<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>UG AL\/CU XLPE Insulated &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/ug-al-cu-xlpe-insulated/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Thu, 05 Sep 2019 13:28:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>UG AL/CU XLPE Insulated LT cable</title>
		<link>https://www.baoliyy.com/ug-al-cu-xlpe-insulated-lt-cable/</link>
				<comments>https://www.baoliyy.com/ug-al-cu-xlpe-insulated-lt-cable/#respond</comments>
				<pubDate>Thu, 05 Sep 2019 13:28:35 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[LT cable]]></category>
		<category><![CDATA[UG AL\/CU XLPE Insulated]]></category>
		<category><![CDATA[UG AL\/CU XLPE Insulated LT cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/ug-al-cu-xlpe-insulated-lt-cable/</guid>
				<description><![CDATA[Our company is a professional manufacturer of &#160; &#160; &#160; UG AL/CU &#160;XLPE Insulated LT cable &#160; .We have the best R&#38;D, production, sales and service team and modern enterprise management organization &#160; Application: &#160;Suitable for use in power distribution lines or fixed installation &#160; &#160; Operating Characteristics: *Max.short-circuit temperature of conductor shall not exceed(5s [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>Our company is a professional manufacturer of &nbsp; &nbsp; &nbsp; UG AL/CU &nbsp;XLPE Insulated LT cable &nbsp; .We have the best R&amp;D, production, sales and service team and modern enterprise management organization</p>
<p>&nbsp;</p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 24.0px;color: #ff0000;font-size: 16.0px"><strong>Application:</strong></span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">&nbsp;Suitable for use in power distribution lines or fixed installation &nbsp;</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left">&nbsp;</p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 24.0px;color: #ff0000;font-size: 16.0px"><strong>Operating Characteristics:</strong></span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">*Max.short-circuit temperature of conductor shall not exceed(5s maximum duration):</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">Cross-section of conductor &le;300mm2&nbsp; 160</span><span style="font-size: 9.0pt">&deg;C</span><span style="line-height: 21.0px;font-size: 14.0px">;</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">Cross-section of conductor &gt; 300mm2&nbsp; 140&nbsp;<span style="line-height: 18.0px;font-size: 9.0pt">&deg;C</span>&nbsp;.</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">*The ambient temperature under installation of cable should not below 0&nbsp;<span style="line-height: 18.0px;font-size: 9.0pt">&deg;C</span>&nbsp;.</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">*The bending radius of cable should not less than 10 times of diameter of the cable.</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left">&nbsp;</p>
<p style="font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">(1).The long-time permissible operation temperature of conductor shall not be higher than 70</span><span style="line-height: 21.0px;font-size: 14.0px">&deg;C</span><span style="line-height: 21.0px;font-size: 14.0px">.</span><br /><span style="line-height: 21.0px;font-size: 14.0px">(2).Conductor maximum short circuit(not more than 5 seconds)temperature shall not be higher than 160&nbsp;&deg;C&nbsp;.</span><br /><span style="line-height: 21.0px;font-size: 14.0px">(3).The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0&nbsp;&deg;C&nbsp;.</span><br /><span style="line-height: 21.0px;font-size: 14.0px">(4).Perfect chemical stability,resistant against acids,alkalis,grease and organic solvents, and flame.</span><br /><span style="line-height: 21.0px;font-size: 14.0px">(5).Light weight,perfect bending properties,installed and maintained easily and conveniently.</span></p>
<p style="font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">We provide armoured type and non-armored type for the power cables above.</span></p>
<p style="font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">&nbsp;</span></p>
<p style="font-family: arial;line-height: 18.0px;text-align: left"><span style="color: #ff0000"><strong><span style="line-height: 21.0px;font-size: 14.0px">Operating conditon when cable laying</span></strong></span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;color: #ff0000;font-size: 14.0px">in Air</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">1.The single-core cables are paralled laid,the distance between the cable center is 2 times diameter of the csble for cross section&nbsp;of conductor &le; 185mm<sup>2</sup>&nbsp;and 90mm for cross section of conductor &ge;240mm<sup>2</sup>.</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">2.Ambient air temperature:40 &deg;C</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">3.Max.permissible continuous opesating temperature of conductor:70 &deg;C</span></p>
<p style="font-family: arial;line-height: 18.0px;text-align: left">&nbsp;</p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;color: #ff0000;font-size: 14.0px">Direct in ground</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">1.When the single-core cables are installed seperately,the distance between the cables center is 2 times diameter of the cable</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">2.Solid temperature :25&deg;C</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">3.Max.permissible continuous&nbsp;operating temperature of conductor:70 &deg;C</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">4.Solid thermal resistivity:10 &deg;Cm/w</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">5.Depth of laying:0.7m</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="color: #000000;font-family: arial;font-size: 12.0px;line-height: 18.0px;text-align: left" border="0">
<tbody>
<tr>
<td style="overflow: hidden" colspan="4">
<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;XLPE&nbsp;CABLE&nbsp;&#039;S&nbsp;TYPE&nbsp;AND&nbsp;MAIN&nbsp;APPLICATION</p>
</td>
</tr>
<tr>
<td style="overflow: hidden" colspan="2">
<p>TYPE&nbsp;</p>
</td>
<td style="overflow: hidden" rowspan="2">
<p>Description</p>
</td>
<td style="overflow: hidden" rowspan="2">
<p>Main&nbsp;Application</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>CU&nbsp;CORE&nbsp;</p>
</td>
<td style="overflow: hidden">
<p>AI&nbsp;CORE&nbsp;</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>YJV&nbsp;</p>
<p>&nbsp;or&nbsp;&nbsp;YJY</p>
</td>
<td style="overflow: hidden">
<p>YJLV</p>
<p>&nbsp;&nbsp;or&nbsp;&nbsp;YJLY</p>
</td>
<td style="overflow: hidden">
<p>XLPE&nbsp;insulated,&nbsp;</p>
<p>PVC&nbsp;or&nbsp;PE&nbsp;sheath&nbsp;power&nbsp;cable&nbsp;</p>
</td>
<td style="overflow: hidden">
<p>Apply&nbsp;for&nbsp;laying&nbsp;indoors,</p>
<p>&nbsp;in&nbsp;tunnels&nbsp;and&nbsp;cable&nbsp;trench.&nbsp;</p>
<p>Unable&nbsp;to&nbsp;bear&nbsp;external&nbsp;mechanical&nbsp;forces.&nbsp;</p>
<p>Single&nbsp;core&nbsp;cable&nbsp;in&nbsp;magnetic&nbsp;duct&nbsp;is&nbsp;not&nbsp;permissible.</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>YJV22</p>
<p>or&nbsp;YJY23</p>
</td>
<td style="overflow: hidden">
<p>YJLV22</p>
<p>or&nbsp;YJLY23</p>
</td>
<td style="overflow: hidden">
<p>XLPE&nbsp;insulated,&nbsp;</p>
<p>steel&nbsp;tape&nbsp;armoured,&nbsp; PVC&nbsp;or&nbsp;PE&nbsp;sheath&nbsp;power&nbsp;cable&nbsp;</p>
</td>
<td style="overflow: hidden">
<p>Apply&nbsp;for&nbsp;laying&nbsp;indoors,&nbsp;</p>
<p>in&nbsp;tunnels,&nbsp;cable&nbsp;trench&nbsp;and&nbsp;direct&nbsp;in&nbsp;ground.&nbsp;</p>
<p>Be&nbsp;able&nbsp;to&nbsp;bear&nbsp;external&nbsp;mechanical&nbsp;forces,</p>
<p>&nbsp;but&nbsp;unable&nbsp;to&nbsp;bear&nbsp;large&nbsp;pulling&nbsp;forces.</p>
<p>&nbsp;</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>YLV32</p>
<p>or&nbsp;YJV33</p>
</td>
<td style="overflow: hidden">
<p>YJLV&nbsp;&nbsp;</p>
<p>or&nbsp;YJLY&nbsp;33</p>
</td>
<td style="overflow: hidden">
<p>XLPE&nbsp;insulated&nbsp;</p>
<p>fine&nbsp;steel&nbsp;wire&nbsp;armoured,&nbsp; PVC&nbsp;or&nbsp;PE&nbsp;sheath&nbsp;power&nbsp;cable&nbsp;</p>
</td>
<td style="overflow: hidden">
<p>Apply&nbsp;for&nbsp;laying&nbsp;indoors,</p>
<p>&nbsp;in&nbsp;tunnels,&nbsp;cable&nbsp;trench&nbsp;and&nbsp;direct&nbsp;in&nbsp;ground.</p>
<p>&nbsp;Be&nbsp;able&nbsp;to&nbsp;bear&nbsp;external&nbsp;machanical&nbsp;force&nbsp;</p>
<p>and&nbsp;moderate&nbsp;pulling&nbsp;force&nbsp;</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>YJV42</p>
<p>or&nbsp;YJV43</p>
</td>
<td style="overflow: hidden">
<p>YJLV42</p>
<p>or&nbsp;YJLV43</p>
</td>
<td style="overflow: hidden">
<p>XLPE&nbsp;insulated,&nbsp;</p>
<p>thick&nbsp;steel&nbsp;wire&nbsp;armoured,&nbsp;</p>
<p>PVC&nbsp;or&nbsp;PE&nbsp;sheath&nbsp;power&nbsp;cable&nbsp;</p>
</td>
<td style="overflow: hidden">
<p>Apply&nbsp;for&nbsp;laying&nbsp;in&nbsp;water&nbsp;and&nbsp;seabed.</p>
<p>Be&nbsp;able&nbsp;to&nbsp;bear&nbsp;possitive&nbsp;pressure&nbsp;and&nbsp;pulling&nbsp;force&nbsp;</p>
</td>
</tr>
</tbody>
</table></div>
<p style="font-family: arial;line-height: 18.0px;text-align: left">&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-4sb4s" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4sb4s" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Hot sale products</span></div>
<div style="padding: 10.0px 0">
<div style="overflow:auto"><table style="border-collapse: collapse;background-color: #ffffff;width: 80.0%" border="1">
<tbody>
<tr style="height: 34.0px">
<td style="height: 34.0px;width: 18.6842%"><strong><span style="font-size: 14.0px">ABC&nbsp; cable&nbsp;</span></strong></td>
<td style="height: 34.0px;width: 34.3158%"><strong><span style="font-size: 14.0px">electrical wire&nbsp;</span></strong></td>
<td style="height: 34.0px;width: 41.0%"><strong><span style="font-size: 14.0px">power cable&nbsp;</span></strong></td>
</tr>
<tr style="height: 122.0px">
<td style="height: 122.0px;width: 18.6842%"></td>
<td style="height: 122.0px;width: 34.3158%"></td>
<td style="height: 122.0px;width: 41.0%"></td>
</tr>
<tr style="height: 37.0px">
<td style="height: 37.0px;width: 18.6842%"><span style="font-size: 14.0px"><strong>armored power cable&nbsp;</strong></span></td>
<td style="height: 37.0px;width: 34.3158%"><span style="font-size: 14.0px"><strong><span style="color: #333333;font-style: normal;background-color: #ffffff;float: none">Concentric&nbsp;</span>cable&nbsp;</strong></span></td>
<td style="height: 37.0px;width: 41.0%"><span style="font-size: 14.0px"><strong>control cable</strong></span></td>
</tr>
<tr style="height: 181.0px">
<td style="height: 181.0px;width: 18.6842%"></td>
<td style="height: 181.0px;width: 34.3158%"></td>
<td style="height: 181.0px;width: 41.0%">&nbsp;</td>
</tr>
</tbody>
</table></div>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-8gz4e" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-8gz4e" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Certifications</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/ug-al-cu-xlpe-insulated-lt-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>