ABC Cable Structure
|
Construction &Cross sectional area |
Insulated Conductors | Suspension neutral | Cable | |||||||||
| Distribution Phase | Street lightning | |||||||||||
| Number &Cross section area | No.of Wires | Approx conductor Diameter | Max. Resistance at 20℃ | Current Carrying Capacity | Number &Cross section area | Current Carrying Capacity | Approx Suspension Wire Diameter | Breaking load | Max. Resistance at 20℃ | Approx. Cable Diameter | Approx. Cable Weight | |
| mm2 | mm2 | mm | ohm/km | A | mm2 | A | mm | kN | ohm/km | mm | kg/km | |
| 2×16 | 2×16 | 7 | 4.8 | 1.91 | 93 | – | – | – | – | – | 15 | 132 |
| 2×25 | 2×25 | 7 | 6.0 | 1.200 | 122 | – | – | – | – | – | 18.5 | 200 |
| 2×35 | 2×35 | 7 | 7.0 | 0.868 | 129 | – | – | – | – | – | 22 | 280 |
| 2×50 | 2×50 | 7 | 8.4 | 0.641 | 158 | – | – | – | – | – | 24 | 370 |
| 4×16 | 4×16 | 7 | 4.8 | 1.910 | 83 | – | – | – | – | – | 18 | 265 |
| 4×25 | 4×25 | 7 | 6.0 | 1.200 | 111 | – | – | – | – | – | 22 | 400 |
| 4×35 | 4×35 | 7 | 7.0 | 0.868 | 131 | – | – | – | – | – | 26 | 550 |
| 3×25+54.6 | 3×25 | 7 | 6.0 | 1.200 | 112 | – | – | 9.6 | 16 | 0.63 | 30 | 470 |
| 3×25+54.6+1×16 | 3×25 | 7 | 6.0 | 1.200 | 112 | 1×16 | 60 | 9.6 | 16 | 0.63 | 30 | 570 |
| 3×25+54.6+2×16 | 3×25 | 7 | 6.0 | 1.200 | 112 | 2×16 | – | 9.6 | 16 | 0.63 | 30 | 640 |
| 3×35+54.6 | 3×35 | 7 | 7.0 | 0.868 | 138 | – | – | 9.6 | 16 | 0.63 | 33 | 580 |
| 3×35+54.6+1×16 | 3×35 | 7 | 7.0 | 0.868 | 138 | 1×16 | 60 | 9.6 | 16 | 0.63 | 33 | 690 |
| 3×35+54.6+2×16 | 3×35 | 7 | 7.0 | 0.868 | 138 | 2×16 | – | 9.6 | 16 | 0.63 | 33 | 750 |
| 3×50+54.6 | 3×50 | 7 | 8.4 | 0.641 | 168 | – | – | 9.6 | 16 | 0.63 | 36 | 720 |
| 3×50+54.6+1×16 | 3×50 | 7 | 8.4 | 0.641 | 168 | 1×16 | 60 | 9.6 | 16 | 0.63 | 36 | 820 |
| 3×50+54.6+2×16 | 3×50 | 7 | 8.4 | 0.641 | 168 | 2×16 | – | 9.6 | 16 | 0.63 | 36 | 890 |
| 3×70+54.6 | 3×70 | 14 | 10.0 | 0.443 | 213 | – | – | 9.6 | 16 | 0.63 | 38 | 930 |
| 3×70+54.6+1×16 | 3×70 | 14 | 10.0 | 0.443 | 213 | 1×16 | 60 | 9.6 | 16 | 0.63 | 38 | 1030 |
| 3×70+54.6+2×16 | 3×70 | 14 | 10.0 | 0.443 | 213 | 2×16 | – | 9.6 | 16 | 0.63 | 38 | 1100 |
| 3×70+54.6+1×25 | 3×70 | 14 | 10.0 | 0.443 | 213 | 1×25 | – | 9.6 | 16 | 0.63 | 40 | 1070 |
| 3×70+54.6+2×25 | 3×70 | 14 | 10.0 | 0.443 | 213 | 2×25 | – | 9.6 | 16 | 0.63 | 40 | 1170 |
| 3×70+70 | 3×70 | 14 | 10.0 | 0.443 | 213 | – | – | 10.2 | 20.6 | 0.50 | 41 | 970 |
| 3×70+70+1×16 | 3×70 | 14 | 10.0 | 0.443 | 213 | 1×16 | 60 | 10.2 | 20.6 | 0.50 | 41 | 1080 |
| 3×70+70+2×16 | 3×70 | 14 | 10.0 | 0.443 | 213 | 2×16 | – | 10.2 | 20.6 | 0.50 | 41 | 1150 |
| 3×95+70 | 3×95 | 19 | 11.5 | 0.320 | 258 | – | – | 10.2 | 20.6 | 0.50 | 44 | 1200 |
| 3×95+70+1×16 | 3×95 | 19 | 11.5 | 0.320 | 258 | 1×16 | 60 | 10.2 | 20.6 | 0.50 | 44 | 1300 |
| 3×95+70+2×16 | 3×95 | 19 | 11.5 | 0.320 | 258 | 2×16 | – | 10.2 | 20.6 | 0.50 | 44 | 1380 |
| 3×120+70 | 3×120 | 19 | 13.0 | 0.253 | 300 | – | – | 10.2 | 20.6 | 0.50 | 46 | 1430 |
| 3×120+70+1×16 | 3×120 | 19 | 13.0 | 0.253 | 300 | 1×16 | 60 | 10.2 | 20.6 | 0.50 | 46 | 1540 |
| 3×120+70+2×16 | 3×120 | 19 | 13.0 | 0.253 | 300 | 2×16 | – | 10.2 | 20.6 | 0.50 | 46 | 1600 |
| 3×150+70 | 3×150 | 19 | 14.5 | 0.206 | 344 | – | – | 10.2 | 20.6 | 0.50 | 48 | 1680 |
| 3×150+70+1×16 | 3×150 | 19 | 14.5 | 0.206 | 344 | 1×16 | 60 | 10.2 | 20.6 | 0.50 | 48 | 1780 |
| 3×150+70+2×16 | 3×150 | 19 | 14.5 | 0.206 | 344 | 2×16 | – | 10.2 | 20.6 | 0.50 | 48 | 1850 |
| 3×120+95 | 3×120 | 19 | 13.0 | 0.253 | 300 | – | – | 12.9 | 27.9 | 0.343 | 47 | 1500 |
| 3×120+95+1×16 | 3×120 | 19 | 13.0 | 0.253 | 300 | 1×16 | 60 | 12.9 | 27.9 | 0.343 | 47 | 1620 |
| 3×120+95+2×16 | 3×120 | 19 | 13.0 | 0.253 | 300 | 2×16 | – | 12.9 | 27.9 | 0.343 | 47 | 1680 |
| 3×150+95 | 3×150 | 19 | 14.5 | 0.206 | 344 | – | – | 12.9 | 27.9 | 0.343 | 49 | 1740 |
| 3×150+95+1×16 | 3×150 | 19 | 14.5 | 0.206 | 344 | 1×16 | 60 | 12.9 | 27.9 | 0.343 | 49 | 1880 |
| 3×150+95+2×16 | 3×150 | 19 | 14.5 | 0.206 | 344 | 2×16 | – | 12.9 | 27.9 | 0.343 | 49 | 1940 |
Packing
Steel wooden drum (fumigation)
Cable length in each drum: 1000m/2000m or as per actual cable length requirements.
Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Hongda cable Co., Ltd. is one of the most professional cable & wire producer, which was founded in 1988, have exported for 9 years, integrating scientific research, development, production and sales. Henan Hongda Cable Co., is the original Zhengzhou Hongda Cable Co., The company mainly produces 1-35 kV power cable, TW, THW, THHW, THHN electrical wire, ABC cable, Overhead Cable, AAC, AAAC, ACSR, ACAR bare conductor, Concentric Cable, etc
Our advantages
1. With more than 17 years manufacturing experience, our products are strictly in accordance with ISO, SGS, CCC ;
2. Good cost-control system, with highly-competitive prices;
3. Strong and Professional R&D team to meet your specific needs;
4. Fast delivery&reliable products are always the reason why you choose us.
Custom Merchandise: we can make cable as your need include the color ,size and so on.we also offer OEM
Tel: +86 371 6097 5619
Fax: +86 371 6097 5616
Whats App: +86 15037165923
Wechat:+86 15037165923
Mobile: +86 15037165923
Skype : zzhongdacable2