0.6/1KV 35mm Low voltage ABC aerial twisted cable power cable for construction

0.6/1KV 35mm Low voltage ABC aerial twisted cable power cable for construction
Port: Qingdao
Payment Terms: L/C,D/P,T/T,Western Union,MoneyGram
Supply Ability: 2000 Kilometer/Kilometers per Month The capacity depending on AB cable size.
Place of Origin: Henan China
Brand Name: Hongda
Model Number: ABC Cable
Insulation Material: XLPE
Type: Low Voltage
Application: Overhead
Conductor Material: Aluminum
Jacket: PVC
Nominal Section Area: 16~240mm2
Standard: IEC228, IEC209, IEC60502, GB14049-93
Rated voltage: AC 0.6/1(1.2)KV
Insulation Color: Black
Certificate: ISO9001
Core: 2 Core, 2+1 Core, 3+1 Core
Operating temperature: Not more than 90 degree
Installation temperature: Not lower than below zero 20 degree
Short Circuit temperature: Not exceed 250 degree
Insulation: XLPE HDPE PE PVC
Packaging Detail: export wooden drum, wooden iron drum or other export standard package. We can also pack it according to your requirement

0.6/1KV 35mm Low voltage ABC aerial twisted cable power cable for construction

Aerial Bunched Cables
Aerial Bunched Cables are used in theft prone areas, or as a replacement of bare conductors in rural areas, forest, hilly terrains etc. These AB cables give highly reliable performance, good protection against line and ground fault and good adaptability. Manufactured from quality raw material, these cables are durable and are safe for different electrical environments. These functional cables are available in standard dimensions and can also be customized as per client's requirement.

 

 

Click and Ask for Price

 

Features

  • Hongda Cable make Aerial Bunched Cable (ABC) is a novel concept for Overhead Power Distribution System.
  • Hongda Cable make Aerial Bunched Cable are designed, manufactured & tested conforming to IS: 14255, IS: 7098 (P-I) & other international specifications like IEC, NFC etc.

 

Applications
ABC can conveniently be used:

  • In theft prone areas.
  • As replacement of bare conductors in rural areas, in forest and in other localities like narrow streets where the space is limited.
  • As replacement of bare conducts where reliability of supply is of prime importance.
  • As replacement of bare lines where high degree of stability of supply voltage is of importance.
  • In hilly terrains where cost of erection of overhead lines or under ground cable becomes very high.
  • As reinforcement of existing system without increasing voltage.
  • For temporary supplies.
  • Reduces burning of transformers and maintenance.

 

Advantages
In comparison to bare overhead distribution lines, AB Cables have very high reliability during the services. As the power and neutral conductors are insulated with the best dielectric material, resulting in the following advantages:

  • Less fault rate on account of good protection against line and ground fault by high winds or falling trees or birds especially in hilly areas & forests as encountered in Rural distribution networks.
  • High Insulation resistance to earth in all polluted atmosphere. Negligible currents and low losses.
  • Multiple circuits of Power and Telephone Cables could be strung in the same set of poles or any other supports like walls etc.
  • Better adaptability to run concurrently with existing over-head bare conductor system without any interference.
  • High capacitance and low inductance leading to low impedance of lines.
  • Lower voltage drop, higher current carrying capacities, vis-a-vis better Voltage Regulation.
  • Longer spans and longer distance lines are possible with better systems stability.
  • AB Cables are much safer then bare Conductors.
  • It can be over hung in dense vegetation and forests.
  • Additional connections can be easily and quickly made with hot-line connectors.
  • Total lines costs are reduced.
  • Maintenance costs are reduced.
  • Very difficult to tap the AB cables, thus reducing theft which leads to lower distribution loses.

Yes! I am Interested

 

Conductor Code name

Stranding and wire diameter

(no/mm)

Nominal overall diameter

(mm)

Cross-section area (mm2)

Approximate mass

(kg/km)

 

Breaking load

(kN)

Leo 7/2.50 7.5 34.4 94.3 5.71
Leonids 7/2.75 8.25 41.6 13 6.72
Libra 7/3.00 9 49.5 135 7.98
Mars 7/3.75 11.3 77.3 211 11.8
Mercury 7/4.50 13.5 111 304 16.9
Moon 7/4.75 14.3 124 339 18.9
Neptune 19/3.25 16.3 158 433 24.7
Orion 19/3.50 17.5 183 503 28.7
Pluto 19/3.75 18.8 210 576 31.9
Saturn 37/3.00 21 262 721 42.2
Sirius 37/3.25 22.8 307 845 48.2
Taurus 19/4.75 23.8 337 924 51.3
Triton 37/3.75 26.3 409 1120 62.2
Uranus 61/3.25 29.3 506 1400 75.2
Ursula 61/3.50 31.5 587 1620 87.3
Venus 61/3.75 33.8 673 1860 97.2

 

 

 

 

Any other information of Low voltage Aerail Bunded Cables pls contact with me:

Vivian Yuan | Sales Director
Zhengzhou Hongda Cable CO., LTD.
Landline: +86 371 6097 5616 | Fax: +86 371 6097 5616
Email: sale04atzzhongdacable.com.cn | Skype ID: xinyuanyy
Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725 
Address: Houzhai Industrial Park, Erqi Zone, Zhengzhou, China,450000

Tags: , ,

Contact us

 

 

 

Search