three phase and one earth core power cables 3x120 70mm2 pvc cable

Port: | Tianjin |
Payment Terms: | L/C,T/T |
Supply Ability: | 80000 Meter/Meters per Day for three phase and one earth core power cables 3x120 70mm2 pvc |
Place of Origin: | Hebei China |
Brand Name: | Hao Hua |
Model Number: | VV32 |
Insulation Material: | PVC |
Type: | Low Voltage |
Application: | Construction |
Conductor Material: | Copper |
Jacket: | PVC |
Product: | three phase and one earth core power cables 3x120 70mm2 pvc cable |
Standard: | IEC60502, BS7870, GB/T12706 |
Certificate: | CQC CCC |
Color: | Black or as per requirement |
Armour: | SWA (Remark: for single core the armour should be AWA or SSWA) |
Number of cores: | 3 core |
Range of Nominal cross section: | 1.5 mm2 ~ 630 mm2 |
Samples: | free |
Delivery Detail: | Within 7~15 working days |
Packaging Detail: | Steel /wooden drum for three phase and one earth core power cables 3x120 70mm2 pvc cable or as per your requirement |
three phase and one earth core power cables 3×120 70mm2 pvc cable
Advantages:
–Factory Direct Supply of low voltage, medium voltage and high voltage power cable with armor or without armor,
–Armouring Type: Unarmoured, STA Steel Tape Armored, SWA Steel Wire Armored Power Cable
–OEM Service Provided,
–Best Cable Quality, Premium Service,
–All for Customers!
1. Application for three phase and one earth core power cables 3×120 70mm2 pvc cable
It is used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines.
2. Performance Characteristics for three phase and one earth core power cables 3×120 70mm2 pvc cable
1).The long-time working temperature of conductor of PVC insulated control cable is 70°C.
The long-time working temperature of conductor of XLPE insulated control cable is 90°C.
2).During short circuit(max permanent time is not more than 5 seconds),the max temperature of cable conductor is not more than 160C.
3).Ambient temperature is not lower than 0 °C.
4).it's minium bending when cable is installed.
Unarmored 6D(D=overall diameter)
Armored or copper-tape screened 12D(D=overall diameter)
Shielded flexile cable 6D(D=overall diameter)
3. Types and descriptions for three phase and one earth core power cables 3×120 70mm2 pvc cable
Armored Cable Type |
Low Voltage and Medium Voltage Armored Power Cable Specification |
|
Copper Core | Aluminium Core | |
VV22 | VLV22 | Copper Conductor Galvanized Steel Tape Armored Power Cable With PVC Insulation and PVC Sheath |
VV23 | VLV23 | Copper Conductor Galvanized Steel Tape Armored Power Cable With PVC Insulation and PE Sheath |
VV32 | VLV32 | Copper Conductor Fine Steel Wire Armored Power Cable With PVC Insulation and PVC Sheath |
VV33 | VLV33 | Copper Conductor Fine Steel Wire Armored Power Cable With PVC Insulation and PE Sheath |
VV42 | VLV42 | Copper Conductor Thick Steel Wire Armored Power Cable With PVC Insulation and PVC Sheath |
VV43 | VLV43 | Copper Conductor Thick Steel Wire Armored Power Cable With PVC Insulation and PE Sheath |
YJV22 | YJLV22 | Copper Conductor Galvanized Steel Tape Armored Power Cable With XLPE Insulation and PVC Sheath |
YJV23 | YJLV23 | Copper Conductor Galvanized Steel Tape Armored Power Cable With XLPE Insulation and PE Sheath |
YJV32 | YJLV32 | Copper Conductor Fine Steel Wire Armored Power Cable With XLPE Insulation and PVC Sheath |
YJV33 | YJLV33 | Copper Condcutor Fine Steel Wire Armored Power Cable With XLPE Insulation and PE Sheath |
YJV42 | YJLV42 | Copper Conductor Thick Steel Wire Armored Power Cable With XLPE Insulation and PVC Sheath |
YJV43 | YJLV43 | Copper Condcutor Thick Steel Wire Armored Power Cable With XLPE Insulation and PE Sheath |
4.Main Features for three phase and one earth core power cables 3×120 70mm2 pvc cable
Operating temperature
Max. Permissible continuous operating temperature of Conductors shall not exceed 70℃
Conductor Short circuit temperature
Not exceeding 160℃ .( Max. duration 5 seconds)
Bending radius:
Bending radius of single core cable: 20D
Bending radius multi-core cable: 15D
D=Actual overall diameter of cable (mm)
Installation temperature:
The lowest temperature of installation is 0℃ .
Laying conditions and basic parameters for calculating current ratings:
Method of laying Ambient temperature
In air 40℃
Direct burial 25℃
Soil thermal resistivity 1.0℃·m/W
Layout of single core cables: In triangle (Touch each other)
Types of Power Cable that We Also Manufacuture– For Your Reference:
About us
Hongliang Cable Co., Ltd.
Established Year: 1988
Registered capital of RMB: 201,800,000
Total assets : 28.7millions
Factory Area: 45425 mm2
Manufacturing Capacity per year: 250000km
Number of Employees: 460
1. Which payment terms do you accept?
a) 30% DEPOSIT IN ADVINCE,BANLANCE AGAINST THE COPY OF B/L.
b) 100% L/C at sight.
2. What is your MOQ?
You are advised to please confirm it with us directly as it’s based on different cables.
Usually it’s 100 meters for Medium Voltage Cables.
3. What about your delivery time?
According to the order’s quantity . Usually is 15 – 30 working days.
4.How to packing the goods ?
Usually in wooden drum or steel wooden drums .The cable wire is usually coiled.
5.How to buy power cable if the type is unknown
Please tell me the application, we will help you find the type most appropriate.
6.The warranty
Oversea technical service center 24 hous available
Many thanks for your reading , if any questions please feel free to contact me.