70mm2 120mm 240mm2 4 core armoured power cable

70mm2 120mm 240mm2 4 core armoured power cable
Port: Shanghai
Payment Terms: L/C,T/T
Supply Ability: 100000 Meter/Meters per Month
Place of Origin: Shanghai China
Brand Name: SAHN, OEM
Model Number: N2XSY, YJV, YJV22, YJV32, YJV72,ZR-YJV
Insulation Material: XLPE
Type: Medium Voltage
Application: Power Station
Conductor Material: Copper
Jacket: PVC
Standard: IEC60502
Certificates: CE, RoHS, CCC, KEMA
Special requiremets: Armour, LSZH, Fire-resistant
Warranty: 2 years since delivery
Packaging Detail: wooden drums according to quantity and container or required

70mm2 120mm 240mm2 4 core armoured power cable

  

Constructions

 

Conductor

Compact Stranded Copper Conductor, Class 2 as per IEC 60228

Circular solid Copper Conductor, Class 1 as per IEC 60228

Flexible Stranded Copper Conductor, Class 5 as per IEC 60228

Conductor Screen

Semi-conductor (MV only)

Insulation

XLPE(Cross-linked polyethylene)

Insulation Screen

Semi-conductor (MV only)

Separate Screen

Copper Tape or Copper Wire+Copper Tape(MV must, LV optional)

Filler

PP Yarn, or Paper

Wrapping Tape

PP

Inner Covering

Extruded PVC (MV only)

Armour

Steel Wire, or Steel Tape, or Aluminium Tape optional

Overall Sheath

PVC or PE

 

Applications

 

Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.

 

Standards

 

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

 

Technical data

 

Rated voltage: 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

                                15 x cable O.D for single-core armoured cables

                                15 x cable O.D for multi-core non-armoured cables

                                12 x cable O.D for multi-core armoured cables

 

Certificates

 

CE, RoHS, CCC, KEMA and more others at request 

 

Product Line

 

Company presentation

 

Tags: , ,

Contact us

 

 

 

Search