<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SWA electro armored henan cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/swa-electro-armored-henan-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Thu, 05 Sep 2019 13:44:11 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>0.6/1KV VV22 copper conductor PVC Insulation SWA electro armored henan cable</title>
		<link>https://www.baoliyy.com/0-6-1kv-vv22-copper-conductor-pvc-insulation-swa-electro-armored-henan-cable/</link>
				<comments>https://www.baoliyy.com/0-6-1kv-vv22-copper-conductor-pvc-insulation-swa-electro-armored-henan-cable/#respond</comments>
				<pubDate>Thu, 05 Sep 2019 13:44:11 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[henan cable]]></category>
		<category><![CDATA[PVC insulation armored cable]]></category>
		<category><![CDATA[SWA electro armored henan cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/0-6-1kv-vv22-copper-conductor-pvc-insulation-swa-electro-armored-henan-cable/</guid>
				<description><![CDATA[electro armored cable &#160; 0.6/1KV VV22 copper conductor PVC Insulation/Sheath electric Power Cable with steel tape armor, Meets GB/IEC/DIN/ASTM/BS Standards &#160; XLPE Cable,XLPE&#160;Insulated,CU/ALconductor,PVC/PE sheath,armoured Power Cable &#160; 1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards as request. &#160; 2. Rated Voltage [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>electro armored cable</p>
<p>&nbsp;</p>
<p>0.6/1KV VV22 copper conductor PVC Insulation/Sheath electric Power Cable with steel tape armor, Meets GB/IEC/DIN/ASTM/BS Standards</p>
<p>&nbsp;</p>
<p><strong>XLPE Cable,XLPE&nbsp;Insulated,CU/ALconductor,PVC/PE sheath,armoured Power Cable</strong></p>
<p>&nbsp;</p>
<p>1. <strong>Standard of XLPE Cable</strong>:</p>
<p>According to GB12706( Equal to IEC60502)Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards as request.</p>
<p><strong>&nbsp;</strong></p>
<p><strong>2. Rated Voltage of XLPE Cable: 11KV; 12KV;&nbsp; 24KV; 36KV</strong></p>
<p><strong>&nbsp;</strong></p>
<p><strong>3. Construction of XLPE Cable:</strong></p>
<p>Conductor:Copper or Aluminum</p>
<p>Insulation:XLPE</p>
<p>Inner sheath:PVC or PE</p>
<p>Armoured:Galvanized steel tape,Galvanized steel wire</p>
<p>Outer Sheath:PVC or PE</p>
<p>NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.</p>
<p>Also can do according to the customer&#039;s request.</p>
<p><strong>&nbsp;</strong></p>
<p><strong>4. Characters of XLPE Cable:</strong></p>
<p align="left">a.Max&nbsp; Long-time operating temperature of XLPE insulated cable is 90&deg;C</p>
<p>b.Installing temperature of cable should not be less than 0&deg;C</p>
<p>c.Max short-circuit temperature is not exceed 250&deg;C,Not more than5 Sec.</p>
<p>d.Unable be laid without the limit of fall with enough mechanical pull,Single core cable can not be laid in iron tube or fixed by circled iron tools around cables</p>
<p>&nbsp;</p>
<p>5. <strong>Description &amp; </strong><strong>Application of XLPE Cable:</strong></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr align="middle">
<td colspan="2">
<p>TYPE</p>
</td>
<td>
<p>NAME</p>
</td>
<td>
<p>Main Application</p>
</td>
</tr>
<tr align="left">
<td align="middle">
<p>CU core</p>
</td>
<td align="middle">
<p>AL core</p>
</td>
<td>
<p>&nbsp;</p>
</td>
<td>
<p>&nbsp;</p>
</td>
</tr>
<tr align="left">
<td>
<p>YJV/YJY</p>
</td>
<td>
<p>YJLV/YJLY</p>
</td>
<td>
<p>XLPE insulated,PVC/PE sheathed power cable</p>
</td>
<td>
<p>For laying indoor ,tunnel,canal and underground.Unable to bear external mechanical forces,but bear the traction force during laid</p>
</td>
</tr>
<tr align="left">
<td>
<p>YJV22/YJV23</p>
</td>
<td>
<p>YJLV22/YJLV23</p>
</td>
<td>
<p>XLPE insulated,steel tape armored,PVC/PE sheathed power cable</p>
</td>
<td>
<p>For laying indoor ,tunnel,canal and underground.Able to bear external mechanical forces,but unable to bear large pulling force</p>
</td>
</tr>
<tr align="left">
<td>
<p>YJV32/YJV33</p>
</td>
<td>
<p>YJLV32/YJLV33</p>
</td>
<td>
<p>XLPE insulated,thin steel wire armored,PVC/PE sheathed power cable</p>
</td>
<td>
<p>For laying in shaft,water underground will large difference of level.Able to bear external mechanical forces and moderate pulling force</p>
</td>
</tr>
<tr align="left">
<td>
<p>YJV42/YJV43</p>
</td>
<td>
<p>YJLV42/YJLV43</p>
</td>
<td>
<p>XLPE insulated,thick steel wire armored,PVC/PE sheathed power cable</p>
</td>
<td>
<p>For laying in water and seabed.Able to bear positive pressure and pulling force</p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p><strong>6. Advantage:</strong></p>
<p>a. Excellent electric and mechanical characteristics</p>
<p>b. Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant</p>
<p>c. Simple in structure,Convenient to use</p>
<p>d. Reduce costs</p>
<p><strong>&nbsp;</strong></p>
<p><strong>Rated Voltage</strong><strong>,</strong><strong>Core Numbers &amp; Nominal Cross-section Area</strong><strong>:</strong></p>
<p><strong>&nbsp;</strong></p>
<div style="overflow:auto"><table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td rowspan="2">
<div style="overflow:auto"><table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr align="left">
<td>
<p>U<sub>0</sub>/U<sub>m</sub>(kv)</p>
</td>
</tr>
<tr align="left">
<td>
<p>&nbsp;</p>
</td>
</tr>
<tr align="left">
<td>
<p>No.of Core</p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
</td>
<td>
<p align="center">1st class</p>
</td>
<td>
<p align="center">0.6/1</p>
</td>
<td>
<p align="center">1.8/3</p>
</td>
<td>
<p align="center">3.6/6</p>
</td>
</tr>
<tr>
<td>
<p align="center">2nd class</p>
</td>
<td>
<p align="center">1/1</p>
</td>
<td>
<p align="center">3/3</p>
</td>
<td>
<p align="center">6/6</p>
</td>
</tr>
<tr>
<td>
<p align="center">1 Core</p>
</td>
<td>
<p align="center">Section</p>
<p align="center">area(mm2)</p>
</td>
<td>
<p align="center">1.5-800</p>
</td>
<td>
<p align="center">25-800</p>
</td>
<td>
<p align="center">25-800</p>
</td>
</tr>
<tr>
<td>
<p align="center">2 Core</p>
</td>
<td>
<p align="center">Section</p>
<p align="center">Area(mm2)</p>
</td>
<td>
<p align="center">1.5-185</p>
</td>
<td>
<p align="center">/</p>
</td>
<td>
<p align="center">&nbsp;/</p>
</td>
</tr>
<tr>
<td>
<p align="center">3 Core</p>
</td>
<td>
<p>Section</p>
<p>area(mm2)</p>
</td>
<td>
<p align="center">1.5-400</p>
</td>
<td>
<p align="center">25-400</p>
</td>
<td>
<p align="center">25-400</p>
</td>
</tr>
<tr>
<td>
<p align="center">4 Core</p>
</td>
<td>
<p align="center">Section</p>
<p align="center">Area(mm2)</p>
</td>
<td>
<p align="center">2.5-400</p>
</td>
<td>
<p align="center">25-400</p>
</td>
<td>
<p align="center">&nbsp;/</p>
</td>
</tr>
<tr>
<td>
<p align="center">5 Core</p>
</td>
<td>
<p>Section</p>
<p>area(mm2)</p>
</td>
<td>
<p align="center">2.5-400</p>
</td>
<td>
<p align="center">25-400</p>
</td>
<td>
<p>/</p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>NO. Of Cores</p>
<p>Rated voltage</p>
<p>Nominal thickness of insulation</p>
<p>Thickness of sheath</p>
<p>Diameter of conductor</p>
<p>Approx. Overall diameter</p>
<p>Max cable weight</p>
<p>Nominal cross sectional area of conductor etc.</p>
<p><strong>&nbsp;</strong></p>
<p><strong>All above can do as every different standards OR as your special request</strong></p>