6.35/11kV & 12.7/22kV Non Screened ABC -Aerial Bundled Cables to BS 7870-5 with AL conductor XLPE Insulated

6.35/11kV & 12.7/22kV Non Screened ABC -Aerial Bundled Cables to BS 7870-5 with AL conductor XLPE Insulated
Port: Qingdao port for aerial cable
Payment Terms: L/C,T/T,Western Union,MoneyGram
Supply Ability: 2200 Kilometer/Kilometers per Month aerial cable
Place of Origin: Henan China
Brand Name: Hongda bare conductor
Model Number: ABC Cable
Insulation Material: no insulation
Type: Low Voltage
Application: Overhead
Conductor Material: Aluminum
Jacket: no sheath
Material: aloy aluminum
Mark: CCC, IEC
Standard: AWG, IEC, BS, ASTM
Using: Overhead, power transmission lines
Packaging Detail: standard export wooden drums each end of cable shall be firmly and properly secured to drum for aerial cable
6.35/11kV & 12.7/22kV Non Screened ABC -Aerial Bundled Cables to BS 7870-5 with AL conductor XLPE Insulated

ABC – Aerial Bundled Cables APPLICATION

Medium voltage Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders
to residential premises.

 

ABC – Aerial Bundled Cables STANDARDS

Basic design to IEC 60502 / AS/NZS 3599-1 standards

 

ABC – Aerial Bundled Cables CONSTRUCTION

Phase Conductor: Circular compacted stranded H68 aluminium to BS2627.
Conductor Screen: Extruded semi-conductive layer.
insulation: XLPE.
insulation Screen: Extruded semi-conductive layer.
metallic Screen(optional): Copper wire screen or copper tape screen.
Separator: Semi-conductive swellable tape.
outer Sheath: HDPE.
Support Conductor: Galvanized steel wires.
Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel
wires in a right hand lay.

Construction Parameters

IEC 60502 6.35/11 kV ABC for Overhead Distribution Lines

Number of Cores
xNominal
Cross Section

Phase Conductor

Messenger Suspension Unit

Continuous
current
rating
at
300C
ambient
temp

Stranding Nominal Sectional Area Maximum
Conductor
Resistance
Stranding Nominal Sectional Area Breaking
Load
No.×mm² No.×mm mm² Ω/Km No.×mm mm² KN  A
3X50 + 1X25 19/1.78 50 0.641 7/3.0 50 60 116
3X70 + 1X50 19/.14 70 0.443 7/3.15 50 62 210
3X95+ 1X50 19/2.52 95 0.32 7/3.0 50 60 173
3X185+1X120 37/2.52 185 0.164 7/4.67 120 150 259
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 365
3X240 +1X50 61/2.25 240 0.125 7/3.15 50 62 500

Other cross-sections can be offered upon request.

 

IEC 60502 19/33 kV ABC for Overhead Distribution Lines

Number of Cores
xNominal
Cross Section

Phase Conductor

Messenger Suspension Unit

Continuous
current
rating
at
300C
ambient
temp

Stranding Nominal Sectional Area Maximum
Conductor
Resistance
Stranding Nominal Sectional Area Breaking
Load
No.×mm² No.×mm mm² Ω/Km No.×mm mm² KN  A
3X50 + 1X50 19/1.78 50 0.641 7/3.0 50 60 165
3X150+ 1X50 37/2.25 150 0.206 7/3.0 50 60 315
3X185+1X70 37/2.52 185 0.164 7/3.57 70 91 355
3X70 +1X50 19/2.14 7 0.443 7/3.15 50 62 250
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 370

Other cross-sections can be offered upon request.

 

AS/NZS 3599 Part 1 6.35/11 kV AL/XLPE /HDPE Non-screened Cables

Number of Cores
xNominal
Cross Section

Phase Conductor

Messenger Suspension Unit

Nominal Sectional Area

Breaking
Load

Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation Screen
Thickness
of
Sheath
Stranding
No.×mm² mm mm mm mm No.×mm mm² KN
3×35 6.9 3.4 0.8 1.2 7/4.75 52.4 1370
3×50 8.1 3.4 0.8 1.2 7/4.75 54.6 1530
3×70 9.7 3.4 0.8 1.2 7/4.75 57.8 1790
3×95 11.4 3.4 0.8 1.2 7/4.75 61.3 2100
3×120 12.8 3.4 0.8 1.2 19/3.50 67.3 2540
3×150 14.2 3.4 0.8 1.2 19/3.50 70.1 2840
3×185 15.7 3.4 0.8 1.2 19/3.50 73.1 3190

Other cross-sections can be offered upon request.

 

AS/NZS 3599 Part 1 6.35/11 kV AL/XLPE /CWS/HDPE Screened Cables

Number of Cores
xNominal
Cross Section
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation Screen
Copper Wire Screen Stranding Thickness
of
Sheath
Galvanized Steel Wire Stranding Nominal Sectional Area Breaking
Load
No.×mm² mm mm mm No.×mm mm No.×mm mm² KN

Light Duty Screen

3×35 6.9 3.4 0.8 25/0.85 1.8 7/2.00 54.1 1820
3×35 6.9 3.4 0.8 25/0.85 1.8 19/2.00 58.1 2130
3×50 8.1 3.4 0.8 25/0.85 1.8 19/2.00 60.4 2300
3×70 9.7 3.4 0.8 25/0.85 1.8 19/2.00 63.6 2570
3×95 11.4 3.4 0.8 25/0.85 1.8 19/2.00 67.0 2900
3×120 12.8 3.4 0.8 25/0.85 1.8 19/2.00 69.8 3190
3×150 14.2 3.4 0.8 25/0.85 1.9 19/2.00 73.0 3530
3×185 15.7 3.4 0.8 25/0.85 1.9 19/2.00 76.0 3890

Heavy Duty Screen

3×35 6.9 3.4 0.8 40/0.85 1.8 7/2.00 54.1 2050
3×35 6.9 3.4 0.8 40/0.85 1.8 19/2.00 58.1 2360
3×50 8.1 3.4 0.8 23/1.35 1.8 19/2.00 62.4 2820
3×70 9.7 3.4 0.8 32/1.35 1.8 19/2.00 65.6 3440
3×95 11.4 3.4 0.8 39/1.35 1.8 19/2.00 69.0 4030
3×120 12.8 3.4 0.8 39/1.35 1.8 19/2.00 71.8 4320
3×150 14.2 3.4 0.8 39/1.35 1.9 19/2.00 75.0 4670
3×185 15.7 3.4 0.8 39/1.35 1.9 19/2.00 78.0 5020

Other cross-sections can be offered upon request.

 

AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /HDPE Non-screened Cables

Number of Cores
xNominal
Cross Section

Phase Conductor

Messenger Suspension Unit

Nominal Sectional Area

Breaking
Load

Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation Screen
Thickness
of
Sheath
Stranding
No.×mm² mm mm mm mm No.×mm mm² KN
3×35 6.9 5.5 0.8 1.2 7/4.75 61.0 1780
3×50 8.1 5.5 0.8 1.2 7/4.75 63.3 1970
3×70 9.7 5.5 0.8 1.2 7/4.75 66.5 2260
3×95 11.4 5.5 0.8 1.2 7/4.75 69.9 2600
3×120 12.8 5.5 0.8 1.2 19/3.50 75.9 3070
3×150 14.2 5.5 0.8 1.2 19/3.50 78.7 3390
3×185 15.7 5.5 0.8 1.2 19/3.50 81.7 3760

Other cross-sections can be offered upon request.

 

AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /CWS/HDPE Screened Cables

Number of Cores
xNominal
Cross Section
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation Screen
Copper Wire Screen Stranding Thickness
of
Sheath
Galvanized Steel Wire Stranding Nominal Sectional Area Breaking
Load
No.×mm² mm mm mm No.×mm mm No.×mm mm² KN

Light Duty Screen

3×35 6.9 5.5 0.8 25/0.85 1.8 7/2.00 62.7 2280
3×35 6.9 5.5 0.8 25/0.85 1.8 19/2.00 66.7 2580
3×50 8.1 5.5 0.8 25/0.85 1.8 19/2.00 69.0 2780
3×70 9.7 5.5 0.8 25/0.85 1.9 19/2.00 72.6 3110
3×95 11.4 5.5 0.8 25/0.85 1.9 19/2.00 76.0 3460
3×120 12.8 5.5 0.8 25/0.85 2.0 19/2.00 79.2 3810
3×150 14.2 5.5 1.0 25/0.85 2.0 19/2.00 82.8 4230
3×185 15.7 5.5 1.0 25/0.85 2.1 19/2.00 86.2 4650

Heavy Duty Screen

3×35 6.9 5.5 0.8 40/0.85 1.8 7/2.00 62.7 2510
3×35 6.9 5.5 0.8 40/0.85 1.8 19/2.00 66.7 2810
3×50 8.1 5.5 0.8 23/1.35 1.8 19/2.00 71.0 3300
3×70 9.7 5.5 0.8 32/1.35 1.9 19/2.00 74.6 3970
3×95 11.4 5.5 0.8 39/1.35 1.9 19/2.00 78.0 4600
3×120 12.8 5.5 0.8 39/1.35 2.0 19/2.00 81.2 4950
3×150 14.2 5.5 1.0 39/1.35 2.0 19/2.00 84.8 5360
3×185 15.7 5.5 1.0 39/1.35 2.1 19/2.00 88.2 5790

Other cross-sections can be offered upon request.

 

Technical Data

Nominal
Cross Section

Continuous Current Rating

Still air 1m/s wind 2m/s wind
mm² A A A
35 105 145 165
50 125 170 200
70 150 215 250
95 180 260 300
120 205 300 350
150 230 340 395
185 265 390 450

 

Quadruplex Service Drop -Aluminum Conductor

Applications

Used as overhead cable to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

 

Triplex service drop -Aluminum Conductor

Applications

Used as overhead cable to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

 

Duplex Service Drop -Aluminum Conductor

Applications
Primarily used as overhead cable or air cable for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

 

 

 

 

Contact information

 

If you can't find the product you need in the list, please contact me, and I will serve for you wholeheartedly !!!

We are looking forward to your inquiry and nice cooperaton.

 