<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Rubber Insulated Multi Cores Control Cable Flat Cable for Elevator &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/rubber-insulated-multi-cores-control-cable-flat-cable-for-elevator/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Tue, 10 Sep 2019 07:56:02 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>Rubber Insulated Multi Cores Control Cable Flat Cable for Elevator</title>
		<link>https://www.baoliyy.com/rubber-insulated-multi-cores-control-cable-flat-cable-for-elevator/</link>
				<comments>https://www.baoliyy.com/rubber-insulated-multi-cores-control-cable-flat-cable-for-elevator/#respond</comments>
				<pubDate>Tue, 10 Sep 2019 07:56:02 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[Rubber Insulated Multi Cores Control Cable Flat Cable for Elevator]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/rubber-insulated-multi-cores-control-cable-flat-cable-for-elevator/</guid>
				<description><![CDATA[Application: Type Name Application Site KVV Copper conductor PVC insulated &#38; sheathed control cable Permanent installation indoors,in cable ditches or pipes KVVP Copper conductor PVC insulated &#38; sheathed copper wire braiding screened control cable Permanent installation indoors,in cable ditches or pipes where shielding is required KVVP2 Copper conductor PVC insulated &#38; sheathed,control cable with copperl [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="margin: 0.0px;color: #000000;background-color: #ffffff;text-align: left;padding: 0.0px"><strong>Application:</strong></p>
<div style="overflow:auto"><table style="text-align: left;background-color: #e8e811;margin: 0.0px;width: 100.0%;color: #000000;padding: 0.0px" border="0" cellspacing="1" cellpadding="0">
<tbody>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-weight: bold;font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Type</td>
<td style="font-weight: bold;font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Name</td>
<td style="font-weight: bold;font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Application Site</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">KVV</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor PVC insulated &amp; sheathed control cable</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Permanent installation indoors,in cable ditches or pipes</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">KVVP</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor PVC insulated &amp; sheathed copper wire braiding screened control cable</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Permanent installation indoors,in cable ditches or pipes where shielding is required</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">KVVP2</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor PVC insulated &amp; sheathed,control cable with copperl tape shield</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Permanent installation indoors,in cable ditches or pipes where shielding is required</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">KVV22</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor, PVC insulated &amp; sheathed,control cable with steel tape armmoured</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Permanent installation indoors,in cable ditches ,pipes or underground be able to bear stronger outer mechanical force</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">KVVR</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor, PVC insulated and sheathed flexible control cable</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Iinstallation indoors where flexibility and movability are required</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">KVVRP</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor, PVC insulated &amp; sheathed, braiding screened flexible control cable</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Iinstallation indoors where flexibility shielding and movability are required</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">ZR-KVV</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor PVC insulated &amp; sheathed,flame retardant control cable</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">For laying indoors, in trenched, in ducts and for fixed installation, the cable should be flame retardant</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">ZR-KVVP2</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor PVC insulated &amp; sheathed flame retardant control cable with steel tape shield</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">For laying indoors, in trenched, in ducts and for fixed installation, the cable should be flameretardant</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">ZR-KVV2</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor PVC insulated &amp; sheathed&nbsp; flame retardant control cable with steel tape armour</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">For laying indoors, in trenched, in ducts and underground, the cable should&nbsp; be flame&nbsp; retardant and able to bear beavier external mechanical force, and for fixed installation</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px">
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">ZR-KVVR</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">Copper conductor PVC insulated &amp; sheathed flame retardant flexible control cable</td>
<td style="font-size: 12.0px;margin: 0.0px;color: #333333;height: 24.0px;background-color: #ffffff;text-align: left;padding: 0.0px 0.0px 0.0px 14.0px">For laying indoors, and the cable should be flame retardant flexible and movable</td>
</tr>
</tbody>
</table></div>
<p style="margin: 0.0px;color: #000000;background-color: #ffffff;text-align: left;padding: 0.0px">The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.</p>
<p style="margin: 0.0px;color: #000000;background-color: #ffffff;text-align: left;padding: 0.0px"><strong>Standards:</strong></p>
<p style="margin: 0.0px;color: #000000;background-color: #ffffff;text-align: left;padding: 0.0px">The products can be produced according to the standard GB9330-1998,and the factory can also manufacture the cables in accordance with other standards.</p>
<p style="margin: 0.0px;color: #000000;background-color: #ffffff;text-align: left;padding: 0.0px">
<p style="margin: 0.0px;color: #000000;background-color: #ffffff;text-align: left;padding: 0.0px">
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/rubber-insulated-multi-cores-control-cable-flat-cable-for-elevator/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
