<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ul power cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/ul-power-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Mon, 16 Sep 2019 02:32:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>Top quality Aluminum core XLPE Insulation PVC Sheath HT Power Cable,ul</title>
		<link>https://www.baoliyy.com/top-quality-aluminum-core-xlpe-insulation-pvc-sheath-ht-power-cableul/</link>
				<comments>https://www.baoliyy.com/top-quality-aluminum-core-xlpe-insulation-pvc-sheath-ht-power-cableul/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 02:32:10 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[ul power cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/top-quality-aluminum-core-xlpe-insulation-pvc-sheath-ht-power-cableul/</guid>
				<description><![CDATA[&#160;Top quality Aluminum core XLPE Insulation PVC Sheath HT Power Cable,ul&#160;&#160;&#160;&#160;&#160; &#160; Specification: &#160; 1. Top quality Aluminum core XLPE Insulation PVC Sheath HT Power Cable,ul2.cable manufacturer,ISO,EC3.free cable sample&#160;&#160;&#160; &#160; &#160; &#160; &#160; &#160; &#160; XLPE insulated power cable,0.6-35KV,producing under IEC,BS,ASTM,DIN standard and OEM basis. &#160; Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE Sheathed [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 18.0px"><strong>&nbsp;Top quality Aluminum core XLPE Insulation PVC Sheath HT Power Cable,ul<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></span></p>
<p><strong></strong>&nbsp;</p>
<p><span style="font-size: 18.0px">Specification:</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 16.0px">1. Top quality Aluminum core XLPE Insulation PVC Sheath HT Power Cable,ul<br />2.cable manufacturer,ISO,EC<br />3.free cable sample<br />&nbsp;&nbsp;&nbsp;</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><em></em>&nbsp;</p>
<p><em></em>&nbsp;</p>
<p>&nbsp;</p>
<p>XLPE insulated power cable,0.6-35KV,producing under IEC,BS,ASTM,DIN standard and OEM basis.</p>
<div>
<p>&nbsp;</p>
<p>Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE Sheathed Power Cable.</p>
<p>Executive Standard:</p>
<p>It is manufacture under GB/T12706-2002 standard(The same as IEC60502).</p>
<p><span style="font-size: 14.0px"><strong>Application:</strong></span></p>
<p>It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.</p>
<p>Using features:</p>
<p>1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.</p>
<p>2. No. of core: Single-core, Three-core.</p>
<p>3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250.</p>
<p>4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.</p>
<p>5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.</p>
<p>6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.</p>
<p>7. Working Frequency Voltage Test:.</p>
<p>For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. <br />For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture. <br />For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.</p>
<p>8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.</p>
<p>&nbsp;</p>
<p><strong><span style="font-size: 14.0px">This series includes:</span></strong></p>
<p>&nbsp;</p>
<p><span style="background-color: #ffff99">Copper (aluminum) core, XLPE insulated and sheathed power cables.</span></p>
<p><span style="background-color: #ffff99">Copper (aluminum) core, XLPE insulated, PE sheathed power cables.</span></p>
<p><span style="background-color: #ffff99">Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables.</span></p>
<p><span style="background-color: #ffff99">Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables.</span></p>
<p><span style="background-color: #ffff99">Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables.</span></p>
<p><span style="background-color: #ffff99">Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables</span></p>
<p><span style="background-color: #ffff99">Rated voltage: 0.6/1kV, 3.6/6kV.</span></p>
<p><span style="background-color: #ffff99">Number of cores: 1 to 6.</span></p>
<p><span style="background-color: #ffff99">Relative manufacturing standards: IEC60505, BS, DIN.</span></p>
<p><span style="background-color: #ffff99">&nbsp;</span></p>
<p><span style="background-color: #ffff99">Packing: Wooden drum, steel wooden drum.</span></p>
<p><span style="background-color: #ffff99">&nbsp;</span></p>
<p><span style="background-color: #ffff99">Power Cable</span></p>
<p><span style="background-color: #ffff99"><strong>-Conductor:&nbsp;</strong> </span><span style="background-color: #ffff99">Solid or stranded copper</span></p>
<p><span style="background-color: #ffff99"><strong>-Insulation:</strong> </span><span style="background-color: #ffff99">Cross-linked polyethylene( XLPE or PVC)</span></p>
<p><span style="background-color: #ffff99"><strong>-Circuit Identication:&nbsp;</strong> </span><span style="background-color: #ffff99">The insulation shall be red, black</span></p>
<p><strong><span style="background-color: #ffff99">-Filler: </span></strong><span style="background-color: #ffff99">Polypropylene lament with lapped binding tape</span></p>
<p><strong><span style="background-color: #ffff99">-Inner Sheath: </span></strong><span style="background-color: #ffff99">Polyvinyl chloride (Black)</span></p>
<p><span style="background-color: #ffff99"><strong>-Armor:</strong> </span><span style="background-color: #ffff99">Galvanized steel wire</span></p>
<p><strong><span style="background-color: #ffff99">-Core-covering: </span></strong><span style="background-color: #ffff99">Binding tape</span></p>
<p><strong><span style="background-color: #ffff99">-Outer Sheath: </span></strong><span style="background-color: #ffff99">Polyvinyl chloride (Black)</span></p>
<p><span style="background-color: #ffff99">-Application: </span><br /><span style="background-color: #ffff99">For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.</span></p>
<p><span style="background-color: #ffff99">-Standards / Testing Specications: </span><br /><span style="background-color: #ffff99">IEC 60502-1.</span></p>
<p><span style="background-color: #ffff99">Installation</span></p>
<p>This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed,so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.</p>
<p>1. The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.</p>
<p>Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.</p>
<p>2. Brief Construction:</p>
<p>Single core or multi-core</p>
<p>Copper or aluminium conductor</p>
<p>XLPE insulation</p>
<p>Copper tape or copper wire screen</p>
<p>Galvanized steel wire armored</p>