0.6 / 1kv NF C 33-209 Al conductors XLPE insulation electrical cable for overhead lines

0.6 / 1kv NF C 33-209 Al conductors XLPE insulation electrical cable for overhead lines
Port: Qingdao
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,Credit guarantee
Supply Ability: 1000 Kilometer/Kilometers per Month NF C 33-209 electrical cable for overhead lines
Place of Origin: Henan China
Brand Name: Hongda
Model Number: NF C 33-209 ABC Cable
Insulation Material: XLPE
Type: Low Voltage
Application: Industrial
Conductor Material: Aluminum
Jacket: PVC
Product name: NF C 33-209 XLPE insulation electric cable for overhead lines
Conductor Material: AAC or AAAC or ASCR
Number of cores: 1 core, 2 cores, 3 cores, 4 cores, 5 cores
Conductor type: Stranded Aluminum Conductor
Insulation: XLPE Insulation NF C 33-209 ABC Cable
Rated Voltage: 0.6 / 1kv NF C 33-209 ABC Cable
Standard: NF C 33-209
Application: electrical installations with alternating power networks
Certificates: ISO9001
Delivery time: 7 - 15days
Delivery Detail: 12 days depend on the quantity
Packaging Detail: 0.6 / 1kv NF C 33-209 Al conductors XLPE insulation electrical cable for overhead lines length in each wooden drum: 500m/1000m or as per actual cable length requirements
Product Description

 

0.6 / 1kv NF C 33-209 Al conductors x LPE insulation electrical cable for overhead lines

 

Power cables with x LPE insulation for overhead lines

Al conductors • XLPE insulation

 

Standard: NF C 33-209 (HD 626 S1/A2: 2002 – 4E and 6E)

Description:

Al conductors • x LPE insulation

 

Application:

The x LPE insulation electrical cables with cross-linked polyethylene ( x LPE) insulation for overhead lines are designed for electrical installations with alternating power networks with nominal voltage Uo/U 0.6/1 kV or in direct power networks with ma x imum voltage according to land 0.9 kV.
The x LPE insulation electrical cable with supporting (bearing) zero conductors are used for building networks in city and urban areas and the self-supporting type cables are for building distribution networks in these areas.
x LPE insulation electrical cable for overhead installations may be used in different types of installations: on free hanging facades; between posts; on fi x ed facades; trees and poles. Interception of forest areas without the need of clearance and maintenance of openings is allowed.

  • – x LPE insulation electrical cable with supporting zero conductor, the whole bundle is suspended and carried by the supporting conductor, which is made of aluminum compound.
  • – Self-supporting construction, suspension and carrying of the whole bundle is done by the phase insulated conductors.
  • Bundles can include one or two additional conductors for public lighting and control pair.

 

Cable construction

Technical data

Construction According to NF C 33-209 Conductor resistance at 20° C According to NF C 33-209
Operating temperature 80° C continuous operation
Conductor
-phase(main) M
-neutral (supporting) N
-additional for lighting R
Al stranded compacted or Non-compacted according to NF C 33-209
AL stranded according to NF C 33-209
Al stranded compacted or non-compacted according to NF C 33-209

Overload temperature

130° C /100h/per year Ma x ./
Short circuit temperature 250° C /5 s ma x ./
Nominal voltage
AC
DC
Uo/U 0.6/1 kV
0.9 kV
Insulation x LPE with min. 2% carbon black content
Constructions twisted into a bundle include:
– phase (main) insulated cores(M)
– neutral supporting insulated core ( N )
– one, two, or three additional reduced insulated cores for lighting ( R )
Highest system voltage AC, not more tha 1.2 kV
Test voltage:
AC -15 min
DC – 15 min
4 kV
10 kV
Color black Bending radius, min 18 x D cable
Temperature of laying no less than – 10° C recommended 15 ° C
Marking raised with paint:
– phase ( M ) – with numbers 1;2;3
– supporting 0 core( N )
ELKABEL NF C 33-209 additional cores for lighting ( R ) – EP1 and EP2
Resistance at 20° C: 16 – 1.91 Ω/km 70 – 0.443Ω/km
25 – 1.20 Ω/km 95 – 0.320Ω/km
35 – 0.868Ω/km 120 – 0.253Ω/km
50 – 0.641Ω/km 150 – 0.206Ω/km
54.6Alm – 0.63Ω/km;70Alm- 0.5Ω/km; 95Alm – 0.343Ω/km
Supported neutral breaking strength min. for 54.6 – 16.6kN
for 70 – 20.50kN
for 95 – 27.50kN

 

 

XLPE insulation electrical cable for overhead lines Construction data

Number of conductors and nominal cross section

Thickness of insulation Diameter of bundle Approx . Allowed Current in Power Supply Networks Mass of Al cores approx . Cable Weight Approx .

n x mm2

mm mm A kg/km kg/km

3 x 25+54.6Alm

1.4/1.6

30

112

369

505

3 x 25+54.6Alm+K x 16

1.4/1.6/1.2

30

112 / 83

460

635

3 x 35+54.6Alm

1.6/1.6

33

138

455

615

3 x 35+54.6Alm+K x 16

1.6/1.6/1.4

33

138 / 83

546

745

3 x 50+54.6Alm

1.6/1.6

36

168

583

725

3 x 50+54.6Alm+K x 16

1.6/1.6/1.2

36

168 / 93

674

860

3 x 50+54.6Alm+K x 25

1.6/1.6/1.4

36

168 / 111

725

925

3 x 70+54.6Alm

1.8/1.6

37

213

754

950

3 x 70+54.6Alm+K x 16

1.8/1.6/1.2

40

213 / 83

845

1080

3 x 70+54.6Alm+K x 25

1.8/1.6/1.4

40

213 / 111

896

1150

 

 

 

 

 

 

3 x 70+70Alm

1.8/1.5

41

213

798

984

3 x 70+70Alm+K x 16

1.8/1.5/1.2

41

213 / 83

889

1115

3 x 70+70Alm+K x 25

1.8/1.5/1.4

41

213 / 111

940

1185

 

 

 

 

 

 

3 x 95+54.6Alm

1.8/1.6/

44

258

967

1195

3 x 95+54.6Alm+K x 16

1.8/1.6/1.2

44

258 / 83

1059

1325

3 x 95+54.6Alm+K x 25

1.8/1.6/1.4

44

258 / 111

1110

1355

 

 

 

 

 

 

3 x 95+70Alm

1.8/1.5

44

258

1011

1355

3 x 95+70Alm+K x 16

1.8/1.5/1.2

44

258 / 83

1102

1615

3 x 95+70Alm+K x 25

1.8/1.5/1.4

44

258 / 111

1154

1485

3 x 120+70Alm

1.8/1.5

46

300

1225

1445

3 x 120+70Alm+K x 16

1.8/1.5/1.2

46

300 / 83

4828

1575

3 x 120+70Alm+K x 25

1.8/1.5/1.4

46

300 /111

1368

1610

 

 

 

 

 

 

3 x 120+95Alm

1.8/1.6

47

300

1296

1535

3 x 120+95Alm+K x 16

1.8/1.6/1.2

47

300 / 83

1387

1660

3 x 120+95Alm+K x 25

1.8/1.6/1.4

47

300 / 111

1439

1735

 

 

 

 

 

 

3 x 150+70Alm

1.7/1.5/

48

344

1482

1670

3 x 150+70Alm+K x 16

1.7/1.5/1.2

48

344 / 83

1573

1795

3 x 150+70Alm+K x 25

1.7/1.5/1.4

48

344 / 111

1624

1870

 

 

 

 

 

0.6 / 1kv NFA2 x Power cables with x LPE insulation for overhead lines Process Machine:

 

0.6 / 1kv NFA2 x Power cables with x LPE insulation for overhead lines Quality Control:

 

 

Packaging & Shipping

Packing: 

Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.

Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!

Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.

Sea freight:
FOB/C&F/CIF quotation are all available.

 

 

Company Information

Company Profile

Hongda cable Co., Ltd. is one of the most professional cable & wire producer under modern enterprise system in China, which was founded in 1988, integrating scientific research, development, production and sales. The company mainly produces 1-35 kV power cable, ABC cable, AAC, AAAC, ACSR.

Our advantages

1.  With more than 17 years manufacturing e x perience, our products are strictly in accordance with ISO, CE, UL and BV;

2.  Good cost-control system, with highly-competitive prices;

3.  Strong and Professional R&D team to meet your specific needs;

4.  Fast delivery&reliable products are always the reason why you choose us.

 

Why Choose Us

1. We have a large production base, and advanced production equipment 
2.  Have an competitive price and high quality
3.  E x cellent after-sale service
4.  Attractive design and various styles
5.  Free issue:packaging list,invoice,CD installation
6.  Powerful technology R&D team
7.  Strict quality assurance system and perfect testing means
8.  Advanced process equipment
9.  Painted with powerful antiseptic Anticorrosion material paints
10. Delivery on  time
11. Our roller coaster sales to middle East,Africa,Russia,Southeast Asia, etc.
12.We have a good reputation in the overseas

FAQ

Q 1: I didn’t find the cable I need in this page?
A: Dear Friend, we supply customized service. So, you can contact me directly for the as follows information, I will reply you asap!

Q 2: What’s your minimum Order Quantity?
A: You are advised to please confirm with us as it is based on the specification of the cables. Normally, it is 100m for small electric wires. 500 to 1000 per drum for power cable.

Q 3: What’s your delivery time?
A: It depends on whether we just has the stock for your type. Or, it takes about 7 – 15 days for normal orders.

Q 4: How can I get a sample to check your quality?
A: After price confirmation, you can require for sample to check our quality. Sample is free, but the freight charge should be paid.

Q: What is your terms of payment ?
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shipment.

Contact Information

Contact information

 

Any needs or question ,please contact us ,we will be more pleasure to service you.

 

We are looking forward to your inquiry and nice cooperaton.

 

Tags: , ,

Contact us

 

 

 

Search

You May Like

  • No related articles