<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>NA2XS(F)2Y PE sheath Power Cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/na2xsf2y-pe-sheath-power-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Fri, 20 Mar 2020 01:00:26 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>NA2XS(F)2Y XLPE insulation PE sheath Power Cable</title>
		<link>https://www.baoliyy.com/na2xsf2y-xlpe-insulation-pe-sheath-power-cable/</link>
				<comments>https://www.baoliyy.com/na2xsf2y-xlpe-insulation-pe-sheath-power-cable/#respond</comments>
				<pubDate>Fri, 20 Mar 2020 01:00:26 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[NA2XS(F)2Y medium voltage cable]]></category>
		<category><![CDATA[NA2XS(F)2Y PE sheath Power Cable]]></category>
		<category><![CDATA[NA2XS(F)2Y XLPE insulation Power Cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/na2xsf2y-xlpe-insulation-pe-sheath-power-cable/</guid>
				<description><![CDATA[Key words: &#160; NA2XS(F)2Y XLPE insulation &#160;PE sheath Power Cable &#160; Constructions &#160; &#160; Conductor Compact Stranded Copper /Al Conductor, Class 2 as per IEC 60228 Circular solid Copper/AL &#160;Conductor, Class 1 as per IEC 60228 Flexible Stranded Copper/AL &#160;Conductor, Class 5 as per IEC 60228 Conductor Screen Semi-conductor (MV only) Insulation XLPE(Cross-linked polyethylene) Insulation [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p align="left"><span style="font-size: 16.0px">Key words: &nbsp; NA2XS(F)2Y XLPE insulation &nbsp;PE sheath Power Cable </span></p>
<p align="left">&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Constructions</span></strong></p>
<p align="left">&nbsp;</p>
<p align="left">&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 14.25pt" align="left">
<td style="width: 130.65pt;height: 14.25pt" rowspan="3">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Conductor</span></p>
</td>
<td style="width: 301.7pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Compact Stranded Copper /Al Conductor, Class 2 as per IEC 60228</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Circular solid Copper/AL &nbsp;Conductor, Class 1 as per IEC 60228</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Flexible Stranded Copper/AL &nbsp;Conductor, Class 5 as per IEC 60228</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Conductor Screen</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Semi-conductor (MV only)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Insulation</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">XLPE(Cross-linked polyethylene)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Insulation Screen </span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Semi-conductor (MV only)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Separate Screen </span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Copper Tape (MV must, LV optional)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Filler</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">PP Yarn, or Paper</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Wrapping Tape</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">PP</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Inner Covering</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Extruded PVC (MV only)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Armour</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Steel Wire, or Steel Tape, or Aluminium Tape optional</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Overall Sheath</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">PVC or PE</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Applications</span></strong></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.</span></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standards</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">International: IEC 60502-2, IEC 60228</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">China</span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: GB/T 12706.2-2008</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Other standards such as </span><span style="font-family: arial;color: #333333;font-size: 10.0pt">BS,DIN and ICEA upon request</span><strong></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Technical data</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Rated voltage: 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Maximum Conductor Temperature: under normal (90<span style="color: #333333">&deg;C</span>), emergency (130<span style="color: #333333">&deg;C</span>) or short circuit no more than 5 s (250<span style="color: #333333">&deg;C</span>) conditions.</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Min. Ambient Temp.</span><span style="font-family: arial;color: #333333;font-size: 10.0pt"> 0&deg;C, after installation and only when cable is in a fixed position</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 15 x cable O.D for single-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x cable O.D for multi-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 12 x cable O.D for multi-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">Certificates</span></strong></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">CE, RoHS, CCC, KEMA and more others at request</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt"><br />Specifications</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 33.0pt" align="left">
<td style="width: 36.8pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV</span></p>
</td>
<td style="width: 175.2pt;background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
<td style="width: 220.3pt;background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">XLPE Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Apply to shafts,water and soil,able to bear the larger positive pressure.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="height: 33.0pt" rowspan="2">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">For laying in shaft, water underground and large diference of level, able to bear external mechanical pressure and moderate pulling force.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-family: arial;font-size: 10.0pt">&nbsp;</span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/na2xsf2y-xlpe-insulation-pe-sheath-power-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>