ACCC Conductor – Aluminum Conductor Carbon Fiber Composite Core Reinforced Conductor – Carbon Cored Wire
ACCC/TW
(Aluminium Conductor Composite Core / Trapezoidal Wires)
Standard Specification : ASTM B 857 : 2011, ASTM B 609 : 2012, Manufacturer Specification OR EQUVALANT IEC SPECIFICATION
1.Applications
Considering the cost of inputs from the view of energy, although ACCC has higher investment cost at the beginning, it can save energy for at least 25% (here only take the DC resistance into consideration), if considering the steel core hysteresis loss effect and corona phenomenon, the application of ACCC conductors can save energy for more than 30%; In addition, ACCC conductors can guarantee the long term running at 160 ℃ (when the operating temperature is higher than 70 ℃ until 160℃, the sag of the ACCC wire line has almost no change that can fully guarantee the safe distance to the ground when working in high temperature, thus it can be used as high temperature wire), Moreover, it retains twice transport currency after the completion of the line that don’t need to consider to transform the line when the transport capacity increases in the future.
2.Standards
GB/T 17048-1997, IEC 60889:1987
ASTM B 857 : 2011, ASTM B 609 : 2012
Other standards such as BS,DIN and ICEA upon request
MECHANICAL PROPERTIES ( ACCC )
Type Code Name |
Stranding |
Nominal Diameter (mm) |
Cross Sectional Area (mm²) |
Nominal Weight (kg/km) |
Rated Strength (kN) min. |
|||||
No. of Al Layers |
No. of Al Wires |
Total |
Core |
Total |
Al |
Total |
Al |
Core |
||
Helsinki 160 2 16 15.65 5.97 180.9 152.9 480 426 54 64.0 |
||||||||||
Copenhagen 220 2 16 18.29 5.97 251.0 223.0 670 616 54 65.6 |
||||||||||
Reykjavik 225 2 20 18.82 7.11 266.2 226.5 702 626 76 91.1 |
||||||||||
Glasgow 230 2 16 19.53 7.75 283.8 236.7 742 655 87 107.4 |
||||||||||
Lisbon 310 2 16 21.78 7.11 358.4 318.7 957 881 76 93.2 |
||||||||||
Amsterdam 360 2 20 23.55 7.75 418.5 371.3 1,113 1,026 87 110.6 |
||||||||||
Brussels 415 2 20 25.14 8.13 477.2 425.3 1,275 1,177 98 122.1 |
||||||||||
Stockholm 460 2 20 26.40 8.76 527.5 467.2 1,406 1,293 113 141.1 |
||||||||||
Warsaw 510 2 22 27.72 8.76 574.9 514.6 1,539 1,426 113 142.3 |
||||||||||
Dublin 520 2 22 28.15 9.53 594.8 523.5 1,559 1,427 132 166.4 |
||||||||||
Mahakam 540 3 36 29.00 10.54 631.9 544.6 1,675 1,509 166 257.0 |
||||||||||
Hamburg 550 2 22 28.62 8.76 613.8 553.5 1,646 1,533 113 143.2 |
||||||||||
Vienna 620 3 36 30.42 8.76 689.3 629.1 1,854 1,741 113 145.0 |
||||||||||
Prague 690 3 36 31.77 8.76 758.0 697.7 2,032 1,919 113 146.5 |
ELECTRICAL PROPERTIES ( ACCC )
Type Code Name |
Max DC Resistance at 20°C ( ohm/km) |
Current Carrying Capacity * (A) |
Inductive Reactance at 50 Hz for 1 feet radius ( ohm /km) |
Capacitive Reactance at 50 Hzfor 1 feet radius (Mohm.km) |
Helsinki 160 0.1861 792 0.246 0.210 |
||||
Copenhagen 220 0.1279 1,008 0.236 0.201 |
||||
Reykjavik 225 0.1280 1,018 0.234 0.199 |
||||
Glasgow 230 0.1192 1,068 0.232 0.197 |
||||
Lisbon 310 0.0888 1,285 0.225 0.191 |
||||
Amsterdam 360 0.0761 1,426 0.220 0.186 |
||||
Brussels 415 0.0673 1,552 0.216 0.183 |
||||
Stockholm 460 0.0612 1,655 0.213 0.180 |
||||
Warsaw 510 0.0556 1,766 0.210 0.177 |
||||
Dublin 520 0.0541 1,800 0.209 0.176 |
||||
Mahakam 540 0.0526 1,845 0.208 0.174 |
||||
Hamburg 550 0.0513 1,858 0.208 0.175 |
||||
Vienna 620 0.0455 2,015 0.204 0.172 |
||||
Prague 690 0.0412 2,148 0.202 0.169 |