<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Shielded Instrument Cable 1.5mm &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/shielded-instrument-cable-1-5mm/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Thu, 05 Sep 2019 13:44:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>Multi-Pair multi-core Shielded flame retardant SWA Instrument Cable 1.5mm 2.5mm</title>
		<link>https://www.baoliyy.com/multi-pair-multi-core-shielded-flame-retardant-swa-instrument-cable-1-5mm-2-5mm/</link>
				<comments>https://www.baoliyy.com/multi-pair-multi-core-shielded-flame-retardant-swa-instrument-cable-1-5mm-2-5mm/#respond</comments>
				<pubDate>Thu, 05 Sep 2019 13:44:52 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[Multi-Pair Instrument Cable 2.5mm]]></category>
		<category><![CDATA[Shielded Instrument Cable 1.5mm]]></category>
		<category><![CDATA[SWA Instrument Cable 1.5mm]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/multi-pair-multi-core-shielded-flame-retardant-swa-instrument-cable-1-5mm-2-5mm/</guid>
				<description><![CDATA[Multi-Pair multi-core Shielded flame retardant SWA Instrument Cable&#160; 1.5mm&#160; &#160;2.5mm&#160; &#160; Copper Conductor 4 x 2.5mm2 PVC Pair Instrument Signal Cable pvc insulated cable Standard of insulated cable: It is manufacture under GB/T12706-2002 standard(The same as IEC60502). &#160; UP TO 600/1000V PE INSULATION INSTRUMENTATION CABLE&#160;Generally to IEC Standard No.: BS 5308-1978&#160;Maximum working temperature 70&#176; C&#160;PE [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>Multi-Pair multi-core Shielded flame retardant SWA Instrument Cable&nbsp; 1.5mm&nbsp; &nbsp;2.5mm&nbsp;</p>
<p>&nbsp;</p>
<h2 style="margin: 0.0px;padding: 0.0px 0.0px 6.0px 0.0px">Copper Conductor 4 x 2.5mm2 PVC Pair Instrument Signal Cable</h2>
<p>pvc insulated cable</p>
<p>Standard of insulated cable: <br />It is manufacture under GB/T12706-2002 standard(The same as IEC60502).</p>
<p>&nbsp;</p>
<p>UP TO 600/1000V PE INSULATION INSTRUMENTATION CABLE&nbsp;<br />Generally to IEC Standard No.: BS 5308-1978&nbsp;<br />Maximum working temperature 70&deg; C&nbsp;<br />PE or PVC/Multi-pair/ Collectively screened/Unarmoured/PVC&nbsp;<br />PE or PVC/Multi-pair/ Individually &amp; Collectively screened/Unarmoured/PVC&nbsp;<br />PE or PVC/Multi-pair/ Collectively screened/Galvanized steel wire armoured/PVC&nbsp;<br />PE or PVC/Multi-pair/ Individually &amp; Collectively screened/ Galvanized steel wire armoured/PVC&nbsp;<br />PE or PVC/Multi-pair/ Collectively screened/Galvanized steel wire braiding/PVC&nbsp;<br />PE or PVC/Multi-pair/ Individually &amp; Collectively screened/ Galvanized steel wire braiding/PVC</p>
<p>&nbsp;</p>
<h5><span style="font-size: 14.0px;color: #008080">Instrument Cable Application:</span></h5>
<p style="font-size: small;margin: 10.0px" align="left">For use in installations designed to connect electrical instrumentation circuits and provide communication services in and around process plants. Suitable for direct burial applications.</p>
<h5>Specification of instrument cable:</h5>
<p style="font-size: small;margin: 10.0px" align="left"><strong> Instrument Cable Conductors:</strong></p>
<p style="font-size: small;margin: 10.0px" align="left">0.5mm &#8211; class 5 flexible copper</p>
<p style="font-size: small;margin: 10.0px" align="left">0.75mm &#8211; class 5 flexible copper</p>
<p style="font-size: small;margin: 10.0px" align="left">1.5mm &#8211; class 2 stranded copper</p>
<p style="font-size: small;margin: 10.0px" align="left"><strong>Insulation:</strong>&nbsp;PE (Polyethylene)</p>
<p style="font-size: small;margin: 10.0px" align="left"><strong>Screen:</strong>&nbsp;CAM (Collective Aluminium Mylar)</p>
<p style="font-size: small;margin: 10.0px" align="left"><strong>Bedding:</strong>&nbsp;PE (Polyethylene)</p>
<p style="font-size: small;margin: 10.0px" align="left"><strong>Armour:</strong>&nbsp;SWA</p>
<p style="font-size: small;margin: 10.0px" align="left"><strong>Outer Sheath:</strong>&nbsp;PVC (Polyvinyl-Chloride)</p>
<p style="font-size: small;margin: 10.0px" align="left"><strong>Voltage Rating:</strong>&nbsp;300/500volts</p>
<p style="font-size: small;margin: 10.0px" align="left"><strong>Temp. Rating:</strong>&nbsp;65 C</p>
<p style="line-height: 18.0px;padding: 0.0px;margin: 0.0px"><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">Flexible&nbsp; instrumentation multi-core cables about PVC insulated and twisted parallel cable</span></span></p>
<p style="line-height: 18.0px;padding: 0.0px;margin: 0.0px"><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">&nbsp;</span></span></p>
<p style="line-height: 18.0px;padding: 0.0px;margin: 0.0px"><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">&nbsp;</span></span></p>
<p style="line-height: 18.0px;padding: 0.0px;margin: 0.0px"><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">Standard: National Standard GB/T 5023; IEC60227</span></span></p>
<p style="line-height: 18.0px;padding: 0.0px;margin: 0.0px"><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">Rated Voltage: 300/300V;</span></span></p>
<p style="line-height: 18.0px;padding: 0.0px;margin: 0.0px"><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">&nbsp;</span></span><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">Construction: 1. annealed flexible copper conductor</span></span></p>
<p style="line-height: 18.0px;padding: 0.0px;margin: 0.0px"><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.PVC insulated&nbsp;</span></span></p>
<p style="line-height: 18.0px;padding: 0.0px;margin: 0.0px"><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">&nbsp;</span></span><span style="line-height: 28.0px;font-size: 14.0pt"><span style="line-height: 28.0px;color: #008000">Application: used for electric appliance, electric tool, electric instruments and lighting, automatic system&nbsp;</span></span></p>
<p>Application of insulated cable Instrument Cable : <br />It is used to transmit and distribute power on the power line of A. C. Rated voltage 0.6/1kV.</p>
<div style="overflow:auto"><table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr align="left">
<td colspan="12"><span style="color: #008080">XLPE insulated electric cable Instrument Cable 0.6/1kv</span></td>
</tr>
<tr align="left">
<td rowspan="3">norminalsectional area&nbsp;</td>
<td rowspan="3">insulati-on thicknes</td>
<td rowspan="3">sheath thickness(mm)</td>
<td colspan="2" rowspan="3">overal diameter of cable (mm)</td>
<td colspan="3" rowspan="2"><sup>D.C resistance of conductor(km)</sup></td>
<td colspan="4"><sup>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</sup><sup>&nbsp;current rating</sup></td>
</tr>
<tr align="left">
<td colspan="2">in air(A)</td>
<td colspan="2">direct in soil(A)</td>
</tr>
<tr align="left">
<td>cu</td>
<td colspan="2">Al</td>
<td>cu</td>
<td>Al</td>
<td>cu</td>
<td>Al</td>
</tr>
<tr align="left">
<td>1&times;1.5</td>
<td>0.7</td>
<td>1.5</td>
<td colspan="2">6</td>
<td>&lt;=12.1</td>
<td colspan="2">&lt;=12.1</td>
<td>30</td>
<td>25</td>
<td>45</td>
<td>35</td>
</tr>
<tr align="left">
<td>1&times;4</td>
<td>0.7</td>
<td>1.5</td>
<td colspan="2">7</td>
<td>&lt;=7.41</td>
<td colspan="2">&lt;=7.41</td>
<td>45</td>
<td>35</td>
<td>60</td>
<td>50</td>
</tr>
<tr align="left">
<td>1&times;6</td>
<td>0.7</td>
<td>1.5</td>
<td colspan="2">7</td>
<td>&lt;=3.08</td>
<td colspan="2">&lt;=4.61</td>
<td>55</td>
<td>45</td>
<td>70</td>
<td>55</td>
</tr>
<tr align="left">
<td>1&times;35</td>
<td>0.9</td>
<td>1.5</td>
<td colspan="2">12</td>
<td>&lt;=0.524</td>
<td colspan="2">&lt;=0.868</td>
<td>175</td>
<td>140</td>
<td>190</td>
<td>150</td>
</tr>
<tr align="left">
<td>1&times;50</td>
<td>1</td>
<td>1.5</td>
<td colspan="2">13</td>
<td>&lt;=0.387</td>
<td colspan="2">&lt;=0.641</td>
<td>210</td>
<td>170</td>
<td>225</td>
<td>180</td>
</tr>
<tr align="left">
<td>1&times;70</td>
<td>
<p>1</p>
<p>.1</p>
</td>
<td>1.5</td>
<td colspan="2">14</td>
<td>&lt;=0.268</td>
<td colspan="2">&lt;=0.443</td>
<td>270</td>
<td>215</td>
<td>280</td>
<td>225</td>
</tr>
<tr align="left">
<td>1&times;95</td>
<td>1.1</td>
<td>1.5</td>
<td colspan="2">16</td>
<td>&lt;=0.193</td>
<td colspan="2">&lt;=0.320</td>
<td>340</td>
<td>275</td>
<td>335</td>
<td>270</td>
</tr>
<tr align="left">
<td>1&times;120</td>
<td>1.2</td>
<td>1.5</td>
<td colspan="2">18</td>
<td>&lt;=0.153</td>
<td colspan="2">&lt;=0.253</td>
<td>400</td>
<td>320</td>
<td>380</td>
<td>305</td>
</tr>
<tr align="left">
<td>1&times;150</td>
<td>1.4</td>
<td>2</td>
<td colspan="2">21</td>
<td>&lt;=0.124</td>
<td colspan="2">&lt;=0.206</td>
<td>460</td>
<td>370</td>
<td>425</td>
<td>340</td>
</tr>
<tr align="left">
<td>1&times;185</td>
<td>1.6</td>
<td>2</td>
<td colspan="2">23</td>
<td>&lt;=0.0991</td>
<td colspan="2">&lt;=0.164</td>
<td>530</td>
<td>415</td>
<td>480</td>
<td>375</td>
</tr>
<tr align="left">
<td>1&times;240</td>
<td>1.7</td>
<td>2</td>
<td colspan="2">25</td>
<td>&lt;=0.0754</td>
<td colspan="2">&lt;=0.125</td>
<td>625</td>
<td>490</td>
<td>555</td>
<td>435</td>
</tr>
<tr align="left">
<td>&hellip;</td>
<td>&nbsp;</td>
<td>&nbsp;</td>
<td colspan="2">&nbsp;</td>
<td>&nbsp;</td>
<td colspan="2">&nbsp;</td>
<td>&nbsp;</td>
<td>&nbsp;</td>
<td>&nbsp;</td>
<td>&nbsp;</td>
</tr>
<tr align="left">
<td>3&times;1.5</td>
<td>0.7</td>
<td>1.5</td>
<td colspan="2">10</td>
<td>&lt;=12.1</td>
<td colspan="2">&lt;=12.1</td>
<td>25</td>
<td>25</td>
<td>30</td>
<td>30</td>
</tr>
<tr align="left">
<td>3&times;2.5</td>
<td>0.7</td>
<td>1.5</td>
<td colspan="2">11</td>
<td>&lt;=7.41</td>
<td colspan="2">&lt;=12.1</td>
<td>30</td>
<td>25</td>
<td>35</td>
<td>30</td>
</tr>
<tr align="left">
<td>3&times;4</td>
<td>0.7</td>
<td>1.5</td>
<td colspan="2">12</td>
<td>&lt;=4.61</td>
<td colspan="2">&lt;=7.41</td>
<td>40</td>
<td>30</td>
<td>50</td>
<td>40</td>
</tr>
<tr align="left">
<td>&hellip;</td>
<td>&nbsp;</td>
<td>&nbsp;</td>
<td colspan="2">&nbsp;</td>
<td>&nbsp;</td>
<td colspan="2">&nbsp;</td>
<td>&nbsp;</td>
<td colspan="2">&nbsp;</td>
<td>&nbsp;</td>
</tr>
<tr align="left">
<td colspan="12" rowspan="3">Attention: We can provide more info than above data, if needed.The above are just some examples.</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p><span style="color: #008080;font-size: 14.0px">Using features of insulated cable Instrument Cable : </span><br />1. Rated voltage: Uo/U: 0.6/1kV <br />2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor). <br />3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 160oC. <br />4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997. <br />5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.</p>
<p>Model: insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable</p>
<p>&nbsp;</p>
</p>
<p><span style="color: #008080;font-size: 16.0px">welcome to inquire us&nbsp; Instrument Cable</span></p>
<div id="ali-anchor-AliPostDhMb-f1jw8" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-f1jw8" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">contact information</span></div>
<div style="padding: 10.0px 0">
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: normal;background-color: #ffffff"><strong><span style="color: #0000ff;font-size: 16.0px">Contact information</span></strong></p>
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: normal;background-color: #ffffff"><span style="color: #0000ff;font-size: 16.0px">&nbsp;</span></p>
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: normal;background-color: #ffffff"><span style="color: #0000ff;font-size: 16.0px">Any needs or question ,please contact us ,we will be more pleasure to service you.</span></p>
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: normal;background-color: #ffffff">&nbsp;</p>
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: normal;background-color: #ffffff"><span style="color: #0000ff;font-size: 16.0px">We are looking forward to your inquiry and nice cooperaton.</span></p>
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: normal;background-color: #ffffff">&nbsp;</p>
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: normal;background-color: #ffffff">&nbsp;</p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/multi-pair-multi-core-shielded-flame-retardant-swa-instrument-cable-1-5mm-2-5mm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
