3x300mm2 Medium Voltage XLPE Cable XLPE DSTA PVC YJV22

3x300mm2 Medium Voltage XLPE Cable XLPE DSTA PVC YJV22
Place of Origin: Shanghai China
Brand Name: SAHN, OEM
Model Number: YJVR, YJVRP, YJV, YJV22, YJV32, YJV72,ZR-YJV
Insulation Material: XLPE
Type: rated voltage below 35kV
Application: Power Station
Conductor Material: Copper
Jacket: PVC
Cable type: xlpe dsta pvc YJV22 cable 4x300 LV
Conductor: Pure Copper
Insulation: XLPE
Rated voltage: 0.6/1kV ~ 26/35kV
Cores: 1, 2, 3, 4, 5
Armour: SWA STA AWA DBT
Sheath: PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Special requiremets: LSZH, Fire-resistant
Certificates: ISO9001, IEC60502, KEMA
Warranty: 2 years
Selling Units: Single item
Single package size: 20X20X14 cm
Single gross weight: 60 KG
Package Type: wooden drums according to quantity and container or required
Package Preview: https://sc01.alicdn.com/kf/Hdd75f7fc2f274e7d8030c21ce4b9295eG.jpg_640x640.jpg

3x300mm2 Medium Voltage XLPE Cable XLPE DSTA PVC YJV22 Cable 4×300 sqmm 0.6/1kV

26/35kV 3x300mm2 Medium Voltage XLPE Cable

Structure

 

1 ….. stranded bare copper
2 ….. inner layer of semi-conducting material
3 ….. core insulation of cross-linked polyethylene
4 ….. outer layer of semi-conducting material
5 ….. semi-conducting tape
6 ….. screen of copper wires

7 ….. Fillers strip, Yarn, or Paper
8 ….. Non woven Wrapping tape or Flame Retardant

9 ….. Extruded PVC Inner Covering

10 …. Galvanized Steel Tape Armoured
11 …. Overall Sheath: polyvinylchloride (PVC) or FR-PVC, PE, LSOH

 

                        

Application

                          
Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.

Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability.

Used in transformer stations, switching blocks, in electric power plants and industrial plants.

To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

 

 

Standard

 

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

 

 

Specification

 

MV(6 to 35kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV No.of Core Conductor cross-section area(mm2)
xlpe insulation 1 core 3 core 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu core Al Core
YJV, N2XSY;PVC sheathed power cable YJLV, NA2XSY; PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable YJLV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable

 

0.6/1kV XLPE DSTA PVC YJV22 Cable 4×300 sqmm

Applications

This product is applicable to the fixed routing in the power distribution network or the industrial equipment with power frequency rated voltage of 1kV and below.
For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces.

Application Standards

 

IEC/BS/UL/GB Standards

 

Manufacture Standards

International: IEC 60502, IEC 60228, (IEC 60332-3 for FR-type only)
China: GB/T 12706, (GB/T 18380-3 for FR-type only)
Other standards such as BS,DIN and ICEA upon request

 

 

Constructions

Code : VV62, VV72, YJV62, YJV72, VLV62, VLV72, YJLV62, YJLV72
Standarts : TS IEC 60502, IEC 502, VDE 0271, BS 6346
Construction : 1- Solid, Stranded or Flexible Copper / ALuminum Conductor
    2- XLPE insulation (cross-linked PE) or PVC
    3- Sluminum Wire Armour or Stainless Steel Tape Armour
    4- PVC outer sheath, or PE, LSOH
Application : Preferably for installation indoors, in cable ducts and in industrial plants or
    switching stations, underground installation with additional protection where
    mechanical damage is unexpected.
Technical Data : Max. operating temperature 90 ºC
    Short circuit temperature 250 ºC

 
Code Designation

 

YJ: XLPE insulation

V: PVC insulation or sheath

72: Aluminum wire armoring

62: Stainless steel tape armour
 

Technical data

 

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables

 

Ordering

 

Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

 

 

Certification

Factory show

FACTORY SHOW

 

PRO.&INS. Process

PRO.&INS. PROCESS

 

Note:
1. The process of production and inspection applies to Electric Power Cable, Control Cable, Aerial Cable, House Wiring Cable and so on. The process is not all same for different types of products.
2. The process with the mark is for medium voltage power cable.

PACKING AND SHIPPING

 
Packing and shipping

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

After-service

 

 

Quote Request Information

 

1. Material of conductor/insulation/sheath.

2. Voltage classes.

3. Cross section, Short circuit current capacity, tension strength.

4. Order Quantity

 

 

Our Services

 

♦ We are the one of biggest manufacture of electric wire and power cable in China and has more than 20 years producing and marketing experience.

♦ We accept OEM. The cable size and material are customized.Ur own logo and

own design are welcome. We will produce according to your requirement and description;

♦ Please send us inquiry for more products info and we will give you feedback in 12 hours.

FAQ

 

1. Shipping: By sea or air due to heavy weight. Samples will be send by DHL, Fedex. etc

2. Payment: We accept T/T, L/C , just choose what you like

3. Delivery time: Generally 7~10 working days upon receipt deposit. According to the quantity.

4. MOQ: Generally our MOQ is 1000meters. samples below 20 centimeter can be provided freely.

 

 

You can contact me directly for soonest response 🙂

 

 

 

 

 

 