<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>H05V-K cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/h05v-k-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Mon, 16 Sep 2019 01:39:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>H05V-K PVC Cable</title>
		<link>https://www.baoliyy.com/h05v-k-pvc-cable/</link>
				<comments>https://www.baoliyy.com/h05v-k-pvc-cable/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 01:39:43 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[3 core pvc cable]]></category>
		<category><![CDATA[H05V-K cable]]></category>
		<category><![CDATA[PVC cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/h05v-k-pvc-cable/</guid>
				<description><![CDATA[Product Description Specification: &#160; Name:&#160;H05V-K PVC Cable Conductor Type: Class 5 Insulation: PVC Rated Voltage:300/300V, 300/500V, 450/750V &#160; &#160; 1. Application:Fixed wiring, civil power, mobile equipment &#160; 2. Rated Voltage: &#160; &#160;450/750V more than 1.5mm2&#160;single core conductor &#160; &#160;300/500V less than 1.5mm2&#160;single core and multi-core conductor &#160; &#160;300/300V less than&#160;1.5mm2&#160;multi-core conductor &#160; 3. Test Voltage: [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<div id="ali-anchor-AliPostDhMb-joulo" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-joulo" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><strong><span style="font-size: 16.0px;font-family: times new roman , times">Specification:</span></strong></p>
<p>&nbsp;</p>
<p>Name:&nbsp;H05V-K PVC Cable</p>
<p><span style="font-size: 14.0px">Conductor Type: Class 5</span></p>
<p><span style="font-size: 14.0px">Insulation: PVC</span></p>
<p><span style="font-size: 14.0px">Rated Voltage:300/300V, 300/500V, 450/750V</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 14.0px"><strong><span style="font-size: 16.0px"><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">1. Application:</span></span></strong><span style="font-family: arial , sans-serif">Fixed wiring, civil power, mobile equipment</span></span></p>
<p>&nbsp;</p>
<p><span style="font-size: 16.0px"><strong><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">2. Rated Voltage: </span></strong></span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;450/750V more than 1.5mm<sup>2&nbsp;</sup>single core conductor</span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;300/500V less than 1.5mm<sup>2&nbsp;</sup>single core and multi-core conductor</span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;300/300V less than&nbsp;1.5mm<sup>2</sup>&nbsp;multi-core conductor</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 16.0px"><strong><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">3. Test Voltage: </span></strong></span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;AC 1500/5Min for 0.5~1mm<sup>2&nbsp;</sup>multi-core conductor</span></p>
<p><span style="font-size: 14.0px"><span style="font-family: arial , sans-serif">&nbsp; &nbsp;AC 2000/5Min for 0.5~1mm<sup>2</sup>&nbsp;single core and multi-core conductor</span><span style="font-family: arial , sans-serif;color: #333333"><br /></span><span style="font-family: arial , sans-serif">&nbsp; &nbsp;AC 2500/5Min other</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-size: 16.0px"><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">4. Color of Insulation:</span></span></strong></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;Red, Yellow, Black, White, Green, Light Blue, Grey, Brown, Violet, Orange, Yellow/Green</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 14.0px"><span style="font-size: 16.0px"><strong><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">5. Manufactured Standards:</span></strong></span><span style="font-family: arial , sans-serif"> IEC 60227-2007,&nbsp; <span style="font-size: 15.555556px;line-height: 23.333334px">VDE 0295 etc.</span></span></span></p>
<p><span style="font-size: 14.0px"><span style="font-family: arial , sans-serif"><br /> </span></span></p>
<p><span style="font-size: 16.0px"><strong><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">6. Conductor type: </span></strong></span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;IEC 60228-2004 class1, class2, class 5 and 6</span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;Nominal Cross-section area: 0.12~400mm<sup>2</sup></span></p>
<p>&nbsp;</p>
<p><span style="font-size: 16.0px"><strong><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">7. Notes:</span></strong></span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;1) Ambient temperature for insulation shall not be lower than 0<sup>o</sup>C.&nbsp;</span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;2) At nominal conditions, the conductor operating temperature is -15<sup>o</sup>C to +70<sup>o</sup>C</span></p>
<p><span style="font-family: arial , sans-serif;font-size: 14.0px">&nbsp; &nbsp;3) Fire resistant wire conform to IEC 60331-2009, Flame resistant wire conform to IEC 60332-2004</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="width: 743.0px;height: 831.0px" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Type</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Name</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Laying Site and Requirements</span></p>
</td>
<td align="left">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Long-time Permissible Working Temperature of Conductor(&deg;C)</span></p>
</td>
</tr>
<tr align="left">
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">227IEC01/05 BV BLV</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Copper Conductor, PVC Insulated Wire</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Fixed laid in the circumstance of indoor, conduit etc.</span></p>
</td>
<td rowspan="2">
<p style="text-align: center"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">70</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Aluminum Conductor, PVC Insulated Wire</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">227IEC 07 BV-90</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Heat Resistant Copper Conductor, PVC Insulated Wire at 90</span></p>
<p align="left"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">&nbsp;</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Fixed laid in the circumstance of high temperature environment and can be laid indoor, conduit etc.</span></p>
<p align="left"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">&nbsp;</span></p>
</td>
<td>
<p style="text-align: center"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">90</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">BVR</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Copper Conductor, PVC Insulated Flexible Wire</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Fixed laid where flexibility is required.</span></p>
</td>
<td>
<p style="text-align: center"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">70</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">227-IEC10 BVV</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Copper Conductor PVC Insulated and PVC Sheathed Round Wire</span></p>
</td>
<td rowspan="4">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Fixed laid where high mechanical protection and moisture are required. They can be laid in the air or underground.</span></p>
</td>
<td rowspan="4">
<p style="text-align: center"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">70</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">BLVV</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Aluminum Conductor PVC Insulated and PVC Sheathed Round Wire</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">BVVB</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Copper Conductor PVC Insulated and PVC Sheathed Flat Wire</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">BLVVB</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Aluminum Conductor PVC Insulated and PVC Sheathed Flat Wire</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">227IEC 02 RV227 IEC 06 RV</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Copper Conductor, PVC Insulated Flexible Connector</span></p>
</td>
<td rowspan="4">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Mainly used at middle-light type movable equipments, instrument and meters, household appliances, power and lighting and the places where flexibility is required.</span></p>
</td>
<td rowspan="4">
<p style="text-align: center"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">70</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">227IEC 42 RVB</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Copper Conductor, PVC Insulated Flat Flexible Connector</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">RVS</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Copper Conductor, PVC Insulated Flexible Twisting Connector</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">227IEC52 RVV 227IEC53 RVV</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Copper Conductor PVC Insulated and PVC Sheathed Round Flexible Connector(Light and Common Type)</span></p>
</td>
</tr>
</tbody>
</table></div>
<p align="left"><span style="font-style: normal;font-weight: normal;font-size: 10.0pt;line-height: normal;font-family: arial , sans-serif;color: #333333">&nbsp;</span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-wetby" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wetby" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Certifications</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-15a13" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-15a13" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Production Equipment</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-gjbuy" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-gjbuy" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Test Equipment</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-9gvr4" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-9gvr4" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/h05v-k-pvc-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>