2X10mm2 Copper Conductor PVC Insulated SEU SER SE Concentric Cable

Port: | Qingdao or Any port in China |
Payment Terms: | L/C,T/T |
Supply Ability: | 3000000 Meter/Meters per Week |
Place of Origin: | Henan China |
Brand Name: | Yifang |
Model Number: | SEU, SER |
Insulation Material: | PVC |
Type: | Low Voltage |
Application: | Service-entrance |
Conductor Material: | Copper |
Jacket: | PE |
Rated voltage: | 600/1000V |
Delivery Detail: | According to client's request, usually 2 weeks |
Packaging Detail: | Wooden or iron drum or as your requirement |
Aluminum concentric cable
1. Application
The cable are for the service-entrance.
2. Construction
Rated Voltage: 600/1000V
Conductor: Solid or standed Al conductor
Insulation: XLPE, PVC, PE
Neutral conductor: Helically Al wire with coverage 100% and non-100% coverage
External coverage: Weather resistant material, XLPE, PVC, PE
Copper concentric cable
Service Entrance Cable, Type SE, In flat and In round cable, 600V
Concentric conductor with 100% and non 100% coverage
Indicidual Conductor Rated XHHW-2 or THW
Jacket and Individual Conductor Sunlight Resistant
1. Appliction
These requiremnets cover Type USE and USE-2 (below-ground) and Type SE (above-ground) power cable for installation in accordance with Article 338 and other applicable parts of the National Electrical Code (NEC). These cables are for the service-entrance and other (NEC) uses described in 1.4 1.8. In a multiple-conductor cable that is other than submersible-pump cable and does not have a grounding conductor it is appropriate to have one circuit conductor without insulation. It is also appropriate for a sunmersibe pump cable to have a grounding conductor and for Type USE and USE-2 cables to have an insulated grounding conductor. Each insulated conductor in these cables is rated for 600V. Type USE cable has thermose insulation, except for HDPE portion of HDPE-over-XLPE insulation where used for single-conductor Type USE cable. Type USE cable has thermoset or thermoplatic insulation.
2. Specification
Type SE cable meets or exceeds UL Standard 44 for XHHW-2 conductors or UL 83 for THW conductors, UL Standard 854.
3. Construction
Type SE cable is constructed with sunlight resistant Type XHHW-2 conductor or Type THW conductors. Copper conductors are annealed (soft) copper. Cable assembly plus reinforcement tape are jacketed with sunlight resistant thermoset or thermoplastic material, available as 1 conductor with a concetric ground, 2 conductor with a round and flat or concentric round, or 3 conductor with a bare ground. SE cable is jacketed with gray sunlight resistant thermoset or thermoplastic material.
4. Type
Single core type round with full neutral entrance cable
Single core type round with less neutral entrance cable
Single core type round with full neutral and communication cores entrance cable
Two core type Flat with full neutral entrance cable
Two core type round with full neutral entrance cable
Three core type round with full neutral and communication cores entrance cable
Three core type round with less neutral entrance cable
- Next: 3X240mm2 Copper Conductor XLPE Insulated N2XSEY Power Cable
- Previous: 600/1000V PVC Insulation And Sheath Control Cable