1.5mm pvc insulated single core electric cable wire / single core cable construction cable wire
2.5mm 4mm 6mm 10mm 16mm 25mm 35mm 50mm 70mm2 95sqmm Single core Copper conductor PVC insulated Electircal Cable Wire
Specifications
Leading manfuacturer in china
Factory direct export
OEM available
Code designation: 60227 IEC 01 (International), BV (China), NYA(VDE)
1 Standard: BS6004 / IEC227 JB8734-98 GB/T5023-2008
2 Conductor: Solid, stranded or flexible annealed bare copper conductor
3 Insulation: Polyvinyl Chloride (PVC) Rated 70oC
4 Rated Voltage: 300/500V, 450/750V
5 Rated Temperature: -30oC~+90oC
6 Application: 1.5mm electrical cable / price are used for indoor wire of civil illumination and household appliance
and for installing of the equipment, instrument and power of 450/750V and below. In dry rooms, apparatus switch and distribution boards, for fixed installation in conduits, over and under plaster and on insulated supports over plaster. Direct laying in plaster is not permitted.
Technical Data Sheet
Class 1/2 Conductor
BV300/500V
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km |
| mm2 | mm | mm2 | kg/km | Ω /km |
| 0.5 | 1/0.80 | 2.3 | 8.5 | 36.0 |
| 0.75(A) | 1/0.97 | 2.5 | 11.1 | 24.5 |
| 0.75(B) | 7/0.37 | 2.6 | 12.0 | 24.5 |
| 1.0(A) | 1/1.13 | 2.7 | 13.9 | 18.1 |
| 1.0(B) | 7/0.43 | 2.8 | 15.0 | 18.1 |
BV / BLV (BV-105) 450/750V
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km | ||
| mm2 | mm | mm2 | kg/km | Ω /km | ||
| Copper | Aluminium | Aluminium | Copper | |||
| 1.5(A) | 1/1.38 | 3.2 | 20.3 | 12.1 | ||
| 1.5(B) | 7/0.52 | 3.3 | 21.6 | 12.1 | ||
| 2.5(A) | 1/1.78 | 3.9 | 31.6 | 17 | 11.8 | 7.41 |
| 2.5(B) | 7/0.68 | 4.0 | 34.8 | 7.41 | ||
| 4(A) | 1/2.55 | 4.4 | 47.1 | 22 | 7.39 | 4.61 |
| 4(B) | 7/0.85 | 4.6 | 50.3 | |||
BV/BLV(BV-105) 450/750V
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km | ||
| mm2 | mm | mm2 | kg/km | Ω /km | ||
| Copper | Aluminium | Aluminium | Copper | |||
| 6(A) | 7/0.85 | 5.0 | 50.3 | 29 | 4.91 | 3.08 |
| 6(B) | 7/1.04 | 5.2 | 71.2 | 29 | 4.91 | 3.08 |
| 10 | 7/1.35 | 6.4 | 119 | 62 | 3.08 | 1.83 |
| 16 | 7/1.70 | 7.8 | 179 | 78 | 1.91 | 1.15 |
| 25 | 27/2.04 | 9.7 | 281 | 118 | 1.20 | 0.727 |
| 35 | 27/2.52 | 10.9 | 381 | 156 | 0.868 | 0.524 |
| 50 | 19/1.78 | 12.8 | 521 | 215 | 0.641 | 0.387 |
| 70 | 19/2.14 | 14.4 | 734 | 282 | 0.443 | 0.268 |
| 95 | 19/2.52 | 17.1 | 962 | 385 | 0.320 | 0.193 |
| 120 | 37/2.03 | 18.8 | 1180 | 431 | 0.253 | 0.153 |
| 150 | 37/2.25 | 20.9 | 1470 | 539 | 0.206 | 0.124 |
| 185 | 37/2.52 | 23.3 | 1810 | 666 | 0.164 | 0.0991 |
| 240 | 61/2.25 | 26.6 | 2350 | 857 | 0.125 | 0.0754 |
| 300 | 61/2.52 | 29.6 | 2930 | 1070 | 0.100 | 0.0601 |
| 400 | 61/2.85 | 33.2 | 3870 | 1390 | 0.0778 | 0.0470 |