0.6/1KV LV AAC AAAC ABC cable electrical three phase overhead Aerial Bundle Cable size

0.6/1KV LV AAC AAAC ABC cable electrical three phase overhead Aerial Bundle Cable size
Port: Qingdao, Shanghai, Ningbo, Tianjin, Guangzhou, Dalian, Shenzhen, Yingkou
Payment Terms: L/C,D/P,T/T,Western Union,MoneyGram
Supply Ability: 60000 Kilometer/Kilometers per Month The capacity depending on aerial bundle cable size
Place of Origin: Henan China
Brand Name: Hongda
Model Number: aerial bundle cable size
Insulation Material: XLPE
Type: Low Voltage
Application: Overhead
Conductor Material: Aluminum
Jacket: PVC
Sheath color: Black or as your request
Application: Industrial and overhead
Standard: ASTM, BS, NFC, IEC, DIN Standard
Properties: High safety & competitive price
aerial bundle cable Rated voltage: 0.6/1KV low voltgate
Number of Cores: 12 3 4 5 6 core or as your required
aerial bundle cable size: AWG10 16 25 35 50 70 95 120 150
Insulation: PVC Insulation Control Cable
Reference Standard: NFC_33-209
Packaging Detail: ABC cable ( Aerial Bundle Cable) is adopt for export wooden drum, wooden iron drum or other export standard package. We can also pack it according to your requirement.

ABC Cable sample: we can offer the sample free.  If possible we also can be support the clip for fitting, pls feel free to contact me.

 

Product Description

 

0.6/1KV LV AAC AAAC ABC cable electrical three phase overhead Aerial Bundle Cable size

Aerial Bunched Cables are used in theft prone areas, or as a replacement of bare conductors in rural areas, forest, hilly terrains etc. These AB cables give highly reliable performance, good protection against line and ground fault and good adaptability. Manufactured from quality raw material, these cables are durable and are safe for different electrical environments. These functional cables are available in standard dimensions and can also be customized as per client's requirement.

 

Features:

  • HONGDA make Aerial Bunched Cable (ABC) is a novel concept for Overhead Power Distribution System
  • HONGDA make Aerial Bunched Cable are designed, manufactured & tested conforming to IS: 14255, IS: 7098 (P-I) & other international specifications like IEC, NFC etc.

Applications:

ABC can conveniently be used:

  • In theft prone areas
  • As replacement of bare conductors in rural areas, in forest and in other localities like narrow streets where the space is limited
  • As replacement of bare conducts where reliability of supply is of prime importance
  • As replacement of bare lines where high degree of stability of supply voltage is of importance
  • In hilly terrains where cost of erection of overhead lines or under ground cable becomes very high
  • As reinforcement of existing system without increasing voltage
  • For temporary supplies
  • Reduces burning of transformers and maintenance

Advantages:

In comparison to bare overhead distribution lines, AB Cables have very high reliability during the services. As the power and neutral conductors are insulated with the best dielectric material, resulting in the following advantages:

  • Less fault rate on account of good protection against line and ground fault by high winds or falling trees or birds especially in hilly areas & forests as encountered in Rural distribution networks
  • High Insulation resistance to earth in all polluted atmosphere. Negligible currents and low losses
  • Multiple circuits of Power and Telephone Cables could be strung in the same set of poles or any other supports like walls etc
  • Better adaptability to run concurrently with existing over-head bare conductor system without any interference
  • High capacitance and low inductance leading to low impedance of lines
  • Lower voltage drop, higher current carrying capacities, vis-a-vis better Voltage Regulation
  • Longer spans and longer distance lines are possible with better systems stability
  • AB Cables are much safer then bare Conductors
  • It can be over hung in dense vegetation and forests
  • Additional connections can be easily and quickly made with hot-line connectors
  • Total lines costs are reduced
  • Maintenance costs are reduced
  • Very difficult to tap the AB cables, thus reducing theft which leads to lower distribution loses

 

 

Click and Ask for Price

 

ABC Cable Application:

The assembled insulated conductor shall be suitable for use in a system having a standard operating voltage not exceeding 600/1000V. The cores of an aerial bundled conductor shall be laid-up with a left-hand lay. The length of lay shall be 55-75 times the diameter of a phase conductor.

 

ABC Cable Construction:

The conductors shall be stranded circular and ,except where otherwise stated,shall comply with all the requirement for class 2 compacted stranded circular conductors of IEC60502.

1. Conductor: Aluminum conductor

2. Insulation: XLPE /PE

 

 

 

 

 

 

 

ABC Cable Specification:

(1)Self-supporting

Phase

Phase

Phase

AAC+UV-XLPE

Compact Conductor

UV-XLPE Insulation

No.X Normal Cross Section of Cores

No.of Al Wires

Overall Diameter

Normal Thickness

Min.

Diameter

No. X mm2

mm

mm

mm

mm

1 X 10

7

4.05

1.0

0.8

6.05

1 X 16

7

4.8

1.2

0.98

7.2

1 X 25

7

6

1.2

0.98

8.4

1 X 35

7

7.0

1.4

1.16

9.8

1 X 50

7

8.3

1.4

1.16

11.1

1 X 70

19

9.8

1.4

1.16

12.6

1 X 95

19

11.6

1.6

1.34

14.8

1 X 120

19

13

1.6

1.34

16.2

1 X 150

19

14.6

1.8

1.52

18.2

1 X 185

36

16.2

2.0

1.70

20.2

1 X 240

36

18.4

2.2

1.88

22.8

2 X 10

7

4.05

1.0

0.8

6.05

2 X 16

7

4.8

1.2

0.98

7.2

2 X 25

7

6

1.2

0.98

8.4

2 X 35

7

7.0

1.4

1.16

9.8

2 X 50

7

8.3

1.4

1.16

11.1

2 X 70

19

9.8

1.4

1.16

12.6

2 X 95

19

11.6

1.6

1.34

14.8

2 X 120

19

13

1.6

1.34

16.2

2 X 150

19

14.6

1.8

1.52

18.2

2 X 185

36

16.2

2.0

1.70

20.2

2 X 240

36

18.4

2.2

1.88

22.8

3 X 10

7

4.05

1.0

0.8

6.05

3 X 16

7

4.8

1.2

0.98

7.2

3 X 25

7

6

1.2

0.98

8.4

3 X 35

7

7.0

1.4

1.16

9.8

3 X 50

7

8.3

1.4

1.16

11.1

3 X 70

19

9.8

1.4

1.16

12.6

3 X 95

19

11.6

1.6

1.34

14.8

3 X 120

19

13

1.6

1.34

16.2

3 X 150

19

14.6

1.8

1.52

18.2

3 X 185

36

16.2

2.0

1.70

20.2

3 X 240

36

18.4

2.2

1.88

22.8

4 X 10

7

4.05

1.0

0.8

6.05

4 X 16

7

4.8

1.2

0.98

7.2

4 X 25

7

6

1.2

0.98

8.4

4 X 35

7

7.0

1.4

1.16

9.8

4 X 50

7

8.3

1.4

1.16

11.1

4 X 70

19

9.8

1.4

1.16

12.6

4 X 95

19

11.6

1.6

1.34

14.8

4 X 120

19

13

1.6

1.34

16.2

4 X 150

19

14.6

1.8

1.52

18.2

4 X 185

36

16.2

2.0

1.70

20.2

4 X 240

36

18.4

2.2

1.88

22.8

 

(2) Phase + Neutral

Phase Neutral Phase Neutral
AAC+UV-XLPE AAAC Compact Conductor  UV-XLPE Insulation  Conductor

No.X Normal Cross

 Section of Cores

No.X Normal Cross 

Section of Cores

No.of Al.Wire Overall Dia.

Normal 

Thickness

Min. No./Dia. of Al Alloy Wire
No. X mm2 No. X mm2 mm    mm Min. No./mm
1 X 16 1 X 16 7 4.8 1.2 0.98 7/1.70
1 X 25 1 X 25 7 6 1.2 0.98 7/2.10
1 X 35 1 X 35 7 7 1.4 1.16 7/2.50
1 X 50 1 X 50 7 8.3 1.4 1.16 7/3.00
1 X 70 1 X 70 19 9.8 1.4 1.16 7/3.50
1 X 95 1 X 95 19 11.6 1.6 1.34 19/2.50
1 X 120 1 X 120 19 13 1.6 1.34 19/2.80
1 X 150 1 X 150 19 14.6 1.8 1.52 37/2.25
1 X 185 1 X 185 36 16.2 2 1.7 37/2.50
1 X 240 1 X 240 36 18.4 2.2 1.88 61/2.25
2 X 16 1 X 16 7 4.8 1.2 0.98 7/1.70
2 X 25 1 X 25 7 6 1.2 0.98 7/2.10
2 X 35 1 X 35 7 7 1.4 1.16 7/2.50
2 X 50 1 X 50 7 8.3 1.4 1.16 7/3.00
2 X 70 1 X 70 19 9.8 1.4 1.16 7/3.50
2 X 95 1 X 95 19 11.6 1.6 1.34 19/2.50
2 X 120 1 X 120 19 13 1.6 1.34 19/2.80
2 X 150 1 X 150 19 14.6 1.8 1.52 37/2.25
2 X 185 1 X 185 36 16.2 2 1.7 37/2.50
2 X 240 1 X 240 36 18.4 2.2 1.88 61/2.25
3 X 16 1 X 16 7 4.8 1.2 0.98 7/1.70
3 X 25 1 X 25 7 6 1.2 0.98 7/2.10
3 X 35 1 X 35 7 7 1.4 1.16 7/2.50
3 X 50 1 X 50 7 8.3 1.4 1.16 7/3.00
3 X 70 1 X 70 19 9.8 1.4 1.16 7/3.50
3 X 95 1 X 95 19 11.6 1.6 1.34 19/2.50
3 X 120 1 X 120 19 13 1.6 1.34 19/2.80
3 X 150 1 X 150 19 14.6 1.8 1.52 37/2.25
3 X 185 1 X 185 36 16.2 2 1.7 37/2.50
3 X 240 1 X 240 36 18.4 2.2 1.88 61/2.25

ABC Cable sample: we can offer the sample free.  If possible we also can be support the clip for fitting, pls feel free to contact me.

 

Packaging & Shipping

Packaging & shipping

Packaging Detail: export wooden drum pack abc cable ,wooden iron drum and other export standard package

Delivery Detail: 10-15 days and also depend on the quantity

Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!

Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.

Sea freight:
FOB/C&F/CIF quotation are all available.

 

 

Contact Information

 

 

Any require contact me as follows:

Vivian Yuan | Sales Director
Zhengzhou Hongda Cable CO., LTD.

Email: sale04 @ zzhongdacable.com.cn

Skype ID: xinyuanyy
Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725

Tags: , ,

Contact us

 

 

 

Search