15kv 150mm2 xlpe underground armoured power cables single core or three phase MV copper aluminum cables

15kv 150mm2 xlpe underground armoured power cables single core or three phase MV copper aluminum cables
Port: Shanghai
Payment Terms: L/C,T/T
Supply Ability: 100000 Meter/Meters per Month
Place of Origin: Shanghai China
Brand Name: SAHN, OEM
Model Number: YJV32/YJV22 below 35kV
Insulation Material: XLPE
Type: Medium Voltage
Application: Power Station
Conductor Material: Copper/Aluminum
Jacket: PVC, PE, LSOH
Product name: 15kv 150mm2 xlpe underground armoured power cables
Conductor: Pure Copper
Core: 1, 3
Rated voltage: 15kV
Insulation: XLPE
Special requiremets: Armour, LSZH, Fire-resistant
Certificates: CE, RoHS, CCC, KEMA
Warranty: 2 years since delivery
Standard: IEC60502
Packaging Detail: wooden drums according to quantity and container or required

15kv 150mm2 xlpe underground armoured power cables single core or three phase MV copper aluminum cables

15kv 150mm2 xlpe underground armoured power cables

Constructions

Conductor Compact Stranded Copper Conductor, Class 2 as per IEC 60228
Circular solid Copper Conductor, Class 1 as per IEC 60228
Flexible Stranded Copper Conductor, Class 5 as per IEC 60228
Conductor Screen Semi-conductor (MV only)
Insulation XLPE(Cross-linked polyethylene)
Insulation Screen Semi-conductor (MV only)
Metalic Shield Copper Tape Screen or Copper wire & copper tape Shield (MV must, LV optional)
Filler Fillers strip
Wrapping Tape Non woven wrapping tape or lsoh wrapping tape
Inner Covering Extruded PVC, or LSOH (MV only)
Armour Steel Tape Armour, Steel Wire or Aluminium Wire Armor optional
Overall Sheath PVC, FR-PVC, PE or LSOH

 

 

YJ: XLPE insulation

V: PVC sheath

32: Steel wire armoring—3 cores

22: Steel tape armoring—3 cores

72: Aluminum wire armoring—1 core

62: Stainless steel tape armoring—1 core

ZR: Flame resistant

 

 

MV(6 to 35kv) Power Cable Details

 

 

This product is applicable to the power transmission and distribution line with AC rated voltage(U0/U) of 3.6/6kV-26/36kV system.It is routed in air (cable bridge frame,indoor wall support,and tray) and soil(direct buried, cable trench,pipe ect.) respectively according to difference of the protection layer structure. 

 

 
 
 
MV(11kv 15kv 33kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV No.of Core Conductor cross-section area(mm2)
xlpe insulation 1 core 3 core 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu core
YJV, N2XSY;PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable
Al Core
YJLV, NA2XSY; PVC sheathed power cable
YJLV22;steel tape armoured,PVC sheathed power cable
YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable

 

 

 

 

Application

 

 

Used in transformer stations, switching blocks, in electric power plants and industrial plants. 

Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.

 

 

 

Standards

 

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

 

 

Technical data

– Power cable according to DIN VDE 0276 part 603, HD 620, IEC 60502, BS 6622
– Temperature range max. to +90 °C
– Temperature during installation from 0 °C to +70 °C
– Short circuit temperature +250 °C (up to 5 seconds)
– Nominal voltage Uo/U 3,6/6 kV, 6/10 kV, 6,35/11 kV (dle BS), 18/30 kV, 19/33 kV (dle BS)
– Operating voltages 3,6/6 kV = max. 7,2 kV 6/10 kV = max. 12 kV 18/30 kV = max. 36 kV
– Test voltage a.c. 3,6/6 kV = 11 kV up to 5 min. 6/10 kV = 21 kV up to 5 min. 18/30 kV = 63 kV up to 5 min.
– Minimum bending radius approx. 15 cable diameter

 

Test voltage 6 / 10 kV [kV] 21 / 5 min.
  12 / 20 kV [kV] 42 / 5 min.
  18 / 30 kV [kV] 63 / 5 min.
Temperature range in motion   -5°C till +70°C
  fixed   -20°C till +70°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard   EN 60332-1-2

 

 

*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length

 

 

Certificate

 

ISO,CE, KEMA ,IEC, RoHS, CCC, P3C and more others at request

 

 

 

PACKING AND SHIPPING

 

All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum. The packing material is depended on the weight and size of cable. After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight. The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.

 

 

Services

♦ We are the one of biggest manufacture of electric wire and power cable in China and has more than 20 years producing and marketing experience.
♦ We accept OEM. The cable size and material are customized.Ur own logo and own design are welcome. We will produce according to your requirement and description;
♦ Please send us inquiry for more products info and we will give you feedback in 12 hours.

 

 

Feel free to contact pls!

 
Leading manufacturer of wires and cables in China, specializes in the field for more than 20 years, with 7 manufacturing bases, 21 factories that annual output amounts to 1100000 kms, Focus on Electric Power / Control / House Wiring / Flexible Fireproof / Instrumentation / Branch / Special cables, ACCC, ACSR, AAAC Conductor ect, can provide you good cables with Quality ensured & Price reasonable!

 

Sincerely wish to build a good business relationship with your honored company and fulfill win-win situation together!
 
 
 
 
Tags: , ,