low voltage cu/xlpe/pvc 50 sq mm 70mm 95mm 120mm copper cable

Port: | QINGDAO, SHANGHAI or SHENZHEN |
Payment Terms: | L/C,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 700 Kilometer/Kilometers per Month Depending on cu xlpe pvc copper cable specifications |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | copper cable |
Insulation Material: | XLPE |
Type: | Low Voltage |
Application: | Industrial |
Conductor Material: | Copper |
Jacket: | PVC |
Sheath Color: | Black or customized |
Insulation: | XLPE |
Conductor: | Copper conductor |
Standards: | NF C 32-322, IEC 60228 |
Voltage Rating: | 600/1000 V |
Number of Cores: | Multi Cores |
Operating Temperature Range: | -10°C to 60°C |
Short-circuit max.: | 250°C |
Max. core temperature still: | 90°C |
Product name: | low voltage cu/xlpe/pvc 50 sq mm 70mm 95mm 120mm copper cable |
Packaging Detail: | low voltage cu/xlpe/pvc 50 sq mm 70mm 95mm 120mm copper cable Packaging available on 500meters or 1000 meters per Steel & Wooden drum, other packaging can be accept. |
copper cable sample: we can offer the sample free .
low voltage cu/xlpe/pvc 50 sq mm 70mm 95mm 120mm copper cable
HR PVC:
Heat resisting PVC compound has good thermal stability at an accelerated process temperature. The rate of degradation of HRPVC compound with time under the influence of temperature is less. It has high thermal stability can withstand high continuous temperature which is an indication of performance of the cable at normal and elevated temperature in actual usage.
The cables with HR PVC compound can work continuously at an operating temperature of 85 Deg. C. The usage of HR insulated cables is recommended in humid atmosphere and at places with constant high temperature than normal temperature. The current rating of the HR insulated cables is higher than the general PVC insulated cables.
FRLS Compound:
Fire Accidents in cable galleries and other vulnerable areas like power plants and industrial complexes and in public places like theatres, hotels and airports, etc. have demonstrated the need for reliable electrical installation, resistant to fire and ability to operate during a fire without propagating it. The use of correct electrical installation makes evaluation of buildings easier, minimizes the element of panic and enables the emergency services do their job efficiently, significantly aiding damage control operations and reducing loss of life and property.
Electric Cables supplying these circuits must be manufactured and tested for certain standards and specifications concerning their behaviour in fire. Flame Retardant Low Smoke (FRLS) cables, which are manufactured using specially developed FRLS compound for sheathing, are resistant to ignition and flame propagation, and reduce smoke emission and release of acid fumes.
XLPE COMPOUND:
XLPE means cross linked polyethylene or vulcanised polyethylene. The basic material of XLPE is low density polyethylene. Polyethylene is a thermoplastic material consisting of long chain Hydrocarbon Molecules at elevated temperature and these molecules tend to move relative to one another so that the material becomes increasingly diformable and will eventually melt at a temperature of around 110 Deg. C. By means of process similar to the Vulcanisation of Rubber the PE Molecules can be cross linked. The process of cross linking or vulcanisation consists of producing chemical bonds at intervals between the long molecular chain to give a "Ladder" effect which prevents slippage between molecules. As a result of Crosslinking, the material becomes heat resistance and does not soften at higher temperature. Further it has better resistance to stress cracking and good resistance to ageing in hot air with the change in structure. There is no adverse effect on electrical properties. XLPE Cables are excellent in electrical, thermal, mechanical and chemical properties.
Type | Description | cores |
VV 0.6/1kV | 0.6/1kV copper conductor, PVC insulation, PVC sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
VLV 0.6/1kV | 0.6/1kV aluminum conductor, PVC insulation, PVC sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
VV22 0.6/1kV | 0.6/1kV copper conductor, PVC insulation, PVC inner sheath, Galvanized steel tape armored, PVC outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
VLV22 0.6/1kV | 0.6/1kV aluminum conductor, PVC insulation, PVC inner sheath, Galvanized steel tape armored, PVC outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
VV32 0.6/1kV | 0.6/1kV copper conductor, PVC insulation, PVC inner sheath, Galvanized steel wire armored, PVC outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
VLV32 0.6/1kV | 0.6/1kV aluminum conductor, PVC insulation, PVC inner sheath, Galvanized steel wire armored, PVC outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJV 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, PVC sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJLV 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, PVC sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJV22 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, PVC inner sheath, Galvanized steel tape armored, PVC outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJLV22 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, PVC inner sheath, Galvanized steel tape armored, PVC outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJV32 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, PVC inner sheath, Galvanized steel wire armored, PVC outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJLV32 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, PVC inner sheath, Galvanized steel wire armored, PVC outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJY 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, PE sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJLY 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, PE sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJY23 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, PE inner sheath, Galvanized steel tape armored, PE outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJLY23 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, PE inner sheath, Galvanized steel tape armored, PE outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJY33 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, PE inner sheath, Galvanized steel wire armored, PE outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
YJLY33 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, PE inner sheath, Galvanized steel wire armored, PE outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
WDZ-YJE 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, low smoke zero halogen flame retardant sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
WDZ-YJLE 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, low smoke zero halogen flame retardant sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
WDZ-YJE23 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, low smoke zero halogen flame retardant inner sheath, Galvanized steel tape armored, low smoke zero halogen flame retardant outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
WDZ-YJLE23 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, low smoke zero halogen flame retardant inner sheath, Galvanized steel tape armored, low smoke zero halogen flame retardant outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
WDZ-YJE33 0.6/1kV | 0.6/1kV copper conductor, XLPE insulation, low smoke zero halogen flame retardant inner sheath, Galvanized steel wire armored, low smoke zero halogen flame retardant outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
WDZ-YJLE33 0.6/1kV | 0.6/1kV aluminum conductor, XLPE insulation, low smoke zero halogen flame retardant inner sheath, Galvanized steel wire armored, low smoke zero halogen flame retardant outer sheath, low voltage power cable | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
Conductor | Inductance | Current – Carrying Capacity at 30° C * | Short circuit current at 1 sec | |||
Nom. Cross Section Area | DC Resistance at 20°C | AC Resistance at 70°C | ||||
in air | in ground | |||||
(mm²) | Max. (Ω/km) | Max. (Ω/km) | (mH/km) | Max. (A) | Max. (A) | Max. (kA) |
1.5 | 12.1 | 14.478 | 0.328 | 22 | 27 | 0.17 |
2.5 | 7.41 | 8.866 | 0.304 | 29 | 35 | 0.29 |
4 | 4.61 | 5.516 | 0.303 | 39 | 46 | 0.46 |
6 | 3.08 | 3.685 | 0.288 | 50 | 57 | 0.69 |
10 | 1.83 | 2.190 | 0.269 | 68 | 77 | 1.15 |
16 | 1.15 | 1.376 | 0.255 | 90 | 99 | 1.84 |
25 | 0.727 | 0.870 | 0.255 | 121 | 128 | 2.88 |
35 | 0.524 | 0.627 | 0.246 | 149 | 154 | 4.03 |
50 | 0.387 | 0.464 | 0.247 | 173 | 173 | 5.75 |
70 | 0.268 | 0.321 | 0.238 | 215 | 212 | 8.05 |
95 | 0.193 | 0.232 | 0.238 | 266 | 255 | 10.93 |
120 | 0.153 | 0.184 | 0.233 | 308 | 289 | 13.80 |
150 | 0.124 | 0.150 | 0.233 | 357 | 327 | 17.25 |
185 | 0.0991 | 0.121 | 0.233 | 405 | 366 | 21.28 |
240 | 0.0754 | 0.093 | 0.232 | 482 | 425 | 27.60 |
300 | 0.0601 | 0.075 | 0.231 | 552 | 479 | 34.50 |
*Further information about rating factor for certain cable arrangement can be found on supplementary technical information.
Picture of cu xlpe pvc copper cable
Packaging
Packaging available on 500 or 1000 metres
Wooden & steel drums
Shipping:
Port: Tianjin, Qingdao, Shanghai or other ports as per your requirements.
Sea freight:
FOB/C&F/CIF/DDU quotation are all available.
Q 1: I didn’t find the cu xlpe pvc frls cable I need in this page?
A: Dear Friend, we supply customized service. So, you can contact me directly for the as follows information, I will reply you asap!
Q 2: What’s your Minimum Order Quantity?
A: You are advised to please confirm with us as it is based on the specification of the cables. Normally, it is 100m for small electric wires. 500 to 1000 per drum for power cable.
Q 3: What’s your delivery time?
A: It depends on whether we just has the stock for your type. Or, it takes about 7 – 15 days for normal orders.
Q 4: How can I get a sample to check your quality?
A: After price confirmation, you can require for sample to check our quality. Sample is free, but the freight charge should be paid.
Q: What is your terms of payment ?
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shipment.
1. We have a large production base, and advanced production equipment
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Attractive design and various styles
5. Free issue:packaging list,invoice,CD installation
6. Powerful technology R&D team
7. Strict quality assurance system and perfect testing means
8. Advanced process equipment
9. Painted with powerful antiseptic Anticorrosion material paints
10. Delivery on time
11. Our roller coaster sales to Middle East,Africa,Russia,Southeast Asia, etc.
12.We have a good reputation in the overseas
Contact information
Any needs or question for cu xlpe pvc frls cable, please contact me, we will be more pleasure to service you.
Skype ID: xinyuanyy
Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725
Facebook: xin.yuan.73307
We are looking forward to your inquiry and nice cooperaton.
- Next: 0.6/1KV U 1000 ARVFV cable 4×35 4×70 4×95 4×120 4×150 (industrial armoured)
- Previous: 4c x 25mm XLPE Aluminium Cable Underground Electrical Cable Wire
Contact us
Search
You May Like
-
11kV 15kV 33kV Copper XLPE insulated 3 core electric cable Three phase copper cable prices
-
4c 25mm2 35mm2 50mm2 185mm2 Cu XLPE PVC Unarmored 600/1000V electric copper power cable
-
0.6/1kV 4x35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 CU/XLPE/PVC POWER CABLE
-
electric xlpe insulated 4c 5c 35mm2 50mm2 70mm2 95mm2 un-armoured cable