	<title>NA2XSA2Y-S cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/na2xsa2y-s-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Mon, 16 Sep 2019 01:49:48 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>8.7/15 KV 18/30 KV Medium Voltage Aerial Power Distribution NA2XSA2Y-S Overhead Cable</title>
		<link>https://www.baoliyy.com/8-7-15-kv-18-30-kv-medium-voltage-aerial-power-distribution-na2xsa2y-s-overhead-cable/</link>
				<comments>https://www.baoliyy.com/8-7-15-kv-18-30-kv-medium-voltage-aerial-power-distribution-na2xsa2y-s-overhead-cable/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 01:49:48 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[Medium Voltage Aerial Power Distribution]]></category>
		<category><![CDATA[NA2XSA2Y-S cable]]></category>
		<category><![CDATA[Overhead cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/8-7-15-kv-18-30-kv-medium-voltage-aerial-power-distribution-na2xsa2y-s-overhead-cable/</guid>
				<description><![CDATA[&#160;8.7/15 KV 18/30 KV Medium Voltage Aerial Power Distribution NA2XSA2Y-S Overhead Cable Product Description &#160; STANDARDS International&#160;:&#160; IEC&#160;60228; IEC&#160;60332-1; IEC&#160;60502-2; IEC&#160;60811-1-1; IEC&#160;60811-1-2; IEC&#160;60811-1-3; IEC&#160;60811-2-1; IEC&#160;60811-3-1; IEC&#160;60811-4-1National&#160;:&#160; ASTM&#160;A&#160;475; NTP-IEC&#160;60228; NTP-IEC&#160;60502-2 DESCRIPTION &#160; Application Medium voltage aerial power distribution. Transformer feeders, power plants, industrial and operation installations,&#160;in places where underground networks cannot be possible,&#160;mining installations, tree-lined urban [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>&nbsp;8.7/15 KV 18/30 KV Medium Voltage Aerial Power Distribution NA2XSA2Y-S Overhead Cable</p>
<div id="ali-anchor-AliPostDhMb-02run" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-02run" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<div style="margin-bottom: 10.0px;color: #333333;font-family: arial , helvetica , sans-serif;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: 20.0px;background-color: #f3f3f3">
<h3 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em">STANDARDS</h3>
<p><strong>International&nbsp;:&nbsp;</strong> IEC&nbsp;60228; IEC&nbsp;60332-1; IEC&nbsp;60502-2; IEC&nbsp;60811-1-1; IEC&nbsp;60811-1-2; IEC&nbsp;60811-1-3; IEC&nbsp;60811-2-1; IEC&nbsp;60811-3-1; IEC&nbsp;60811-4-1<br /><strong>National&nbsp;:&nbsp;</strong> ASTM&nbsp;A&nbsp;475; NTP-IEC&nbsp;60228; NTP-IEC&nbsp;60502-2</div>
<h3 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;color: #333333;font-family: arial , helvetica , sans-serif;font-style: normal;line-height: 20.0px;background-color: #f3f3f3">DESCRIPTION</h3>
<div style="color: #333333;font-family: arial , helvetica , sans-serif;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: 20.0px;background-color: #f3f3f3">
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">&nbsp;</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><span style="color: #cc0000">Application</span></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">Medium voltage aerial power distribution. Transformer feeders, power plants, industrial and operation installations,&nbsp;in places where underground networks cannot be possible,&nbsp;mining installations, tree-lined urban zones or with little space.</p>
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">&nbsp;</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><span style="color: #cc0000">Construction</span></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">1. Conductor: Compact stranded aluminium, class 2.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">2. Inner semi-conductor: Extruded.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">3. Insulation: Cross linked polyethylene XLPE-TR (Tree retardant).</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">4. External semi-conductor: Extruded strippable.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">These last three components extruded CV (continuous vulcanization) triple extrusion.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">5. Screen: Aluminium tapes.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">6. Outer sheath: <span style="color: #333333;font-family: arial , helvetica , sans-serif;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: 20.0px;float: none;background-color: #f3f3f3">Polyethylene&nbsp;</span>PE.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">7. Messenger: Galvanized stranded steel wire.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">8. Sheath: Polyethylene PE.</p>
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">&nbsp;</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><span style="color: #cc0000">Main characteristics</span></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">Conductor temperature&nbsp;of&nbsp;90&ordm;C for normal operation, 130&deg;C for emergency overload and 250&deg;C for short circuit conditions.&nbsp;Good resistance to traction. Excellent properties against heat aging. Resistance to abrasion, sunlight, weather, ozone, acids, alkalis and other chemical substances at normal temperatures. Flame retardant.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>Gauge:</strong></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">From 35 mm<sup>2</sup> up to 185 mm<sup>2</sup>.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>Marking:</strong></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">INDECO S.A. NA2XSA2Y-S 8.7/15 kV &#8211; Nb. Coresx1xSection &#8211; Year.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>Packing:</strong></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">Non returnable wooden reels.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>Colour:</strong></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">Insulation: Natural (Core identification with binder tapes: green(R), white(S), red(T).</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">Outer sheath: Black.</p>
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">&nbsp;</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><span style="color: #cc0000">National standards</span></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>NTP-IEC 60228: </strong>Conductors of insulated cables.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>NTP-IEC 60502-2: </strong>Power cables with extruded insulation and their accessories for rated voltages from 6 kV up to 30 kV.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>ASTM A 475: </strong>Zinc coated steel wire strand.</p>
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">&nbsp;</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><span style="color: #cc0000">International standards</span></p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60228: </strong>Conductors of insulated cables.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60332-1: </strong>Test for vertical flame propagation for a single insulated wire or cable.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60502-2: </strong>Power cables with extruded insulation and their accessories for rated voltages from 6 kV up to 30 kV.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60811-1-1: </strong>Measurement of thickness and overall dimensions &#8211; Test&nbsp;for determining the mechanical properties.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60811-1-2: </strong>Thermal ageing methods.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60811-1-3: </strong>Water absorption tests &#8211; Shrinkage test.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60811-2-1: </strong>Ozone resistance, hot set and mineral oil immersion tests.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60811-3-1: </strong>Pressure test at high temperature &#8211; Tests for resistance to cracking.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em"><strong>IEC 60811-4-1: </strong>Resistance to environmental stress cracking &#8211; Measurement of the melt flow index &#8211; Carbon black and/or mineral filler content measurement in polyethylene by direct combustion.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">&nbsp;</p>
</div>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-xu8ex" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-xu8ex" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Drum Packing</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5eq22" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5eq22" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p><strong><span style="font-size: 16.0px">Production Line:</span></strong></p>
<p><strong><span style="font-size: 16.0px"></span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-size: 16.0px">&nbsp;</span></strong></p>
<p><strong><span style="font-size: 16.0px">Canton Fair:</span></strong></p>
<p><strong><span style="font-size: 16.0px"></span></strong></p>
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-zfaky" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-zfaky" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Certifications</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/8-7-15-kv-18-30-kv-medium-voltage-aerial-power-distribution-na2xsa2y-s-overhead-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>