Brand Name: | Zi Wang |
Model Number: | YJV32 |
Insulation Material: | XLPE |
Type: | Low Voltage |
Application: | Underground |
Conductor Material: | Copper |
Jacket: | PVC |
Packaging Detail: | 250M/Reel, 500M/Reel, 1000M/Reel, or drum with seal; your requirement can be met, too! |
0.6/1kV 4 Core 35mm2 Armoured Cable Specifications
1. Application
The products can be produce according to the standard IEC 60502. Our factory can also design and manufacture special XLPE cable according to the other standards required by the customers’.
They not only have excellent electric conductivity mechanical properties, but also have powerful resistance against chemical corrosion, heating and environmental stress.
2. Technical Data for your reference
Section | Core | Cu Wire No./Diameter | XLPE Insulation Thick | PVC Beded | SWA Wire No./Diameter | PVC Outersheath |
mm2 | no. | no./mm | mm | mm | no./mm | mm |
16 | 4 | 7/1.7 | 0.7 | 1.2 | 38/1.6 | 1.8 |
25 | 4 | 7/2.14 | 0.9 | 1.2 | 42/1.6 | 1.8 |
35 | 4 | 7/2.52 | 0.9 | 1.2 | 46/1.6 | 1.9 |
4. 0.6/1KV 4 Core CU/ XLPE /SWA /PVC Power Cable (Steel wire armoured )
TECHNICAL SPECIFICATIONS |
|
1- Type of Cable |
Cu/XLPE/PVC/SWA/PVC |
2- Standard |
IEC 60502 |
3- Rated Voltage (U0 / U) (V) |
600/1000 |
4- Number of cores and nominal cross-section (N0xmm²) |
4×50 |
5- Material of Conductor |
Copper (Class 2) |
6- Current Carrying Capacity |
|
In air* (A) |
209 |
Underground** (A) |
177 |
7- DC Resistant of Conductor at 20°C (Ω/km) |
0.387 |
8- Max. Continous conductor temperature (°C) |
90 |
9- AC Resistance at Max. Operating Temperature (Ω/km) |
0.493 |
10- Power Loss at 20°C with Max. Operating Current (kW/km) |
105 |
11- Permesible Conductor Temperature at Short Circuit (°C) |
250 |
12- Max. Short Circuit Current for 1 s (kA) |
5.28 |
13- Material of Insulation |
XLPE |
14- Wall Thickness of Insulation (mm) |
1.0 |
15- Number and Diameter of Concentric Conductor (N0xmm) : |
– |
16- Size of Steel Armoured (mm) |
2.0 |
17- Material of Sheath |
PVC |
18- Wall Thickness of Sheath (mm) |
2.1 |
19- Aprox. Cable Diameter (mm) |
32.9 |
20- Aprox. Unit Weight of Cables (kg/km) |
3232 |
21- Aprox. Unit Weight of Steel (kg/km) |
1029.6 |
22- Aprox. Unit Weight of Conductor (kg/km) |
1661.5 |
23- Min. Bending Radius (mm) |
660 |
24- Min. Temperature of Laying (°C) |
-10°C |
* Ambient Temperature 30°C |
4 CORE ARMOURED ELECTRIC CABLE CERTIFICATES
4 CORE ARMOURED ELECTRIC CABLE PICTURE
4 CORE ARMOURED ELECTRIC CABLE PRODUCTION
4 CORE ARMOURED ELECTRIC CABLE PACKING: 250M/REEL, 500M/REEL, 1000M/REEL