1.5mm2 copper conductor pvc insulated control cable

1.5mm2 copper conductor pvc insulated control cable
Port: Qingdao, Shanghai, Ningbo, Tianjin, Guangzhou, Dalian, Shenzhen, Yingkou
Payment Terms: L/C,D/P,T/T,Western Union,MoneyGram,Paypal payment also accept of the control cable
Supply Ability: 1000 Kilometer/Kilometers per Month The quantity depending on the control cable size.
Place of Origin: Henan China
Brand Name: Hongda
Model Number: KVVP
Application: Telecommunication
Conductor Material: Copper
Jacket: PVC
Insulation Material: PVC
Rated Voltage: 0.6/1kV
Application: Industrial and overhead
Stranded: IEC,DIN,ASTM,BS,UL Standard
Insulation: PE/PVC/XLPE
Core: Multi-core abc cable
Certificate: ISO9001/CCC
Packing: Wooden Drum
Conductor Material: Copper/pure copper/solid copper
Armour: Steel Wire Armour
Conductor Type: 2 Stranded copper conductor
Packaging Detail: control cable for export wooden drum, wooden iron drum or other export standard package. We can also pack it according to your requirement.

1.50mm2 copper conductor pvc insulated control cable

pvc insulated control cable

Type Description Main Application
KVVZR-KVVGZR-KZZ
NH-KVVKVVR-ZR-KVVR
Fire-resistant,flame-retardant or ordinary PVC insulated and PVC sheathed control cable. For laying indoors,in trenches,in ducts and in ground.  copper conductor control cable
KVV22ZR-KVV22
GZR-KVV22NH-KVV22
Fire-resistant,flame-retardant or ordinary PVC insulated and PVC sheathed,steel tape armored control cable. For laying indoors,in trenches,in ducts and in ground,able to bear external mechanical forces.
KVVPKVVP2ZR-KVVP
ZR-KVVP2KVVRPZR-KVVRP
Flame-retardant or ordinary PVC insulated,PVCsheathed, control cable. For laying indoors,in trenches,in ducts and in ground,with antiinter ference ability.
KYJVZR-KYJV
GZR-KYJVNH-KYJV
Fire-resistant,flame-retardant or ordinary XLPE insulated,PVC sheathed control cable. For laying indoors,in trenches,in ducts and in ground.  copper conductor control cable
KYJV22ZR-KYJV22
GZR-KYJV22NH-KYJV22
Fire-resistant,flame-retardant or ordinary XLPE insulated,PVC sheathed and steel tape armored control cable. For laying indoors,in trenches,in ducts and in ground,able to bear external mechanical forces.
KVVP2-22
KVVP22
Copper-cpre PVC insulated,PVC sheathed copper tape and steel tape armored double-shield control cable. Be applicable for weak electricity control system and strong electromagnetic field jamming area.

Note:ZR-flame retardant    G-Oxygen barrier    NH-fire resistant

pvc insulated control cabl

The rated voltages 450/750V PVC and 0.6/1kv XLPE control are used for the controlling,return circuit and protecting facilities for the rated voltages 450/750V and 0.6/1kV separtely.The working temperature of PVC and XLPE control cables are 70 and 90 separately.
   Our factory developes 0.6/1kV XPLE insulated control cable based on PVC insulated and sheathed control cable for rated voltage 450/750V PVC.The flame retardant and fird resistant PVC/XLPE insulated control cable.

 450/750V PVC insulated control cables are in accordance with the GB9330-88.0.6/1kV XLPE insulated control cable meets IEC60502.1.The electrical properties of flame retardant

is accordance with GB9330 Plastic insulated control cable.The property of flame retardant meets the requirements of class A,B or C of GB/T12666.5-90 Test on bunched wires or cable correspondingly.The property of fire resistant meets the class A or B requirements of the GB/T12666.6-90 Test on fire resisting characteristics of wire or cable.

pvc insulated control cable

Package

Other Products:

 All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

 (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228

(AAAC) Conductor as per ASTM-B-399-1992

(AAAC) Conductor as per BS-3242-1970

(AAAC) Conductor IS: 398-IV-1994

(ACSR) as per ASTM-B-233-1992

(AAC) as per BS-215-1-1970  aaac bare conductor

(AAC) as per IS-398-1: 1976

(AAC) as per ASTM-B-231-1990

(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992

(ACSR) BS-215-II-1970  aaac bare conductor

(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.  copper conductor control cable

 

Applications:

Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.  copper conductor control cable

 

pvc insulated control cable

4. Specifications:

ACSR bare conductor meets or exceeds the following ASTM specifications:

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes

B-231 Aluminum Conductors, Concentric-Lay-Stranded  aaac bare conductor

B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)

B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)

B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)

B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Area Stranding and wire Diameter Overall Diameter
Norminal Actual

Alu/steel

mm2

Alu

mm2

Steel

mm2

Total

mm2

Aluminum

mm

Steel

mm

mm
16/2.5 15.3 2.5 17.8 6/1.80 1/1.80 5.4
25/4.0 23.8 4.0 27.8 6/2.25 1/2.25 6.8
35/6.0 34.3 5.7 40.0 6/2.70 1/2.70 8.1
44/32.0 44.0 31.7 75. 14/2.00 7/2.40 11.2
50/8.0 48.3 8.0 56.3 6/3.20 1/3.20 9.6
50/30 51.2 29.8 81.0 12/2.33 7/2.33 11.7
70/12 69.9 11.4 81.3 26/1.85 7/1.44 11.7
95/15 94.4 15.3 109.7 26/2.15 7/1.67 13.6
95/55 96.5 56.3 152.8 12/3.20 7/3.20 16.0
105/75 105.7 75.5 181.5 14/3.10 19/2.25 17.5
120/20 121.6 19.8 141.4 26/2.44 7/1.90 15.5
125/30 127.9 29.8 157.7 30/2.33 7/2.33 16.3
120/70 122.0 71.3 193.3 12/3.60 7/3.60 18
150/25 148.9 24.2 173.1 26/2.70 7/2.10 17.1
170/40 171.8 40.1 211.9 30/2.70 7/2.70 18.9
185/30 183.8 29.8 213.6 26/3.00 7/2.33 19.0
210/35 209.1 34.1 243.2 26/3.20 7/2.49 20.3
210/50 212.1 49.5 261.6 30/3.00 7/3.00 21.0
230/30 230.9 29.8 260.7 24/3.50 7/2.33 21.0
240/40 243.0 39.5 282.5 26/3.45 7/2.68 21.9
265/35 263.7 34.1 297.8 24/3.74 7/2.49 22.4
300/50 304.3 49.5 353.7 26/3.86 7/3.00 24.5

pvc insulated control cable

ABC Cable With AAAC Messenger Core

Spec.

mm2

Conductor structure Insulation Material Insulation Thickness (mm) Packing Meters per Drum
Phase (Compacted AL) Neutral (Alloy)
(No./mm)

Aluminum

(No./mm)

1×16+1×16 7/1.72 7/1.72

XLPE (HDPE)

copper conductor control cable

1.2 250-4000m
1×25+1×25 7/2.15 7/2.15 1.2 250-4000m
1×35+1×35 7/2.54 7/2.54 1.4 250-3500m
1×50+1×50 7/2.92 7/2.92 1.4 250-3000m
1×70+1×70 19/2.15 19/2.15 1.4 250-3000m
1×95+1×95 19/2.54 19/2.54 1.6 250-3000m
2×16+1×16 7/1.72 7/1.72 1.2 250-4000m
2×25+1×25 7/2.15 7/2.15 1.2 250-3500m
2×35+1×35 7/2.54 7/2.54 1.4 250-3500m
2×50+1×50 7/.292 7/2.92 1.4 250-3000m
2×70+1×70 19/2.15 19/2.15 1.4 250-3000m
2×95+1×95 19/2.54 19/2.54 1.6 250-3000m
3×16+1×16 7/1.72 7/1.72 1.2 250-3500m
3×25+1×25 7/2.15 7/2.15 1.2 250-3500m
3×35+1×35 7/2.54 7/2.54 1.4 250-3000m
3×50+1×50 7/2.92 7/2.92 1.4 250-3000m
3×70+1×70 19/2.15 19/2.15 1.4 250-3000m
3×95+1×95 19/2.54 19/2.54 1.6 250-3000m

pvc insulated control cable

ABC Cable Without Messenger Core

Spec.

mm2

Conductor structure Insulation Material Insulation Thickness (mm) Packing Meters per Drum

Compacted  Aluminum

(No./mm)

2×16 7/1.72

XLPE (HDPE)

copper conductor control cable

1.2 250-4000m
2×25 7/2.15 1.2 250-4000m
2×35 7/2.54 1.4 250-3500m
2×50 7/2.92 1.4 250-3000m
2×70 19/2.15 1.4 250-3000m
2×95 19/2.54 1.6 250-3000m
3×16 7/1.72 1.2 250-4000m
3×25 7/2.15 1.2 250-3500m
3×35 7/2.54 1.4 250-3500m
3×50 7/.292 1.4 250-3000m
3×70 19/2.15 1.4 250-3000m
3×95 19/2.54 1.6 250-3000m
4×16 7/1.72 1.2 250-3500m
4×25 7/2.15 1.2 250-3500m
4×35 7/2.54 1.4 250-3000m
4×50 7/2.92 1.4 250-3000m
4×70 19/2.15 1.4 250-3000m
4×95 19/2.54 1.6 250-3000m

pvc insulated control cable

ABC Cable With ACSR Messenger Core

Spec.

mm2

Conductor structure Insulation Material Insulation Thickness (mm) Packing Meters per Drum
Phase (Compacted AL) Neutral (Bare ACSR)  
(No./mm)

Aluminum

(No./mm)

Steel

(No./mm)

1×16+1×16 7/1.72 6/1.72 1/1.72 XLPE (HDPE) 1.2 250-4000m
1×25+1×25 7/2.15 6/2.15 1/2.15 1.2 250-4000m
1×35+1×35 7/2.54 6/2.54 1/2.54 1.4 250-3500m
1×50+1×50 7/2.92 6/2.92 1/2.92 1.4 250-3000m
1×70+1×70 19/2.15 12/2.15 7/2.15 1.4 250-3000m
1×95+1×95 19/2.54 12/2.54 7/2.54 1.6 250-3000m
2×16+1×16 7/1.72 6/1.72 1/1.72 1.2 250-4000m
2×25+1×25 7/2.15 6/2.15 1/2.15 1.2 250-3500m
2×35+1×35 7/2.54 6/2.54 1/2.54 1.4 250-3500m
2×50+1×50 7/.292 6/2.92 1/2.92 1.4 250-3000m
2×70+1×70 19/2.15 12/2.15 7/2.15 1.4 250-3000m
2×95+1×95 19/2.54 12/2.54 7/2.54 1.6 250-3000m
3×16+1×16 7/1.72 6/1.72 1/1.72 1.2 250-3500m
3×25+1×25 7/2.15 6/2.15 1/2.15 1.2 250-3500m
3×35+1×35 7/2.54 6/2.54 1/2.54 1.4 250-3000m
3×50+1×50 7/2.92 6/2.92 1/2.92 1.4 250-3000m
3×70+1×70 19/2.15 12/2.15 7/2.15 1.4 250-3000m
3×95+1×95 19/2.54 12/2.54 7/2.54 1.6 250-3000m

pvc insulated control cable

Notes:

Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.

Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

pvc insulated control cable

 

Packaging & Shipping

 

5. Packaging & shipping

pvc insulated control cable

Packaging Detail: export wooden drum pack bare acsr conductor, wooden iron drum and other export standard package
Delivery Detail: 10 days and also depend on the quantity

Drum Handling Practices

DO'S

  • Cradle both drum flanges between forks.
  • Drums can be hoisted with a shaft extending through both flages.
  • Lower drums from truck using hydraulic gate, hoist or fork lift. LOWER CAREFULLY.
  • Always load with flanges on edge and chock and block securely.  copper conductor control cable

DONT'S

  • Upended heavy drums will often arrive damaged. Refuse or receive subject to inspection for hidden damages.
  • Do not lift by top flange. Conductor or drum will be damaged.
  • Never allow forks to touch conductor surface or reel wrap.
  • Never drop drums.  copper conductor control cable

abc cable

Our Services

 

6. Our Advantages:

we can offer the sample free .

  • Excellent electric and mechanical characteristics.
  • Good conductivity,Resistance chemical corrosion and heat-ageing,environment stress.
  • Unit volume light,Simple in structure.
  • Convenient to use,especially for laying across rivers and valleys where special geographical terrain exist.

we are the top of ten manufacture in china mainland. We will give you a perfect shopping experience . If you need visit our factory , we will meet you at the airport or train station.
Also we can offer other service
Custom Merchandise: we can make cable as your need include the color ,size and so on.we also offer OEM .
Complete Course Tracking: we can offer you the service from the business begin to you get the cable and use it .

copper conductor control cable

Company Information

 

7. Company information
Zhengzhou hongda cable Co., Ltd.
Established Year:1999
Registered capital of RMB:5,000,000
Factory Area:300,000m2
Main products: ABC cable Areial bundle cable ,XLPE insulated power cable ,PVC insulated power cable ,electrical wire ,bare aluminum conductor(AAC AAAC ACSR )and so on
Main export county: USA, Philippines, Malaysia, Indonesia, Venezuela, Colombia, Mexico, Dominica, India, South Africa, Zambia, Kenya and so on.

abc cable

Related Products:

ABC cable overhead Aerial Bundle Cable

fire resistance cable

underground cable with pvc insulation

450/750V BV electrical wire

ACSR bare conductor overhead power cable

We hope to establish a friendly relations with you, we will try our best to give you satisfication.
Any require contact me as follows:

pvc insulated control cable

Tags: , ,