12/20(24) kV Medium Voltage Power Cable 1C X 300mm2 Cu/XLPE/CTS/LDPE or LLDPE

| Port: | Tianjin | 
| Payment Terms: | L/C,T/T,Western Union | 
| Supply Ability: | 5000 Kilometer/Kilometers per Month | 
| Place of Origin: | Hebei China | 
| Brand Name: | HAOHUA | 
| Model Number: | medium voltage power cable | 
| Type: | Insulated | 
| Application: | Underground | 
| Conductor Material: | Copper | 
| Conductor Type: | Solid | 
| Insulation Material: | PVC | 
| Type: | Cu or Al /XLPE/CTS or CWS/PVC, Cu or Al /XLPE/CTS or CWS/PVC/SWA/PVC | 
| Voltage: | 3.6/6kV~26/35kV | 
| Cores: | 1C and 3C | 
| Range of Nominal cross section: | 25 mm2 ~ 630 mm2 | 
| Application: | power transmission and distribution lines | 
| Standard: | IEC 60502, BS 6622 | 
| Metallic screen: | Copper tape or Copper wire | 
| Armour: | Steel Wire Armour or Steel Tape Armour | 
| Sheath: | PVC, PE or LSZH | 
| Remark: | of flame retardant, fire resistance, environment friendly or other | 
| Delivery Detail: | Within 15 working days after order confirmed | 
| Packaging Detail: | Drum package with wooden board lagging | 
medium voltage power cable Medium Voltage Power Cable, 12/20(24) kV 1C X 300mm2 Cu/XLPE/CTS/LDPE or LLDPE
Medium Voltage Power Cable, 8.7/15(17.5) kV 1C X 300mm2 Cu/XLPE/CTS/LDPE or LLDPE
Medium Voltage Power Cable, 8.7/15(17.5) kV 1C X 300mm2 Cu/XLPE/CTS/LDPE or LLDPE
Medium Voltage Power Cable, 8.7/15(17.5) kV 1C X 300mm2 Cu/XLPE/CTS/LDPE or LLDPE
IEC60502, and BS6346, VDE, AS/NZS, UL, etc or as customer's request.
2.The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
3.Application:
3x16mm2 power cable are most suitable for direct burial or for installation on trays or ducts, Where there is a risk of mechanical damage, armoured cables should be used.
4.Construction:
YJV32 6.6/11KV ~ 8.7/15kV
Copper(aluminum)conductor or conductor screen
XLPE insulation or insulation screen
Color for core identification
Assembly/beding/armoured/outer sheath.
5.Description for YJV YJLV
| Items | Description | Application | Core | Section | 
| YJV | Copper core XLPE insulated PVC sheathed power cable | Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull | 1 2 3 | 1.5-600mm2 | 
| YJY YJLY | Copper core XLPE insulated PVC sheathed power cable | Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull | 1 2 3 4 | 1.5-600mm2 | 
| YJV22 YJLV22 | Copper core XLPE insulated Galvanized steel Tape armoured PVC sheathed Underground Copper Cable | Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull | 2 3 4 | 1.5-630mm2 | 
| YJV23 YJLV23 | Copper core XLPE insulated Galvanized steel Tape armoured PE sheathed Underground Copper Cable | Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull | 3 4 5 3+1 4+1 | 1.5-630mm2 | 
| YJV32 YJLV32 | Copper core XLPE insulated Galvanized steel wire armoured PVC sheathed Underground Copper Cable | Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull | 2 3 4 5 3+1 4+1 | 1.5-630mm2 | 
| YJV33 YJLV33 | Copper core XLPE insulated Galvanized steel wire armoured PE sheathed Underground Copper Cable | Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull | 2 3 4 5 3+1 4+1 | |
| ZR =Flame Rerardent | ZR-YJV ZR-YJLV YJV22 YJLV22 YJV32 YJLV32 | SAME WITH ABOVE | SAME | SAME | 
| Medium Voltage Power Cable, 12/20(24) kV  1C X 300mm2 Cu/XLPE/CTS/LDPE or LLDPE | |||||||||
| No. | Description | Unit | Particulars | ||||||
| 1 | Size | 1C x 300mm2 | |||||||
| 10 | Overall diameter of the cable | mm | 39 | ||||||
| 11 | Minimum Bending radius | mm | 468 | ||||||
| 12 | Cable Weight approx. | kg/km | 3700 | ||||||
| 13 | AC Test voltage (No breakdown) | kV/5min | 42 | ||||||
| 14 | Maximum allowable conductor temperature at full load and short circuit condition | ℃ | 90/250 | ||||||
| 15 | Packing | ||||||||
| 15.1 | Drum Length | m | 3000 | ||||||
| 15.2 | Drum Dimension | mm | 2500*1250*2000 | ||||||
| 15.3 | Gross weight of drum with cable | kg | 11700 | ||||||
| 15.4 | Drum Material | – | Steel Drum | ||||||
| 16 | Structure chart | ||||||||
| 1. Parameters can be changed according to your requirement such as color of insulation or others. | |||||||||
| 2. Parameters may be a little different due to other factors in the process of production. | |||||||||
  
- Next: Power Cable 0.6/1kV Low Voltage Cu/XLPE/PVC 2 x 4mm2 2 x 6mm2 2 x 10mm2
- Previous: Medium Voltage Cables for highway lightining