<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Flexible Multi-corecable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/flexible-multi-corecable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Mon, 20 Jun 2022 08:10:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>CE Certificated Mechanical System Control Cable Flexible Multi-core Copper Cable</title>
		<link>https://www.baoliyy.com/ce-certificated-mechanical-system-control-cable-flexible-multi-core-copper-cable/</link>
				<comments>https://www.baoliyy.com/ce-certificated-mechanical-system-control-cable-flexible-multi-core-copper-cable/#respond</comments>
				<pubDate>Mon, 20 Jun 2022 08:10:35 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[vericable]]></category>
		<category><![CDATA[control cable]]></category>
		<category><![CDATA[copper cable]]></category>
		<category><![CDATA[Flexible Multi-corecable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/ce-certificated-mechanical-system-control-cable-flexible-multi-core-copper-cable/</guid>
				<description><![CDATA[CE Certificated Mechanical System Control Cable Flexible Multi-core Copper Cable &#160; Application &#160; Control cable are used&#160;as&#160;power&#160;and&#160;connecting&#160;cables&#160;in&#160;mechanical&#160;engineering&#160; for&#160;tooling&#160;machinery,&#160;control&#160;unit,&#160;production&#160;lines,&#160;transportation&#160;equipment,&#160;conveyor&#160;and&#160;assembly&#160;lines&#160;as&#160;well&#160;as&#160;in&#160;plant&#160;construction&#160;under&#160;the&#160;circumstance&#160;that&#160;the&#160;rated&#160;voltage&#160;is&#160;up&#160;to&#160;450/750V&#160;AC. &#160; Specifications Flexible control cables as per standard VDE 0250,which includes: YY cable (YSLY)&#160; Versatile unscreened or unshielded cable suitable for most situations where there is only light mechanical stress CY cable (YSLCY) Multicore screened flexible cable [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="margin: 0.0px;font-size: 12.0px;font-weight: normal;line-height: inherit;padding: 0.0px;border: 0.0px;font-style: normal;font-family: arial , helvetica;vertical-align: baseline;color: #333333"><span style="font-size: 24.0px">CE Certificated Mechanical System Control Cable Flexible Multi-core Copper Cable</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 16.0px"><strong>Application</strong></span></p>
<p><span style="font-size: 14.0px">&nbsp;</span></p>
<p><span style="font-size: 14.0px">Control cable are used&nbsp;as&nbsp;power&nbsp;and&nbsp;connecting&nbsp;cables&nbsp;in&nbsp;mechanical&nbsp;engineering&nbsp;</span></p>
<p><span style="font-size: 14.0px">for&nbsp;tooling&nbsp;machinery,&nbsp;</span><span style="font-size: 14.0px">control&nbsp;unit,&nbsp;</span><span style="font-size: 14.0px">production&nbsp;lines,&nbsp;transportation&nbsp;equipment,&nbsp;conveyor&nbsp;and&nbsp;assembly&nbsp;lines&nbsp;as&nbsp;well&nbsp;as&nbsp;in&nbsp;plant&nbsp;construction&nbsp;</span><span style="font-size: 14.0px">under&nbsp;the&nbsp;circumstance&nbsp;that&nbsp;the&nbsp;rated&nbsp;voltage&nbsp;is&nbsp;up&nbsp;to&nbsp;450/750V&nbsp;AC.</span></p>
<p><span style="font-size: 14.0px">&nbsp;</span></p>
<p><span style="font-size: 16.0px"><strong>Specifications</strong></span></p>
<p><span style="font-size: 16.0px"><strong>Flexible control cables as per standard VDE 0250,which includes:</strong></span></p>
<div style="overflow:auto"><table style="margin: 0.0px;padding: 0.0px;font-style: normal;font-weight: 400;line-height: inherit;font-family: arial , sans-serif;font-size: 12.0px;vertical-align: baseline;width: 677.0px;background-color: #e1e1e1;color: #333333;border: 1.0px solid black;border-collapse: collapse;height: 250.0px" border="0">
<tbody>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;font-weight: inherit;line-height: inherit;font-size: 12.0px;vertical-align: baseline;background-color: #f4f4f4">
<td style="width: 86.0px">YY cable (YSLY)&nbsp;</td>
<td style="width: 584.4px">Versatile unscreened or unshielded cable suitable for most situations where there is only light mechanical stress</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;font-weight: inherit;line-height: inherit;font-size: 12.0px;vertical-align: baseline;background-color: #e1e1e1">
<td style="width: 86.0px">CY cable (YSLCY)</td>
<td style="width: 584.4px">Multicore screened flexible cable with Polyethylene Terephthalate (PETP) for electromagnetic interference free-transmission</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;font-weight: inherit;line-height: inherit;font-size: 12.0px;vertical-align: baseline;background-color: #f4f4f4">
<td style="width: 86.0px">SY cable (YSLYSY)</td>
<td style="width: 584.4px">Flexible shielded cable with galvanised steel wire braid for additional mechanical protection</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;font-weight: inherit;line-height: inherit;font-size: 12.0px;vertical-align: baseline;background-color: #e1e1e1">
<td style="width: 86.0px">LiYCY cable</td>
<td style="width: 584.4px">Screened and shielded cable for applications where moderate mechanical stress and electromagnetic screening is required</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;font-weight: inherit;line-height: inherit;font-size: 12.0px;vertical-align: baseline;background-color: #f4f4f4">
<td style="width: 86.0px">LiYY cable</td>
<td style="width: 584.4px">Unscreened and unshielded cable for light duty in dry and humid environments</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;font-weight: inherit;line-height: inherit;font-size: 12.0px;vertical-align: baseline;background-color: #e1e1e1">
<td style="width: 86.0px">LiHH cable</td>
<td style="width: 584.4px">Unscreened LSZH low capacitance control</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;font-weight: inherit;line-height: inherit;font-size: 12.0px;vertical-align: baseline;background-color: #f4f4f4">
<td style="width: 86.0px">LiHCH cable</td>
<td style="width: 584.4px">Screened LSZH data transmission cable</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px">&nbsp;</span></p>
<p><span style="font-size: 14.0px">1.&nbsp;Long-term&nbsp;service&nbsp;temperature&nbsp;of&nbsp;the&nbsp;cable&nbsp;conductor:&nbsp;70&nbsp;0C</span></p>
<p><span style="font-size: 14.0px">2.&nbsp;Rated&nbsp;voltage:&nbsp;450/750V</span></p>
<p><span style="font-size: 14.0px">3.&nbsp;Cable&nbsp;lying&nbsp;temperature&nbsp;&ge;0&nbsp;0C</span></p>
<p><span style="font-size: 14.0px">4.&nbsp;Cores:&nbsp;2,&nbsp;3,&nbsp;4,&nbsp;5,&nbsp;6,7,&nbsp;8,&nbsp;10,&nbsp;12,&nbsp;14,&nbsp;16,&nbsp;19,&nbsp;24,&nbsp;27,&nbsp;30,&nbsp;37,&nbsp;44,&nbsp;48,&nbsp;52,&nbsp;61</span></p>
<p><span style="font-size: 14.0px">5.&nbsp;Minimun&nbsp;bending&nbsp;radius:</span></p>
<p><span style="font-size: 14.0px">Non&nbsp;armored&nbsp;&ge;&nbsp;out&nbsp;diameter&nbsp;of&nbsp;cable&nbsp;6&nbsp;times</span></p>
<p><span style="font-size: 14.0px">Armored&nbsp;layer&nbsp;or&nbsp;copper&nbsp;tape&nbsp;shielded&nbsp;&ge;&nbsp;outer&nbsp;diameter&nbsp;of&nbsp;cable&nbsp;12&nbsp;times</span></p>
<p><span style="font-size: 14.0px">Shielded&nbsp;layer&nbsp;soft&nbsp;cable&nbsp;&ge;&nbsp;outer&nbsp;diameter&nbsp;of&nbsp;cable&nbsp;6&nbsp;times</span></p>
<p><span style="font-size: 14.0px">&nbsp;</span></p>
<p><span style="font-size: 14.0px">Note:We also produce flame-retardant control cable, low smoke halogen free flame-retardant control cable etc.</span></p>
<p><span style="font-size: 14.0px">&nbsp;</span></p>
<p><strong><span style="font-size: 16.0px">Construction and Types of control cable ZMS could supply</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">Type</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">Name</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">Application Site</span></p>
</td>
</tr>
<tr>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-16</span></p>
</td>
<td rowspan="3">
<p><span style="font-size: 14.0px">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-14</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">10</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-10</span></p>
</td>
</tr>
<tr>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-61</span></p>
</td>
<td rowspan="3">
<p><span style="font-size: 14.0px">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-14</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">10</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-10</span></p>
</td>
</tr>
<tr>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-10</span></p>
</td>
<td rowspan="3">
<p><span style="font-size: 14.0px">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">7-61</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">10</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-10</span></p>
</td>
</tr>
<tr>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">7-61</span></p>
</td>
<td rowspan="3">
<p><span style="font-size: 14.0px">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-14</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">10</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-14</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-61</span></p>
</td>
<td>
<p><span style="font-size: 14.0px">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr>
<td rowspan="2">
<p align="center"><span style="font-size: 14.0px">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-61</span></p>
</td>
<td rowspan="2">
<p><span style="font-size: 14.0px">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-48</span></p>
</td>
</tr>
<tr>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-16</span></p>
</td>
<td rowspan="3">
<p><span style="font-size: 14.0px">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-14</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">10</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-10</span></p>
</td>
</tr>
<tr>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-61</span></p>
</td>
<td rowspan="3">
<p><span style="font-size: 14.0px">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-14</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">10</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">2-10</span></p>
</td>
</tr>
<tr>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">7-61</span></p>
</td>
<td rowspan="3">
<p><span style="font-size: 14.0px">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-14</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">10</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-10</span></p>
</td>
</tr>
<tr>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">7-61</span></p>
</td>
<td rowspan="3">
<p><span style="font-size: 14.0px">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-14</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">10</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-10</span></p>
</td>
</tr>
<tr>
<td>
<p align="center"><span style="font-size: 14.0px">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-61</span></p>
</td>
<td>
<p><span style="font-size: 14.0px">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr>
<td rowspan="2">
<p align="center"><span style="font-size: 14.0px">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-size: 14.0px">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-size: 14.0px">4-61</span></p>
</td>
<td rowspan="2">
<p><span style="font-size: 14.0px">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
</tbody>
</table></div>
<p style="text-align: center">&nbsp;</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pm8cl" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pm8cl" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Detailed Images</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-t4bu4" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-t4bu4" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<h1>Related Products</h1>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="border-collapse: collapse;background-color: #ffffff;width: 80.0%;border: solid 2.0px #000000" border="2">
<tbody>
<tr style="height: 240.156px">
<td style="border: 2.0px solid #000000;height: 240.156px"></td>
<td style="border: 2.0px solid #000000;height: 240.156px"></td>
<td style="border: 2.0px solid #000000;height: 240.156px"></td>
</tr>
<tr style="height: 15.0px">
<td style="border: 2.0px solid #000000;text-align: center;height: 15.0px">33kv armored types of underground cables</td>
<td style="border: 2.0px solid #000000;height: 15.0px;text-align: center">AWA12/20kV single core underground cable</td>
<td style="border: 2.0px solid #000000;height: 15.0px;text-align: center">Medium voltage 3 core cables 70mm</td>
</tr>
<tr style="height: 15.0px">
<td style="border: 2.0px solid #000000;height: 15.0px"></td>
<td style="border: 2.0px solid #000000;height: 15.0px"></td>
<td style="border: 2.0px solid #000000;height: 15.0px"></td>
</tr>
<tr style="height: 15.0px">
<td style="border: 2.0px solid #000000;height: 15.0px;text-align: center">Factory price high quality ZMS supply PVC insulation PVC sheath 3 core armoured copper electric cables</td>
<td style="border: 2.0px solid #000000;height: 15.0px;text-align: center">Overhead transmission line aac aaac acsr conductor 35mm aluminum abc power cable</td>
<td style="border: 2.0px solid #000000;height: 15.0px;text-align: center">Overhead line conductor AAC AAAC ACSR fast cables price list</td>
</tr>
</tbody>
</table></div>
</div>
</div>
<div id="J-rich-text-description" style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;font-size: 12.0px;line-height: 15.0px;vertical-align: baseline;overflow: hidden;width: 750.0px;color: #333333">&nbsp;</div>
<div id="ali-anchor-AliPostDhMb-tm56t" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-tm56t" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Overviews</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<p><span style="color: #ffffff">&nbsp;</span></p>
<div id="ali-anchor-AliPostDhMb-pl8nw" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pl8nw" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Certifications</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-c6o9v" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-c6o9v" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<h1>FAQ</h1>
<ul>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Is your company a factory or trading company?</dt>
<dd>A: We are factory with our own trading company. Our trade business expands home and abroad.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: When can I get the price?</dt>
<dd>A:We usually quote within 12 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: How can I get a sample to check your quality?</dt>
<dd>A: After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: What is Minimum Order Quantity?</dt>
<dd>A: Generally, 1000 meters for building wire. For power cable, armored or unarmored, 500 meters.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Which standards for your products?</dt>
<dd>A: We can produce wire and cable according to international standards: IEC, ASTM, BS, DIN, SANS, CSA or as customers&rsquo; requirement.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: How about delivery time?</dt>
<dd>A: If we have stock, delivery would be very quick. For the newly-produced products, 15 to 25 days for production.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Payment terms:</dt>
<dd>A: Normally 30% paid as prepayment, balance paid before delivery. Or 100% L/C at sight</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: What is your packing?</dt>
<dd>A: Our electrical cable is using electrical cable wheel for the packing, the wheel can be all steel, steel frame and fumigated wood, or fumigated wooden cases. We are using different packing for different length of the cable, to ensure there will be no problem during the delivery of the products.</dd>
</dl>
</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/ce-certificated-mechanical-system-control-cable-flexible-multi-core-copper-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
