7 | 23.3 | 1710 |
2×50* | 19/1.78 | 1.0 | 1 | 1.6 | 1.8 | 25.8 | 1800 |
2×70* | 19/2.14 | 1.1 | 1 | 1.6 | 1.9 | 29.0 | 2320 |
2×95* | 19/2.52 | 1.1 | 1.2 | 2.0 | 2.0 | 33.0 | 3150 |
2×120* | 37/2.03 | 1.2 | 1.2 | 2.0 | 2.1 | 36.1 | 3880 |
2×150* | 37/2.25 | 1.4 | 1.2 | 2.0 | 2.2 | 39.3 | 4820 |
2×185* | 37/2.52 | 1.6 | 1.4 | 2.5 | 2.4 | 44.7 | 5920 |
2×240* | 61/2.25 | 1.7 | 1.4 | 2.5 | 2.5 | 49.0 | 7300 |
2×300* | 61/2.52 | 1.8 | 1.6 | 2.5 | 2.6 | 53.5 | 8770 |
2×400* | 61/2.85 | 2 | 1.6 | 2.5 | 2.8 | 59.0 | 10905 |
* D-Shaped stranded conductor (class 2)
Nominal Cross-sectional Area | Strand Type | Nominal Insulation Thickness | Nominal Bedding Thickness | Nominal Steel Wire Armor dia. | Nominal Sheath Thickness | Approx. Overall Diameter | Aprrox Weight |
---|---|---|---|---|---|---|---|
mm² | No./mm | mm | mm | mm | mm | mm | kg/km |
3×1.5 | 7/0.53 | 0.6 | 0.8 | 0.9 | 1.3 | 12.6 | 340 |
3×2.5 | 7/0.67 | 0.7 | 0.8 | 0.9 | 1.4 | 14.1 | 408 |
3×4 | 7/0.85 | 0.7 | 0.8 | 0.9 | 1.4 | 15.3 | 498 |
3×6 | 7/1.04 | 0.7 | 0.8 | 0.9 | 1.4 | 16.6 | 600 |
3×10 | 7/1.35 | 0.7 | 0.8 | 1.25 | 1.5 | 19.5 | 915 |
3×16 | 7/1.70 | 0.7 | 0.8 | 1.25 | 1.6 | 21.6 | 1130 |
3×25 | 7/2.14 | 0.9 | 1 | 1.6 | 1.7 | 26.7 | 1710 |
3×25* | 7/2.14 | 0.9 | 1 | 1.6 | 1.7 | 23.6 | 1710 |
3×35 | 7/2.52 | 0.9 | 1 | 1.6 | 1.8 | 29.4 | 2100 |
3×35* | 7/2.52 | 0.9 | 1 | 1.6 | 1.8 | 25.7 | 2100 |
3×50* | 19/1.78 | 1.0 | 1 | 1.6 | 1.8 | 28.5 | 2450 |
3×70* | 19/2.14 | 1.1 | 1 | 1.6 | 1.9 | 32.2 | 3120 |
3×95* | 19/2.52 | 1.1 | 1.2 | 2.0 | 2.1 | 37.0 | 4310 |
3×120* | 37/2.03 | 1.2 | 1.2 | 2.0 | 2.2 | 40.4 | 5160 |
3×150* | 37/2.25 | 1.4 | 1.4 | 2.5 | 2.3 | 45.5 | 7160 |
3×185* | 37/2.52 | 1.6 | 1.4 | 2.5 | 2.4 | 49.8 | 8600 |
3×240* | 61/2.25 | 1.7 | 1.4 | 2.5 | 2.6 | 55.1 | 10755 |
3×300* | 61/2.52 | 1.8 | 1.6 | 2.5 | 2.7 | 60.2 | 13080 |
3×400* | 61/2.85 | 2 | 1.6 | 2.5 | 2.9 | 66.6 | 15810 |
*Shaped stranded conductor (class 2)
Nominal Cross-sectional Area | Strand Type | Nominal Insulation Thickness | Nominal Bedding Thickness | Nominal Steel Wire Armor dia. | Nominal Sheath Thickness | Approx. Overall Diameter | Aprrox Weight |
---|---|---|---|---|---|---|---|
mm² | No./mm | mm | mm | mm | mm | mm | kg/km |
4×1.5 | 7/0.53 | 0.7 | 0.8 | 0.9 | 1.4 | 13.3 | 390 |
4×2.5 | 7/0.67 | 0.7 | 0.8 | 0.9 | 1.4 | 15.0 | 470 |
4×4 | 7/0.85 | 0.7 | 0.8 | 0.9 | 1.4 | 16.4 | 580 |
4×6 | 7/1.04 | 0.7 | 0.8 | 1.25 | 1.5 | 18.7 | 805 |
4×10 | 7/1.35 | 0.7 | 0.8 | 1.25 | 1.5 | 21.1 | 1090 |
4×16 | 7/1.70 | 0.7 | 0.8 | 1.25 | 1.6 | 23.4 | 1320 |
4×25 | 7/2.14 | 0.9 | 1 | 1.6 | 1.7 | 28.9 | 1840 |
4×25* | 7/2.14 | 0.9 | 1 | 1.6 | 1.7 | 26.1 | 1840 |
4×35 | 7/2.52 | 0.9 | 1 | 1.6 | 1.8 | 31.9 | 2310 |
4×35* | 7/2.52 | 0.9 | 1 | 1.6 | 1.8 | 28.6 | 2310 |
4×50* | 19/1.78 | 1.0 | 1 | 1.6 | 1.9 | 32.0 | 2970 |
4×70* | 19/2.14 | 1.1 | 1.2 | 2.0 | 2.1 | 37.7 | 4240 |
4×95* | 19/2.52 | 1.1 | 1.2 | 2.0 | 2.2 | 41.7 | 5400 |
4×120* | 37/2.03 | 1.2 | 1.4 | 2.5 | 2.3 | 47.1 | 7000 |
4×150* | 37/2.25 | 1.4 | 1.4 | 2.5 | 2.4 | 51.4 | 8350 |
4×185* | 37/2.52 | 1.6 | 1.4 | 2.5 | 2.6 | 56.6 | 10130 |
4×240* | 61/2.25 | 1.7 | 1.6 | 2.5 | 2.7 | 63.0 | 12840 |
4×300* | 61/2.52 | 1.8 | 1.6 | 2.5 | 2.9 | 68.8 | 15530 |
4×400* | 61/2.85 | 2 | 1.8 | 3.15 | 3.2 | 78.1 | 19950 |
* Shaped stranded conductor (class 2)
Zhengzhou Hongda Cable Co., Ltd.
Established Year: 1999
Registered capital :RMB:5,000,000
Factory Area:300,000m2
Main products:
Areial bundle cable ,XLPE insulated power cable ,PVC insulated power cable ,electrical wire ,bare aluminum conductor(AAC AAAC ACSR )and so on
Main export county:
USA Philippines Malaysia Indonesia Venezuela, Colombia Mexico
Dominica India South Africa Zambia Kenya and so on .
As you know there are so many cable manufacture, we are one of the biggest manufacture in china-mainland. We will give you a perfect shopping experience . If you need visit our factory , we will meet you at the airport or train station.
Also we can offer other service
Custom Merchandise:we can make cable as your need include the color ,size and so on.we also offer OEM .
Complete Course Tracking:we can offer you the service from the business begin to you get the cable and use it .
Cable sample : we can offer the sample free
Q: Are you trading company or manufacturer ?
A: We are factory.
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.