16mm earth wire

Port: | Qingdao |
Payment Terms: | L/C,T/T,Western Union,MoneyGram |
Supply Ability: | 5000 Kilometer/Kilometers per Day 16mm earth wire |
Place of Origin: | Hebei China |
Brand Name: | Haohua |
Model Number: | 16mm earth wire |
Type: | Insulated |
Application: | Overhead |
Conductor Material: | Copper |
Conductor Type: | Solid |
Insulation Material: | PVC |
Feature: | Single Core, Copper |
Conductor: | single core(soil or standed) |
Voltage: | 450/750V |
Approx. overall size: | Copper 1.5 - 400mm2 |
Application1: | 16mm earth wire |
Application2: | 16mm earth wire |
Max operating temp.: | 70°C |
Color: | yellow,red,blue,green,double color and so on |
Delivery Detail: | Within 7days after payment for 16mm earth wire |
Packaging Detail: | we packed it by roll, 100m/roll.or as your request for 16mm earth wire |
Copper house wiring electrical cable 16mm earth wire
If you can not find 16mm earth wire you need, pls don't worry, pls feel free to contact :
Echo Wang
skype: hongliangcablesales7
0086-15106980528
echo(at)hldlcable.com
16mm earth wire Simple Specification
1) Conductor:Cu
2) Type: Solid or Stranded
3) Insulation: PVC
4) Low Voltage:450/750V
5) Production Range:1.5mm2~400mm2
6) Standard: IEC60227 or BS 6004
16mm earth wire APPLICATION
For separate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. |
STANDARD |
IEC60227-3:1997 |
CODEDESIGNATION |
60227 IEC 01 (BV, Cu/PVC) |
|
VOLTAGE |
450/750V |
|
CONDUCTOR |
Copper 1.5 – 185mm2 |
|
INSULATION |
PVC/C See below for colour options |
|
MAX. OPERATING TEMP. |
70°C |
|
For separate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. |
STANDARD |
AS/NZS 5000.1 |
VOLTAGE |
600/1000V |
|
CONDUCTOR |
Copper 1 – 240mm2 |
|
INSULATION |
PVC, V-90 See below for colour options |
|
MAX. OPERATING TEMP. |
90°C |
16mm earth wire TECHNICAL SPECIFICATIONS–— IEC60227-3:1997
ITEM NUMBER |
CONDUCTOR |
NOMINAL INSULATION THICKNESS /mm |
APPROX. OVERALL DIAMETER /mm |
APPROX. MASS
kg/km |
MINIMUM INSTALLED RADIUS /mm |
||||
mm2 |
No./mm |
||||||||
1000xxx |
1.5 |
1/1.38 |
0.7 |
2.78 |
21.1 |
18 |
|||
1001xxx |
1.5 |
7/0.52 |
0.7 |
2.96 |
21.9 |
18 |
|||
1002xxx |
2.5 |
1/1.78 |
0.8 |
3.38 |
32.9 |
20 |
|||
1003xxx |
2.5 |
7/0.68 |
0.8 |
3.64 |
34.9 |
20 |
|||
1004xxx |
4 |
1/2.25 |
0.8 |
3.85 |
48.0 |
23 |
|||
1005xxx |
4 |
7/0.85 |
0.8 |
4.15 |
49.9 |
23 |
|||
1006xxx |
6 |
1/2.76 |
0.8 |
4.36 |
67.9 |
26 |
|||
1007xxx |
6 |
7/1.04 |
0.8 |
4.72 |
70.2 |
26 |
|||
1008xxx |
10 |
1/3.56 |
1.0 |
5.56 |
111.4 |
33 |
|||
1009xxx |
10 |
7/1.34 |
1.0 |
6.02 |
114.8 |
33 |
|||
1010xxx |
16 |
7/1.68 |
1.0 |
7.04 |
171.1 |
42 |
|||
1011xxx |
25 |
7/2.12 |
1.2 |
8.76 |
268.9 |
53 |
|||
1012xxx |
35 |
7/2.50 |
1.2 |
9.90 |
363.1 |
59 |
|||
1013xxx |
50 |
19/1.76 |
1.4 |
11.60 |
488.8 |
70 |
|||
1014xxx |
70 |
19/2.12 |
1.4 |
13.40 |
690.1 |
80 |
|||
1015xxx |
95 |
19/2.50 |
1.6 |
15.70 |
954.8 |
94 |
|||
1016xxx |
120 |
37/2.00 |
1.6 |
17.20 |
1174.9 |
103 |
|||
1017xxx |
150 |
37/2.22 |
1.8 |
19.14 |
1448.7 |
115 |
|||
1018xxx |
185 |
37/2.48 |
2.0 |
21.36 |
1805.7 |
128 |
|||
• xxx=001 for Black |
• xxx=002 for Blue |
• xxx=003 for Brown |
• xxx=004 for Grey |
||||||
• xxx=005 for Red |
• xxx=006 for Green/Yellow |
• xxx=007 for Green |
• xxx=008 for Yellow |
||||||
|
TECHNICAL SPECIFICATIONS—AS/NZS 5000.1
ITEM NUMBER |
CONDUCTOR |
OVERALL DIAMETER |
APPROX. MASS kg/km |
MINIMUM INSTALLED RADIUS mm |
|||||
mm2 |
No./mm |
MINIMUM mm |
MAXIMUM mm |
||||||
10100xxx |
1 |
1/1.13 |
2.7 |
2.9 |
20 |
20 |
|||
10120xxx |
1.5 |
7/0.50 |
3.1 |
3.3 |
25 |
20 |
|||
10140xxx |
2.5 |
7/0.67 |
3.6 |
3.7 |
35 |
25 |
|||
10165xxx |
4 |
7/0.85 |
4.5 |
4.7 |
55 |
30 |
|||
10183xxx |
6 |
7/1.04 |
5.1 |
5.2 |
70 |
35 |
|||
10200xxx |
10 |
7/1.35 |
5.9 |
6.1 |
120 |
40 |
|||
10220xxx |
16 |
7/1.70 |
6.8 |
7.1 |
180 |
45 |
|||
12200xxx |
25 |
7/2.14 |
8.8 |
9.1 |
260 |
60 |
|||
12220xxx |
35 |
19/1.53 |
10.1 |
10.3 |
370 |
65 |
|||
12240xxx |
50 |
19/1.78 |
11.7 |
12.1 |
515 |
70 |
|||
12260xxx |
70 |
19/2.14 |
13.5 |
13.8 |
730 |
80 |
|||
12280xxx |
95 |
37/1.78 |
15.7 |
16.1 |
970 |
90 |
|||
12300xxx |
120 |
19 strands |
16.1 |
16.5 |
1250 |
100 |
|||
12320xxx |
150 |
19 strands |
17.9 |
18.3 |
1500 |
110 |
|||
12327xxx |
185 |
19 strands |
19.9 |
20.4 |
1800 |
125 |
|||
12328xxx |
240 |
19 strands |
22.7 |
23.3 |
2400 |
140 |
|||
• xxx=016 for Black |
• xxx=021 for Blue |
• xxx=028 for Brown |
• xxx=096 for Grey |
||||||
• xxx=131 for Qrange |
• xxx=153 for Pink |
• xxx=158 for Red |
• xxx=189 for Violet |
||||||
• xxx=199 for Black |
• xxx=403 for Green/Yellow |
• |
• |
||||||
Packing and shipping
For this general building wire, we packed it by roll, 100m/roll.
Besides, we can dish the building wire for many dishes, then packed in a carton with pallet.
Also we can customise your detailed requests.
PLS KINDLY ATTENTION:
Do not put in direct contact with polystyrene, polyurethane or similar thermal insulation materials.
WORKSHOP
If you have any question about 16mm earth wire ,
Pls feel free to contact me .
Echo Wang
skype: hongliangcablesales7
0086-15106980528
echo(at)hldlcable.com
- Next: Semi-conductive cross linkable compounds for MV cables up to 35kV