<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IS 7098 Part -1 \/IS 1554 Part-1 &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/is-7098-part-1-is-1554-part-1/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Fri, 20 Mar 2020 01:15:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>Copper Cable with Armour,MV 2XFY 3c X 95 sq.mm</title>
		<link>https://www.baoliyy.com/copper-cable-with-armourmv-2xfy-3c-x-95-sq-mm/</link>
				<comments>https://www.baoliyy.com/copper-cable-with-armourmv-2xfy-3c-x-95-sq-mm/#respond</comments>
				<pubDate>Fri, 20 Mar 2020 01:15:33 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[2XFY]]></category>
		<category><![CDATA[IS 7098 Part -1 \/IS 1554 Part-1]]></category>
		<category><![CDATA[power cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/copper-cable-with-armourmv-2xfy-3c-x-95-sq-mm/</guid>
				<description><![CDATA[XLPE Cu armd 3*240 sq mm 2XFY MV power cable &#160;&#160; Applications Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>XLPE Cu armd 3*240 sq mm 2XFY MV power cable <br />&nbsp;&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Applications</span></strong></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.</span></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt"> <span style="font-family: arial;color: #231f20;font-size: 10.0pt"><br /></span> </span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standards</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">International: IEC 60502-2, IEC 60228</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">China</span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: GB/T 12706.2-2008</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Other standards such as </span><span style="font-family: arial;color: #333333;font-size: 10.0pt">BS,DIN and ICEA upon request</span><strong></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Technical data</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Rated voltage: 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Maximum Conductor Temperature: under normal (90<span style="color: #333333">&deg;C</span>), emergency (130<span style="color: #333333">&deg;C</span>) or short circuit no more than 5 s (250<span style="color: #333333">&deg;C</span>) conditions.</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Min. Ambient Temp.</span><span style="font-family: arial;color: #333333;font-size: 10.0pt"> 0&deg;C, after installation and only when cable is in a fixed position</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 15 x cable O.D for single-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x cable O.D for multi-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 12 x cable O.D for multi-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">Certificates</span></strong></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">CE, RoHS, CCC, KEMA and more others at request</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt"><br />Specifications</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 33.0pt" align="left">
<td style="width: 36.8pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV</span></p>
</td>
<td style="width: 175.2pt;background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
<td style="width: 220.3pt;background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">XLPE Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Apply to shafts,water and soil,able to bear the larger positive pressure.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="height: 33.0pt" rowspan="2">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">For laying in shaft, water underground and large diference of level, able to bear external mechanical pressure and moderate pulling force.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-family: arial;font-size: 10.0pt">&nbsp; <span style="font-family: arial;font-size: 10.0pt"></span> </span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/copper-cable-with-armourmv-2xfy-3c-x-95-sq-mm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>IS 7098 Part -1 /IS 1554 Part-1 PVC Cu armd 2XFY YWY LV MV power cables</title>
		<link>https://www.baoliyy.com/is-7098-part-1-is-1554-part-1-pvc-cu-armd-2xfy-ywy-lv-mv-power-cables/</link>
				<comments>https://www.baoliyy.com/is-7098-part-1-is-1554-part-1-pvc-cu-armd-2xfy-ywy-lv-mv-power-cables/#respond</comments>
				<pubDate>Fri, 20 Mar 2020 01:15:24 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[CU\/AL XLPE PVC cable 2XFY]]></category>
		<category><![CDATA[IS 7098 Part -1 \/IS 1554 Part-1]]></category>
		<category><![CDATA[power cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/is-7098-part-1-is-1554-part-1-pvc-cu-armd-2xfy-ywy-lv-mv-power-cables/</guid>
				<description><![CDATA[XLPE Cu armd 3*240 sq mm 2XFY MV power cable &#160;&#160; Applications Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>XLPE Cu armd 3*240 sq mm 2XFY MV power cable <br />&nbsp;&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Applications</span></strong></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.</span></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt"><span style="font-family: arial;color: #231f20;font-size: 10.0pt"><br /></span></span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standards</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">International: IEC 60502-2, IEC 60228</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">China</span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: GB/T 12706.2-2008</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Other standards such as </span><span style="font-family: arial;color: #333333;font-size: 10.0pt">BS,DIN and ICEA upon request</span><strong></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Technical data</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Rated voltage: 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Maximum Conductor Temperature: under normal (90<span style="color: #333333">&deg;C</span>), emergency (130<span style="color: #333333">&deg;C</span>) or short circuit no more than 5 s (250<span style="color: #333333">&deg;C</span>) conditions.</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Min. Ambient Temp.</span><span style="font-family: arial;color: #333333;font-size: 10.0pt"> 0&deg;C, after installation and only when cable is in a fixed position</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 15 x cable O.D for single-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x cable O.D for multi-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 12 x cable O.D for multi-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">Certificates</span></strong></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">CE, RoHS, CCC, KEMA and more others at request</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt"><br />Specifications</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 33.0pt" align="left">
<td style="width: 36.8pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV</span></p>
</td>
<td style="width: 175.2pt;background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
<td style="width: 220.3pt;background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">XLPE Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Apply to shafts,water and soil,able to bear the larger positive pressure.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="height: 33.0pt" rowspan="2">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">For laying in shaft, water underground and large diference of level, able to bear external mechanical pressure and moderate pulling force.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-family: arial;font-size: 10.0pt">&nbsp; <span style="font-family: arial;font-size: 10.0pt"></span> </span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/is-7098-part-1-is-1554-part-1-pvc-cu-armd-2xfy-ywy-lv-mv-power-cables/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>CU/AL XLPE PVC cable 2XFY MV 33 kv (E) cable IS 7098 Part -1 /IS 1554 Part-1</title>
		<link>https://www.baoliyy.com/cu-al-xlpe-pvc-cable-2xfy-mv-33-kv-e-cable-is-7098-part-1-is-1554-part-1/</link>
				<comments>https://www.baoliyy.com/cu-al-xlpe-pvc-cable-2xfy-mv-33-kv-e-cable-is-7098-part-1-is-1554-part-1/#respond</comments>
				<pubDate>Fri, 20 Mar 2020 01:12:28 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[2XFY]]></category>
		<category><![CDATA[IS 7098 Part -1 \/IS 1554 Part-1]]></category>
		<category><![CDATA[power cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/cu-al-xlpe-pvc-cable-2xfy-mv-33-kv-e-cable-is-7098-part-1-is-1554-part-1/</guid>
				<description><![CDATA[XLPE Cu armd 3*240 sq mm 2XFY MV power cable &#160;&#160; Applications Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>XLPE Cu armd 3*240 sq mm 2XFY MV power cable <br />&nbsp;&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Applications</span></strong></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.</span></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt"> <span style="font-family: arial;color: #231f20;font-size: 10.0pt"><br /></span> </span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standards</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">International: IEC 60502-2, IEC 60228</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">China</span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: GB/T 12706.2-2008</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Other standards such as </span><span style="font-family: arial;color: #333333;font-size: 10.0pt">BS,DIN and ICEA upon request</span><strong></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Technical data</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Rated voltage: 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Maximum Conductor Temperature: under normal (90<span style="color: #333333">&deg;C</span>), emergency (130<span style="color: #333333">&deg;C</span>) or short circuit no more than 5 s (250<span style="color: #333333">&deg;C</span>) conditions.</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Min. Ambient Temp.</span><span style="font-family: arial;color: #333333;font-size: 10.0pt"> 0&deg;C, after installation and only when cable is in a fixed position</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 15 x cable O.D for single-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x cable O.D for multi-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 12 x cable O.D for multi-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">Certificates</span></strong></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">CE, RoHS, CCC, KEMA and more others at request</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt"><br />Specifications</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 33.0pt" align="left">
<td style="width: 36.8pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV</span></p>
</td>
<td style="width: 175.2pt;background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
<td style="width: 220.3pt;background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">XLPE Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Apply to shafts,water and soil,able to bear the larger positive pressure.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="height: 33.0pt" rowspan="2">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">For laying in shaft, water underground and large diference of level, able to bear external mechanical pressure and moderate pulling force.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-family: arial;font-size: 10.0pt">&nbsp; <span style="font-family: arial;font-size: 10.0pt"></span> </span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/cu-al-xlpe-pvc-cable-2xfy-mv-33-kv-e-cable-is-7098-part-1-is-1554-part-1/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>IS 7098 Part -1 /IS 1554 Part-1 3core CU/AL XLPE PVC armoured cable 2XFY</title>
		<link>https://www.baoliyy.com/is-7098-part-1-is-1554-part-1-3core-cu-al-xlpe-pvc-armoured-cable-2xfy/</link>
				<comments>https://www.baoliyy.com/is-7098-part-1-is-1554-part-1-3core-cu-al-xlpe-pvc-armoured-cable-2xfy/#respond</comments>
				<pubDate>Fri, 20 Mar 2020 01:12:00 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[2XFY]]></category>
		<category><![CDATA[IS 7098 Part -1 \/IS 1554 Part-1]]></category>
		<category><![CDATA[power cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/?p=19518</guid>
				<description><![CDATA[XLPE Cu armd 3*240 sq mm 2XFY MV power cable &#160;&#160; Applications Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>XLPE Cu armd 3*240 sq mm 2XFY MV power cable <br />&nbsp;&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Applications</span></strong></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.</span></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt"> <span style="font-family: arial;color: #231f20;font-size: 10.0pt"><br /></span> </span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standards</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">International: IEC 60502-2, IEC 60228</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">China</span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: GB/T 12706.2-2008</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Other standards such as </span><span style="font-family: arial;color: #333333;font-size: 10.0pt">BS,DIN and ICEA upon request</span><strong></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Technical data</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Rated voltage: 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Maximum Conductor Temperature: under normal (90<span style="color: #333333">&deg;C</span>), emergency (130<span style="color: #333333">&deg;C</span>) or short circuit no more than 5 s (250<span style="color: #333333">&deg;C</span>) conditions.</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Min. Ambient Temp.</span><span style="font-family: arial;color: #333333;font-size: 10.0pt"> 0&deg;C, after installation and only when cable is in a fixed position</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 15 x cable O.D for single-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x cable O.D for multi-core non-armoured cables</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 12 x cable O.D for multi-core armoured cables</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">Certificates</span></strong></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">CE, RoHS, CCC, KEMA and more others at request</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt"><br />Specifications</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 33.0pt" align="left">
<td style="width: 36.8pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV</span></p>
</td>
<td style="width: 175.2pt;background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
<td style="width: 220.3pt;background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Conductor, XLPE Insulated, PE Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">XLPE Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Insulated,Steel Tape Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Apply to shafts,water and soil,able to bear the larger positive pressure.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Copper Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
<td style="height: 33.0pt" rowspan="2">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">For laying in shaft, water underground and large diference of level, able to bear external mechanical pressure and moderate pulling force.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al.Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-family: arial;font-size: 10.0pt">&nbsp; <span style="font-family: arial;font-size: 10.0pt"></span> </span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/is-7098-part-1-is-1554-part-1-3core-cu-al-xlpe-pvc-armoured-cable-2xfy/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
