djypv dyjpvp zr-dyjpvp Multicore Instrument cable
Port: | QINGDAO/SHANGHAI |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 1800 Kilometer/Kilometers per Month instrument cable |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | instrument cable |
Shielding: | Braid |
Conductor Material: | Copper |
Jacket: | PVC |
Insulation Material: | XLPE |
Color: | Red/yellow/green/blue or as your request |
Application Places: | Cable Ducts |
Properties: | High safety & competitive price |
Standard: | CCC/ BS /ASTM /GB |
Voltage: | Low voltage |
Core: | 2cores 3cores 4 cores 5cores to 60cores |
Size: | 1.5mm2 to 16mm2 |
Conductor: | Flexible Copper Wire / Stranded copper wire |
Insulation: | PE / PVC |
Armored Type: | Copper Braided Screen instrument cable |
Packaging Detail: | instrument cable is adopt for export wooden drum, wooden iron drum or other export standard package. We can also pack it according to your requirement. |
djypv dyjpvp zr-dyjpvp Multicore Instrument cable
Individual and Overall Screened Instrumentation Cables – Pairs, XLPE Insulation, PVC Jacket
Applications
- Transmission of analog or digital signals designed for process control
- For indoor and outdoor
- Dry or humid hot environment
Standards
- IEN 50228-7 (superseding BS 5308)
- IEC 60228
- IEN 60290-2-29
- IEN 60290-2-22
Construction
Conductor |
Stranded bare copper per IEC 60228 |
|
Insulation |
XLPE per EN 50290-2-29. Thickness per EN 50288-7, 500 V rating |
|
Pairs |
Two insulated wires twisted into pairs |
3 |
Communication Wire |
22# stranded tinned copper, XLPE insulation |
7 |
Color Code |
Black/white numbered, orange communication wire |
|
Individual Screening |
Each pair is screened with a polyester/aluminum (AL/PET) foil |
5 |
Pair Drain Wire |
Stranded tinned copper |
4 |
Cabling |
Pairs and communication wire are cabled into a cable core and wrapped in a PET tape |
|
Overall Screening |
Polyester/aluminum (AL/PET) foil |
6 |
Drain wire |
Stranded tinned copper |
2 |
Jacket |
Black UV-resistant FR-PVC per EN 60290-2-22 |
1 |
Printing |
DCC Instrumentation Cable, Nx2xG#, Ind. Screened, 90C XLPE, PVC-FR, IEC 60332-3, RoHS, Batch-code, Length in m, where N is the number of pairs and G is the conductor gage value |
|
Rating
- Operating temperature range -30°C to 90°C
- 80 V, 90°C
- Fire retardancy per IEC 60332-3C
- Bending radius £ 7.5 D (D = cable diameter)
Electrical Properties (20°C (
|
20AWG |
18AWG |
16AWG |
DC resistance |
£ 36 W/km |
£ 24.5 W/km |
£ 13.9 W/km |
Mutual capacitance |
£ 100 nF/km |
||
Capacitance unbalance |
£ 0.5 nF/500m |
||
L/R ratio |
£ 25 mH/W |
£ 25 mH/W |
£ 40 mH/W |
Current load |
£ 6 A |
£ 13 A |
£ 18 A |
Insulation resistance |
³ 5000 MW*km |
||
Dielectric strength |
Core-core: 2000 VAC /1 min |
Cable Codes and Technical Parameters
No. Pairs |
DCC Cable Code |
DCC PN |
Nominal Diameter(mm) |
Nominal Weight(kg/km) |
||
20AWG (~0.5 mm2) |
||||||
2 |
2*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28050 |
9.1 |
88 |
||
4 |
4*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28060 |
10.6 |
127 |
||
6 |
6*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28070 |
13.0 |
180 |
||
8 |
8*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28080 |
14.1 |
212 |
||
10 |
10*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28090 |
16.5 |
260 |
||
12 |
12*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28100 |
17.2 |
288 |
||
16 |
16*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28110 |
19.3 |
385 |
||
20 |
20*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28120 |
21.4 |
460 |
||
24 |
24*2*20#BS-C-ET/+22#TS-XP-C-V-ET |
RST28130 |
24.0 |
545 |
||
18AWG (~0.75 mm2) |
||||||
2 |
2*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28140 |
9.8 |
107 |
||
4 |
4*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28150 |
11.6 |
140 |
||
6 |
6*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28160 |
14.1 |
224 |
||
8 |
8*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28170 |
15.2 |
260 |
||
10 |
10*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28180 |
18.1 |
318 |
||
12 |
12*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28190 |
18.7 |
382 |
||
16 |
16*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28200 |
21.1 |
480 |
||
20 |
20*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28210 |
23.5 |
578 |
||
24 |
24*2*18#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28220 |
26.3 |
700 |
||
16AWG (~1.3 mm2) |
||||||
2 |
2*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28230 |
11.5 |
140 |
||
4 |
4*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28240 |
13.3 |
210 |
||
6 |
6*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28250 |
16.4 |
300 |
||
8 |
8*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28260 |
17.8 |
370 |
||
10 |
10*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28270 |
22.1 |
465 |
||
12 |
12*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28280 |
22.0 |
510 |
||
16 |
16*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28290 |
24.7 |
705 |
||
20 |
20*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28300 |
27.6 |
910 |
||
24 |
24*2*16#BS-C-ET/+1*22#TS-XP-C-V-ET |
RST28310 |
31.0 |
1010 |
||
Multipair Individual/overall Screen with Armor and Lead Sheath
Application:
These cable can be used in cable tray or conduit to connect different types of thermocouple in industrial process controls, refineries, oil and gas plant. Excellent protection against corrosion, humidity and poor vibration resistance.
Specification:
Conductor | Solid |
Type applicable | KX, EX, JX, TX, NX, KCA, KCB, RCA, RCB, SCA, RCB, BC |
Insulation | PVC, PE, XLPE or LSZH thermoplastic material |
Individual screen | 24 μm aluminium / PETP tape over solid tinned copper drain wire, 0.6 mm |
Wrapping | At least 1 layer of plastic tape |
Overall screen | 24 μm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm² |
Bedding | PE, PVC or LSZH thermoplastic material |
Lead sheath | Lead alloy |
Inner sheath | PVC or LSZH thermoplastic material |
Armor | Galvanized round steel wires |
Outer sheath | PVC or LSZH thermoplastic material |
Color code | According to IEC 60584-3 |
Flame retardancy | IEC 60332-1 |
Flame propagation | IEC 60332 cat. C |
Temperature range | -30°C up to 70°C during operation. -5°C up to 50°C during installation |
0.5 mm² :
No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Lead Sheath Thickness (mm) | Inner Sheath Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
2 | 0.4 | 0.9 | 1.1 | 0.8 | 0.9 | 1.4 | 17.3 | 892 |
4 | 0.4 | 1.1 | 1.1 | 0.8 | 0.9 | 1.4 | 18.9 | 1078 |
6 | 0.4 | 1.2 | 1.1 | 0.8 | 0.9 | 1.5 | 21.2 | 1309 |
8 | 0.4 | 1.2 | 1.2 | 0.8 | 0.9 | 1.5 | 22.3 | 1491 |
10 | 0.4 | 1.2 | 1.2 | 0.8 | 1.25 | 1.6 | 25.4 | 1912 |
12 | 0.4 | 1.2 | 1.2 | 0.9 | 1.25 | 1.6 | 25.8 | 2000 |
16 | 0.4 | 1.3 | 1.3 | 0.9 | 1.25 | 1.7 | 28.2 | 2383 |
20 | 0.4 | 1.3 | 1.3 | 0.9 | 1.25 | 1.7 | 29.5 | 2610 |
24 | 0.4 | 1.3 | 1.4 | 1.0 | 1.25 | 1.8 | 32.6 | 3087 |
0.8 mm² :
No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Lead Sheath Thickness (mm) | Inner Sheath Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
2 | 0.4 | 0.9 | 1.1 | 0.8 | 0.9 | 1.4 | 18.0 | 970 |
4 | 0.4 | 1.1 | 1.1 | 0.8 | 0.9 | 1.5 | 20.2 | 1204 |
6 | 0.4 | 1.2 | 1.1 | 0.8 | 0.9 | 1.5 | 22.3 | 1451 |
8 | 0.4 | 1.2 | 1.2 | 0.8 | 0.9 | 1.6 | 24.6 | 1848 |
10 | 0.4 | 1.2 | 1.2 | 0.9 | 1.25 | 1.6 | 26.9 | 2137 |
12 | 0.4 | 1.3 | 1.3 | 0.9 | 1.25 | 1.7 | 28.2 | 2383 |
16 | 0.4 | 1.3 | 1.3 | 0.9 | 1.25 | 1.7 | 30.0 | 2690 |
20 | 0.4 | 1.3 | 1.4 | 1.0 | 1.25 | 1.8 | 32.1 | 3092 |
24 | 0.4 | 1.5 | 1.4 | 1.0 | 1.25 | 1.8 | 35.2 | 3581 |
1.0 mm² :
No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Lead Sheath Thickness (mm) | Inner Sheath Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
2 | 0.4 | 1.1 | 1.1 | 0.8 | 0.9 | 1.4 | 18.4 | 1011 |
4 | 0.4 | 1.1 | 1.1 | 0.8 | 0.9 | 1.5 | 20.2 | 1204 |
6 | 0.4 | 1.2 | 1.2 | 0.9 | 0.9 | 1.6 | 23.6 | 1691 |
8 | 0.4 | 1.2 | 1.2 | 0.9 | 1.25 | 1.6 | 24.6 | 1848 |
10 | 0.4 | 1.2 | 1.3 | 0.9 | 1.25 | 1.7 | 27.5 | 2244 |
12 | 0.4 | 1.3 | 1.3 | 0.9 | 1.25 | 1.7 | 28.2 | 2383 |
16 | 0.4 | 1.3 | 1.4 | 1.0 | 1.25 | 1.7 | 30.2 | 2781 |
20 | 0.4 | 1.5 | 1.4 | 1.1 | 1.25 | 1.8 | 32.5 | 3154 |
24 | 0.4 | 1.5 | 1.5 | 1.2 | 1.6 | 1.9 | 36.5 | 3982 |
1.3 mm² :
No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Lead Sheath Thickness (mm) | Inner Sheath Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
2 | 0.4 | 1.1 | 1.1 | 0.8 | 0.9 | 1.5 | 19.8 | 1140 |
4 | 0.4 | 1.2 | 1.2 | 0.9 | 0.9 | 1.5 | 22.5 | 1588 |
6 | 0.4 | 1.2 | 1.2 | 1.0 | 1.25 | 1.6 | 25.1 | 1915 |
8 | 0.4 | 1.2 | 1.3 | 1.1 | 1.25 | 1.6 | 26.4 | 2190 |
10 | 0.4 | 1.3 | 1.3 | 1.1 | 1.25 | 1.7 | 29.7 | 2606 |
12 | 0.4 | 1.3 | 1.4 | 1.1 | 1.25 | 1.7 | 30.5 | 2843 |
16 | 0.4 | 1.3 | 1.4 | 1.2 | 1.25 | 1.8 | 32.5 | 3235 |
20 | 0.4 | 1.5 | 1.5 | 1.2 | 1.25 | 1.9 | 35.2 | 3797 |
24 | 0.4 | 1.5 | 1.5 | 1.2 | 1.6 | 1.9 | 39.5 | 4653 |
1.5 mm² :
No. of Pairs | Insulation Thickness (mm) | Bedding Thickness (mm) | Lead Sheath Thickness (mm) | Inner Sheath Thickness (mm) | Diameter of Armor Wire (mm) | Outer Sheath Thickness (mm) | Nominal O.D. (mm) | Weight* (kg/km) |
2 | 0.5 | 1.1 | 1.2 | 0.9 | 0.9 | 1.5 | 21.1 | 1303 |
4 | 0.5 | 1.2 | 1.2 | 1.0 | 0.9 | 1.5 | 23.7 | 1741 |
6 | 0.5 | 1.2 | 1.3 | 1.1 | 1.25 | 1.6 | 26.9 | 2193 |
8 | 0.5 | 1.3 | 1.3 | 1.1 | 1.25 | 1.7 | 28.7 | 2481 |
10 | 0.5 | 1.3 | 1.4 | 1.2 | 1.25 | 1.7 | 31.9 | 2995 |
12 | 0.5 | 1.3 | 1.4 | 1.2 | 1.25 | 1.7 | 32.6 | 3164 |
16 | 0.5 | 1.5 | 1.5 | 1.3 | 1.25 | 1.9 | 36.3 | 3863 |
20 | 0.5 | 1.5 | 1.6 | 1.3 | 1.6 | 1.9 | 39.2 | 4686 |
24 | 0.5 | 1.7 | 1.6 | 1.3 | 1.6 | 2.0 | 43.6 | 5471 |
*The number here is just approx. weight. It changes according to the insulation material and the conductor used in different type of extension cable and compensating cable.
Packaging & shipping
Packaging Detail: export wooden drum ,wooden iron drum and other export standard package
Delivery Detail: 10 days and also depend on the quantity
Our service
we are one of the biggest manufacture in china mainland. We will give you a perfect shopping experience . If you need visit our factory , we will meet you at the airport or train station.
Also we can offer other service
Custom Merchandise:we can make cable as your need include the color ,size and so on.we also offer OEM .
Complete Course Tracking:we can offer you the service from the business begin to you get the cable and use it .
Company information
Cable sample: we can offer the sample free .
Zhengzhou hongda cable Co., Ltd.
Established Year:1999
Registered capital of RMB:5,000,000
Factory Area:300,000m2
Main products:
Areial bundle cable ,XLPE insulated power cable ,PVC insulated power cable ,electrical wire ,bare aluminum conductor(AAC AAAC ACSR )and so on
Main export county:
USA Philippines Malaysia Indonesia Venezuela, Colombia Mexico
Dominica India South Africa Zambia Kenya and so on .
1. We have a large production base, and advanced production equipment
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Attractive design and various styles
5. Free issue:packaging list,invoice,CD installation
6. Powerful technology R&D team
7. Strict quality assurance system and perfect testing means
8. Advanced process equipment
9. Painted with powerful antiseptic Anticorrosion material paints
10. Delivery on time
11. Our roller coaster sales to Middle East,Africa,Russia,Southeast Asia, etc.
12.We have a good reputation in the overseas
Contact information
Any needs or question ,please contact us ,we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperaton.
- Next: 600V Weather Resistant PE Insulation 95mm 120mm 4 Core ABC Cable
- Previous: cable thw calibre 12, cable wire electrical 12 gauge
Contact us
Search
You May Like
- No related articles