0.6/1 Kv Armor Power Cable 120mm 4 Core Armoured Cable Instrument Cable Steel Wire Armoured Cable Per Meter SWA/STA/AWA Power Ca

0.6/1 Kv Armor Power Cable 120mm 4 Core Armoured Cable Instrument Cable Steel Wire Armoured Cable Per Meter SWA/STA/AWA Power Ca
Port: Qingdao
Payment Terms: L/C
Supply Ability: 5000 Meter/Meters per Week
Place of Origin: Henan China
Brand Name: ZMS Cable/OEM
Model Number: YJV33
Insulation Material: XLPE
Type: Low Voltage
Application: Construction
Conductor Material: Copper
Jacket: PVC
Product Name: xlpe cable
Rated Voltage: 600/1000V (0.6/1kV)
Dimensions: 1.5,2.5,4,6,10,16,25,35,50,70,95,120,150,185,240,300,400mm2
No. of Cores: 1,2,3,4,5
Conductor: Stranded round compacted copper or aluminum conductor (Cu/Al)
Armoring Type: SWA, AWA, STA, DSTA, GSWA
Sheath: PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Voltage: 1kV~33kV
Operating Temperature: 0°C to 90°C
Standards: IEC60502-1, BS6346, BS5467, BS6360, BS6724, VDE0276, etc.
Packaging Detail: wooden-steel drums

 

 

Product Details

Number of Cores & Nominal Cross-section Area

Number of Cores

1

2

3

3+1

4

3+2

4+1

5

Section Area (mm2)

4 – 500

2.5 – 500

2.5 – 300

4 – 300

2.5 – 300

2.5 -300

4 – 300

2.5 – 95

 

More about 0.6/1kv power cable  style, Plz contact our team. We'll gvie reply ASAP.

 

 


0.6/1 KV cable , It to be used for indoors, in tunnel, in down wells,cable furrow or pipe, underground.
Note: the single core armored cables are used for D.C. system only. As for A.C. system, armor layer should be used of non-magnetic material or magnetic isolation measures.

 

 

Cable Structure:
1.  Conductor: Copper(Cu) or Aluminum
2.  PVC insulation
3.  Fill layer
4.  Around the package tape
5.  Inner Sheath
6.  Steel tape armor
7.  Outer Sheath
8.  Mark

Product Description:
–   PVC insulated PVC sheathed power cable (PVC/PVC Cable)
–   PVC insulated steel tape armored PVC sheathed power cable (PVC/STA/PVC Cable)
–   PVC insulated steel wire armored PVC sheathed power cable (PVC/SWA/PVC Cable)
–   Flame retardant PVC insulated PVC sheathed power cable (FR/PVC/PVC Cable)
–   Flame retardant PVC insulated steel tape armored PVC sheathed power cable (FR/PVC/STA/PVC Cable)
–   Flame retardant PVC insulated steel wire armored PVC sheathed power cable (FR/PVC/SWA/PVC Cable)

 

Application: 

1.steel-tape armored cable is to be laid underground, the cable could bear certain mechanical force.

2.Steel-wire cable is applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.

 

Standard: This product adopts the standards of IEC502 & IEC332-3

 

Scope of application: This item is applied for the alternating current circuitry with voltage (Uo/U) 0.6/1kV for the power supply.

 

Working conditions:

1)      This maximum working temperature of the conductor is 70°C.

2)      During having a short(lasting less than 5 seconds)the maximum temperature of the cable conductor for shall not be above 160°C.

3)      Environment temperature should be no lower than 0°C for laying the cable;

4)      Bending radius allowance of the cable;

single core cable: no steel tape cable 20D: steel tape cable 15D.

3 core cable: no steel tape cable 15D; steel tape cable 12D.

Notes: D practical external diameter of cable

Type, Description & Application of cable

Type

Description

Main application

VV

VLV

PVC insulation PVC sheath power cable

For laying in door, inducts and kin tunnels, but unable to bear pulling force and pressure.

VV22

VLV22

PVC insulated steel tape armored PVC sheathed power cable

For laying in doors, in tunnels and direct in ground, able to bear pulling force and pressure.

VV32

VLV32

PVC insulated fine steel wire armored PVC sheathed power cable

For laying down wells and under water, able to bear certain axis pulling force.

VV42

VLV42

PVC insulated steel wire armored PVC sheathed power cable

For laying down wells and under water, able to bear certain pulling force.

ZR-VV

ZR-VLV

PVC insulated PVC sheathed flame retardant power cable

For laying in door, inducts and in tunnels, but unable to bear pulling force and pressure.

ZR-VV22

ZR-VLV22

PVC insulated steel tape armored PVC sheathed flame retardant power cable

For laying in doors, in tunnels and directing ground, able to bear pulling force and pressure.

ZR-VV32

ZR-VLV32

PVC insulated fine steel wire armored PVC sheathed flame retardant power cable

For laying in doors, in wells, under water, able to bear certain pulling force.

ZR-VV42

ZR-VLV42

PVC insulated steel wire armored PVC sheathed flame retardant power cable

For laying down wells and under water, able to bear certain axis pulling force.

 

Core numbers & nominal cross-section area: see Table 2-2

Core No

1

2

3

3+1

4

3+2

4+1

5

Area

4~500

2.5~500

2.5~300

4~300

2.5~300

2.5~300

4~300

2.5~95

 

Main properties

No

Test item

Property

1

Construction

Listed to the tables

2

Conductor resistance

Listed to the tables

3

Voltage test

A.C 3.5kV 5min

No breaken

4

Mechanical properties before aging

Tensile strength

Insulation

Min.12.5N/mm²

Sheath

Min.12.5N/mm²

Elongation at break

Insulation

Min.150%

Sheath

Min.150%

Mechanical properties after aging

Tensile strength

Insulation

100°C±2°C 7days

Min.±12.5N/mm²

Sheath

100°C±2°C 7days

Min.±12.5N/mm²

Varying valve of tensile strength

Insulation

100°C±2°C 7days

Min.±25%

Sheath

100°C±2°C 7days

Min.±25%

Elongation at break

Insulation

100°C±2°C 7days

Min.±150%

Sheath

100°C±2°C 7days

Min.±150%

Varying valve of tensile strength

Insulation

100°C±2°C 7days

Min.±25%

Sheath

100°C±2°C 7days

Min.±25%

5

Flame-retardant property

Comply with GB12666.5-90(CB) and IEC332-3(CB)

6

Constant of insulation resistivity

Min at 20°C

36.7

Ki MΩ.km

Min at 70°C

0.037

 

0.6/1Kv PVC Insulated Steel Tape Armored PVC Sheathed Flame Retardant and Non-flame

 

Nom.cross sec.area of conductor(mm²)

Single quantity of Conductor

Insu.thickness(mm)

Steel tape thickness(mm)

Outer sheath thickness(mm)

Approx.dia of cable(mm)

Cable approx.weight(kg/km)

D.C. resistance

Test voltage(ac)

Cu

Al

20°CCu

20°CAl

Kv/5min

2×4

1

1.0

2×0.2

1.8

14.6

210

160

4.61

7.41

3.5

2×6

1

1.0

2×0.2

1.8

15.6

264

192

3.08

4.61

3.5

2×10

7

1.0

2×0.2

1.8

18.2

393

242

1.83

3.02

3.5

2×16

7

1.0

2×0.2

1.8

20.3

541

334

1.15

1.91

3.5

2×25

7

1.2

2×0.2

1.8

23.7

794

469

0.727

1.20

3.5

2×35

7

1.2

2×0.2

1.8

25.9

1037

585

0.524

0.868

3.5

2×50

19

1.4

2×0.2

1.8

22.6

1227

610

0.387

0.641

3.5

2×70

19

1.4

2×0.2

1.9

25.0

1650

747

0.268

0.443

3.5

2×95

19

1.6

2×0.5

2.1

30.2

2213

988

0.193

0.320

3.5

2×120

19

1.6

2×0.5

2.2

33.6

2733

1186

0.153

0.253

3.5

2×150

37

1.8

2×0.5

2.4

35.6

3396

1462

0.124

0.206

3.5

2×185

37

2.0

2×0.5

2.5

38.8

4112

1726

0.0991

0.164

3.5

 

 

Related Products

Related Products

 

ABC twist cable LV Copper Power Cable Bare Conductor ACSR
Aerial Bundled Cable with IEC60520 Standard 0.6/1kV overhead aerial bundled cable Low Voltage Armored Power Cable

 

 

Certifications

 

Production

 

Workshops

 

Our Services

1.Sufficient support for our tendering representatives.
2.OEM service available based on official & legal authorization.
3.Strict quality control system.
4.Faster lead time than our competitors.
5.Excellent quality with reasonable price.
6.Strong technical support (technical data, drawing, etc.)
7.Cable solutions to your particular requirements.
8.Free sample is available with economic express fee.
9.12 months quality guarantee after delivery.

 

 

 

FAQ
  1. Q: Is your company a factory or trading company?

    A: We are factory with our own trading company. Our trade business expands home and abroad.

  2. Q:When can I get the price?

    A:We usually quote within 12 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.

  3. Q:How can I get a sample to check your quality?

    A:After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.

  4. Q: What is Minimum Order Quantity?

    A: Generally, 1000 meters for building wire. For power cable, armored or unarmored, 500 meters.

  5. Q: Which standards for your products?

    A: We can produce wire and cable according to international standards: IEC, ASTM, BS, DIN, SANS, CSA or as customers’ requirement.

  6. Q: How about delivery time?

    A: If we have stock, delivery would be very quick. For the newly-produced products, 15 to 25 days for production.

  7. Q: Payment terms:

    A: Normally 30% paid as prepayment, balance paid before delivery. Or 100% L/C at sight.

  8. Q: What is your packing?

    A: Our electrical cable is using electrical cable wheel for the packing, the wheel can be all steel, steel frame and fumigated wood, or fumigated wooden cases. We are using different packing for different length of the cable, to ensure there will be no problem during the delivery of the products.

 

 

Tags: , ,

Contact us

 

 

 