<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>iec standard aaac &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/iec-standard-aaac/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Tue, 10 Sep 2019 08:05:59 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>Hot sale!!IEC standard AAAC electrical wire and cable</title>
		<link>https://www.baoliyy.com/hot-saleiec-standard-aaac-electrical-wire-and-cable/</link>
				<comments>https://www.baoliyy.com/hot-saleiec-standard-aaac-electrical-wire-and-cable/#respond</comments>
				<pubDate>Tue, 10 Sep 2019 08:05:59 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[AAAC]]></category>
		<category><![CDATA[electrical wire and cable]]></category>
		<category><![CDATA[iec standard aaac]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/hot-saleiec-standard-aaac-electrical-wire-and-cable/</guid>
				<description><![CDATA[&#160;Specifications IEC standard AAAC &#160;electrical wire and cable IEC standard AAAC &#160;electrical wire and cable &#160; has been widely used in power transmission lines with various voltage levels. &#160; 1. &#160; Applications IEC standard AAAC &#160;electrical wire and cable &#160;has&#160;been widely used in power transmission lines with various voltage levels,because they have such good characteristics [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>&nbsp;Specifications</h2>
<div style="clear: both">IEC standard AAAC &nbsp;electrical wire and cable</div>
<div style="clear: both">IEC standard AAAC &nbsp;electrical wire and cable &nbsp; has been widely used in power transmission lines with various voltage levels. </p>
</div>
<div style="clear: both">&nbsp;</div>
<div>
<p><span style="color: #33cccc"><strong>1. &nbsp; Applications</strong></span></p>
<p><span style="line-height: normal"> IEC standard AAAC &nbsp;electrical wire and cable &nbsp;</span><span style="line-height: normal">has&nbsp;</span>been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.</p>
<p>&nbsp;</p>
<p><span style="color: #33cccc"><strong>2. &nbsp;Service Performance</strong></span></p>
<p><span style="color: #000000"><strong>&nbsp; &nbsp; IEC standard AAAC &nbsp;electrical wire and cable </strong></span></p>
<p>(1).The permissible long-time operating temperature for aerial conductor is 70<sup>o</sup>C.</p>
<p>(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.</p>
<p>(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.</p>
<p>(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.</p>
<p>&nbsp;</p>
<p><span style="color: #33cccc"><strong>3. &nbsp; Product Performance</strong></span></p>
<p>&nbsp; &nbsp; &nbsp; IEC standard AAAC &nbsp;electrical wire and cable</p>
<p>(1).The electrical performance of AAC and ACSR is indicated in DC&Omega;/km(20<sup>o</sup>C).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 n&Omega;. m of international standard value.</p>
<p>(2).The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.</p>
<p>(3).The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.</p>
<p>a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.</p>
<p>b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.</p>
<p>&nbsp;</p>
<p><span style="color: #33cccc"><strong>4. &nbsp; Material Standard</strong></span></p>
<p>&nbsp; &nbsp; &nbsp;IEC standard AAAC &nbsp;electrical wire and cable</p>
<p>(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).</p>
<p>(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.</p>
<p>(3).Production can be arranged according to customers requirements for material standard,etc.</p>
<p>Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced</p>
<p>&nbsp;</p>
<p><span style="color: #33cccc"><strong>5. &nbsp; Chinese Standard</strong></span></p>
<p>&nbsp;&nbsp; &nbsp;IEC standard AAAC &nbsp;electrical wire and cable</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p>New Type</p>
</td>
<td>
<p>Original Type</p>
</td>
<td>
<p>Name</p>
</td>
<td>
<p>Range of Sectional Area</p>
</td>
</tr>
<tr>
<td>
<p>JL</p>
</td>
<td>
<p>LJ</p>
</td>
<td>
<p>All Aluminum Conductor</p>
</td>
<td>
<p>10-1500</p>
</td>
</tr>
<tr>
<td>
<p>JL/G1A JL/G1B JL/G2A JL/G2B JL/G3A</p>
</td>
<td>
<p>LGJ</p>
</td>
<td>
<p>Aluminum Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JL/G1AF JL/G2AF JL/G3AF</p>
</td>
<td>
<p>LGJF</p>
</td>
<td>
<p>Corrosion-Resistant Aluminum Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA1&nbsp; JLHA2</p>
</td>
<td>
<p>LHAJ</p>
</td>
<td>
<p>All Aluminum Alloy Conductor</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA1/G1A JLHA1/G1B JLHA1/G3A JLHA2/G1A JLHA2/G1B JLHA1/G3A</p>
</td>
<td>
<p>LHAGJ</p>
</td>
<td>
<p>Aluminum Alloy Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1120</p>
</td>
</tr>
<tr>
<td>
<p>JL/LHA1&nbsp; JL/LHA2</p>
</td>
<td>
<p>LLHAGJ</p>
</td>
<td>
<p>Aluminum Conductor Aluminum Alloy Reinforced</p>
</td>
<td>
<p>16-1400</p>
</td>
</tr>
<tr>
<td>
<p>JL/LB1A</p>
</td>
<td>
<p>LLBGJ</p>
</td>
<td>
<p>Aluminum Conductor Steel Coated Aluminum Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA2/LB1A JLHA1/LB1A</p>
</td>
<td>
<p>LHALBGJ</p>
</td>
<td>
<p>Aluminum Alloy Conductor Aluminum Coated Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JG1A JG1B JG2A JG3A</p>
</td>
<td>
<p>GJ</p>
</td>
<td>
<p>All Steel Stranded Conductor</p>
</td>
<td>
<p>6-63(27.1mm<sup>2</sup>-427mm<sup>2</sup>)</p>
</td>
</tr>
<tr>
<td>
<p>JLB1A JLB1B&nbsp; JLB2</p>
</td>
<td>
<p>LBGJ</p>
</td>
<td>
<p>Aluminum Coated Steel Conductor</p>
</td>
<td>
<p>4-200(12mm<sup>2</sup>-600mm<sup>2</sup></p>
</td>
</tr>
</tbody>
</table></div>
</div>
<p>&nbsp;</p>
</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/hot-saleiec-standard-aaac-electrical-wire-and-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>high quality IEC standard AAAC cable wire for power transmission</title>
		<link>https://www.baoliyy.com/high-quality-iec-standard-aaac-cable-wire-for-power-transmission/</link>
				<comments>https://www.baoliyy.com/high-quality-iec-standard-aaac-cable-wire-for-power-transmission/#respond</comments>
				<pubDate>Tue, 10 Sep 2019 08:05:32 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[AAAC cable wire]]></category>
		<category><![CDATA[AAAC cable wire for power transmission]]></category>
		<category><![CDATA[iec standard aaac]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/high-quality-iec-standard-aaac-cable-wire-for-power-transmission/</guid>
				<description><![CDATA[&#160;Specifications &#160;&#160; IEC standard AAAC cable wire for power transmission &#160;&#160;IEC standard AAAC cable wire for power transmission&#160;has been widely used in power transmission lines with various voltage levels. &#160; 1.&#160;&#160;&#160;&#160;&#160;&#160; Applications &#160;&#160;&#160;IEC standard AAAC cable wire for power transmission&#160;has&#160;been widely used in power transmission lines with various voltage levels,because they have such good characteristics [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>&nbsp;Specifications</h2>
<div style="clear: both">&nbsp;&nbsp; IEC standard AAAC cable wire for power transmission</div>
<div style="clear: both"><span style="line-height: normal">&nbsp;</span><span style="line-height: normal">&nbsp;IEC standard AAAC cable wire for power transmission&nbsp;</span>has been widely used in power transmission lines with various voltage levels. </p>
</div>
<div style="clear: both">&nbsp;</div>
<div>
<p>1.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Applications</p>
<p><span style="line-height: normal">&nbsp;</span><span style="line-height: normal">&nbsp;</span><span style="line-height: normal">&nbsp;IEC standard AAAC cable wire for power transmission&nbsp;</span><span style="line-height: normal">has&nbsp;</span>been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.</p>
<p>2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Service Performance</p>
<p>(1).The permissible long-time operating temperature for aerial conductor is 70<sup>o</sup>C.</p>
<p>(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.</p>
<p>(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.</p>
<p>(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.</p>
<p>3.Product Performance</p>
<p>(1).The electrical performance of AAC and ACSR is indicated in DC&Omega;/km(20<sup>o</sup>C).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 n&Omega;. m of international standard value.</p>
<p>(2).The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.</p>
<p>(3).The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.</p>
<p>a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.</p>
<p>b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.</p>
<p>4.Material Standard</p>
<p>(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).</p>
<p>(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.</p>
<p>(3).Production can be arranged according to customers requirements for material standard,etc.</p>
<p>Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced</p>
<p>5.Chinese Standard</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p>New Type</p>
</td>
<td>
<p>Original Type</p>
</td>
<td>
<p>Name</p>
</td>
<td>
<p>Range of Sectional Area</p>
</td>
</tr>
<tr>
<td>
<p>JL</p>
</td>
<td>
<p>LJ</p>
</td>
<td>
<p>All Aluminum Conductor</p>
</td>
<td>
<p>10-1500</p>
</td>
</tr>
<tr>
<td>
<p>JL/G1A JL/G1B JL/G2A JL/G2B JL/G3A</p>
</td>
<td>
<p>LGJ</p>
</td>
<td>
<p>Aluminum Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JL/G1AF JL/G2AF JL/G3AF</p>
</td>
<td>
<p>LGJF</p>
</td>
<td>
<p>Corrosion-Resistant Aluminum Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA1&nbsp; JLHA2</p>
</td>
<td>
<p>LHAJ</p>
</td>
<td>
<p>All Aluminum Alloy Conductor</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA1/G1A JLHA1/G1B JLHA1/G3A JLHA2/G1A JLHA2/G1B JLHA1/G3A</p>
</td>
<td>
<p>LHAGJ</p>
</td>
<td>
<p>Aluminum Alloy Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1120</p>
</td>
</tr>
<tr>
<td>
<p>JL/LHA1&nbsp; JL/LHA2</p>
</td>
<td>
<p>LLHAGJ</p>
</td>
<td>
<p>Aluminum Conductor Aluminum Alloy Reinforced</p>
</td>
<td>
<p>16-1400</p>
</td>
</tr>
<tr>
<td>
<p>JL/LB1A</p>
</td>
<td>
<p>LLBGJ</p>
</td>
<td>
<p>Aluminum Conductor Steel Coated Aluminum Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA2/LB1A JLHA1/LB1A</p>
</td>
<td>
<p>LHALBGJ</p>
</td>
<td>
<p>Aluminum Alloy Conductor Aluminum Coated Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JG1A JG1B JG2A JG3A</p>
</td>
<td>
<p>GJ</p>
</td>
<td>
<p>All Steel Stranded Conductor</p>
</td>
<td>
<p>6-63(27.1mm<sup>2</sup>-427mm<sup>2</sup>)</p>
</td>
</tr>
<tr>
<td>
<p>JLB1A JLB1B&nbsp; JLB2</p>
</td>
<td>
<p>LBGJ</p>
</td>
<td>
<p>Aluminum Coated Steel Conductor</p>
</td>
<td>
<p>4-200(12mm<sup>2</sup>-600mm<sup>2</sup></p>
</td>
</tr>
</tbody>
</table></div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/high-quality-iec-standard-aaac-cable-wire-for-power-transmission/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
