BS5308 Part 2 Type pair insrumentation PVC-IS-OS-SWA-PVC/ RE-Y(St)Y PIMF SWAY Cable

Port: | qingdao |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 1000 Kilometer/Kilometers per Week good quality on Instrument Cable |
Place of Origin: | Henan China |
Brand Name: | hongda |
Model Number: | instrumentation cable |
Shielding: | Foil |
Conductor Material: | Copper |
Jacket: | PVC |
Insulation Material: | PVC |
Model: | Instrumentation Cable |
Type: | armored xlpe cable |
model2: | insulated Instrument Cable |
standard: | bs5308 IEC 602270 |
Insulation: | pvc/pe/xlpe |
Jacket/sheath: | pvc/pe/xlpe |
Voltage: | 300/500 |
Quality control: | ISO9001 |
Sample: | available |
Delivery Detail: | 20 days |
Packaging Detail: | wooden/metal wooden drums or according to your require |
BS5308 Part 2 Type pair insrumentation PVC-IS-OS-SWA-PVC/ RE-Y(St)Y PIMF SWAY Cable
Application
Cables
The armoured versions (Part 2 Type 2) are generally used when the risk of mechanical damage is increased. The galvanised steel wire armour provides excellent protection. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services, Also used for the interconnection of electrical equipment and instruments, typically in chemical or petrolchemical industry. The armored versions are generally use for outdoor installation for direct burial or installed in the duct and suitable for wet and damp areas.
Construction
Conductor
Annealed or tinned copper, sizes: 0.5mm2 and 0.75mm2 mulitistranded(Class 5), 1.5mm2 multistranded(Class 2) to BS6360
Insulation
PVC (polyvinyl chloride),type TI1 to BS 6746
Pairing
Two insulated conductors uniformly twisted together with a lay not exceeding 100mm
Colour code
Multipair cables:See technical information
Individual screen
Aluminium/polyester tape is applied over each pair metallic side down in contact with tinned copper drain wire, 0.5mm2
Binder tape
PETP transparent tape
Collective screen
Inner Sheath
Amour
Outer sheath
Sheath colour
Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm2
PVC (polyvinyl chloride), type TM 1 to BS 6746
Galvanized steel wire armour
PVC Sheath, type TM 1 or type 6 to BS 6746
Black or blue
PETP transparent binder tape PE inner sheath Tinned copper drain wire Galvanized steel wire armour
Annealed or tinned copper, sizes: 0.5mm2 and 0.75mm2 mulitistranded(Class 5), 0.5 mm2, 1.0 mm2 solid(Class 1), 1.5mm2 or 2.5mm2, multistranded(Class 2) to BS6360 PE (Polyethylene) type 03 to BS6234 Two insulated conductors uniformly twisted together with a lay not exceeding 100mm
See technical information
PETP transparent tape Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm2 PE (Polyethylene) type 2C or type 03 to BS6234 Galvanized steel wire armour PVC Sheath, type TM 1 to BS 6746
Black or blue
Standard of insulated cable:
It is manufacture under GB/T12706-2002 standard(The same as IEC60502).
UP TO 600/1000V PE INSULATION INSTRUMENTATION CABLE
Generally to IEC Standard No.: BS 5308-1978
Maximum working temperature 70° C
PE or PVC/Multi-pair/ Collectively screened/Unarmoured/PVC
PE or PVC/Multi-pair/ Individually & Collectively screened/Unarmoured/PVC
PE or PVC/Multi-pair/ Collectively screened/Galvanized steel wire armoured/PVC
PE or PVC/Multi-pair/ Individually & Collectively screened/ Galvanized steel wire armoured/PVC
PE or PVC/Multi-pair/ Collectively screened/Galvanized steel wire braiding/PVC
PE or PVC/Multi-pair/ Individually & Collectively screened/ Galvanized steel wire braiding/PVC
Voltage rating
600/1000V
Temperature rating
-20°C to +60°C
Bending radius
Single core: 10 x overall diameter
Multicores: 8 x overall diameter
Instrument Cable Application:
For use in installations designed to connect electrical instrumentation circuits and provide communication services in and around process plants. Suitable for direct burial applications.
Specification of instrument cable:
Instrument Cable Conductors:
0.5mm – class 5 flexible copper
0.75mm – class 5 flexible copper
1.5mm – class 2 stranded copper
Insulation: PE (Polyethylene)
Screen: CAM (Collective Aluminium Mylar)
Bedding: PE (Polyethylene)
Armour: SWA
Outer Sheath: PVC (Polyvinyl-Chloride)
Voltage Rating: 300/500volts
Temp. Rating: 65 C
Flexible instrumentation multi-core cables about PVC insulated and twisted parallel cable
Standard: National Standard GB/T 5023; IEC60227
Rated Voltage: 300/300V;
Construction: 1. annealed flexible copper conductor
2.PVC insulated
Application: used for electric appliance, electric tool, electric instruments and lighting, automatic system
Application of insulated cable Instrument Cable :
It is used to transmit and distribute power on the power line of A. C. Rated voltage 0.6/1kV.
XLPE insulated electric cable Instrument Cable 0.6/1kv | |||||||||||
norminalsectional area | insulati-on thicknes | sheath thickness(mm) | overal diameter of cable (mm) | D.C resistance of conductor(km) | current rating | ||||||
in air(A) | direct in soil(A) | ||||||||||
cu | Al | cu | Al | cu | Al | ||||||
1×1.5 | 0.7 | 1.5 | 6 | <=12.1 | <=12.1 | 30 | 25 | 45 | 35 | ||
1×4 | 0.7 | 1.5 | 7 | <=7.41 | <=7.41 | 45 | 35 | 60 | 50 | ||
1×6 | 0.7 | 1.5 | 7 | <=3.08 | <=4.61 | 55 | 45 | 70 | 55 | ||
1×35 | 0.9 | 1.5 | 12 | <=0.524 | <=0.868 | 175 | 140 | 190 | 150 | ||
1×50 | 1 | 1.5 | 13 | <=0.387 | <=0.641 | 210 | 170 | 225 | 180 | ||
1×70 |
1 .1 |
1.5 | 14 | <=0.268 | <=0.443 | 270 | 215 | 280 | 225 | ||
1×95 | 1.1 | 1.5 | 16 | <=0.193 | <=0.320 | 340 | 275 | 335 | 270 | ||
1×120 | 1.2 | 1.5 | 18 | <=0.153 | <=0.253 | 400 | 320 | 380 | 305 | ||
1×150 | 1.4 | 2 | 21 | <=0.124 | <=0.206 | 460 | 370 | 425 | 340 | ||
1×185 | 1.6 | 2 | 23 | <=0.0991 | <=0.164 | 530 | 415 | 480 | 375 | ||
1×240 | 1.7 | 2 | 25 | <=0.0754 | <=0.125 | 625 | 490 | 555 | 435 | ||
… | |||||||||||
3×1.5 | 0.7 | 1.5 | 10 | <=12.1 | <=12.1 | 25 | 25 | 30 | 30 | ||
3×2.5 | 0.7 | 1.5 | 11 | <=7.41 | <=12.1 | 30 | 25 | 35 | 30 | ||
3×4 | 0.7 | 1.5 | 12 | <=4.61 | <=7.41 | 40 | 30 | 50 | 40 | ||
… | |||||||||||
Attention: We can provide more info than above data, if needed.The above are just some examples. |
Using features of insulated cable Instrument Cable :
1. Rated voltage: Uo/U: 0.6/1kV
2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 160oC.
4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
Model: insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable
welcome to inquire us Instrument Cable
- Next: 4x2x0.75mm2 armored instrument cable cu instrumentation cable
- Previous: BS5308 600v copper insrumentation cable with drain wire Part 1 Type 2 PE-OS screen -SWA-PVC RE-2Y(St)YSWAY
Contact us
Search
You May Like
-
300/500V BS5308 1 pair 1.5mm2 PE/XLPE insulated Galvanized SWA armour instrumentation cable
-
cu conductor xlpe/pe/pvc insulation instrumentation cable 300/500V RE-2Y(ST)Y PIMF-SWA
-
PVC/PE insulated in1.5mm2 individual or overall screened instrumentation cable
-
1 Pair 12 twisted Pairs 1.5mm2 Cu/PVC/OSCR/PVC instrumentation cable
-
Multi pairs 4 pairs 20 pairs TIN Cu/PVC/ISCR/OSCR instrumentation cable 1.5mm