<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>flexible control cables for elevators &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/flexible-control-cables-for-elevators/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Tue, 10 Sep 2019 07:43:44 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>flexible control cables for elevators</title>
		<link>https://www.baoliyy.com/flexible-control-cables-for-elevators/</link>
				<comments>https://www.baoliyy.com/flexible-control-cables-for-elevators/#respond</comments>
				<pubDate>Tue, 10 Sep 2019 07:43:44 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[control cable]]></category>
		<category><![CDATA[flexible control cables for elevators]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/flexible-control-cables-for-elevators/</guid>
				<description><![CDATA[1.Control Cable products can be produced according to the standard GB/T9330-2008, Control Cables are suitable for the connection of controlling electrical equipment and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC. &#160; 2. Service Conditions(1)The long-time working [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 14.0px">1.Control Cable products can be produced according to the standard GB/T9330-2008, Control Cables are suitable for the connection of controlling electrical equipment and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.</span></p>
<p>&nbsp;</p>
<p style="text-align: left"><strong><span style="font-size: 14.0px">2. Service Conditions</span></strong><br /><span style="font-size: 14.0px">(1)The long-time working temperature of conductor of PVC insulated cable is 70&deg;C</span><br /><span style="font-size: 14.0px">(2)The temperature for laying the cables can&rsquo;t be lower than 0&deg;C.Permissible bending radius</span><br /><span style="font-size: 14.0px">(3) unarmoured cable: r &ge;6D;(D: outer diameter of the cable); armoured or copper-tape screened cable: r&ge;12D;shielded flexible cable: r&ge;6D</span></p>
<p style="text-align: left">&nbsp;</p>
<div style="text-align: center"><strong>&nbsp;</strong> <span style="font-size: 16.0px">Model,name and application </span></div>
<div style="overflow:auto"><table style="width: 757.0px;height: 469.0px" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 14.25pt" align="left">
<td style="width: 760.0pt" colspan="10">&nbsp;</td>
</tr>
<tr style="height: 15.75pt" align="left">
<td colspan="2">Model</td>
<td colspan="4">Name</td>
<td colspan="4">Main application</td>
</tr>
<tr style="height: 15.75pt" align="left">
<td colspan="2">KVV</td>
<td colspan="4">Copper conductor PVC insulated PVC sheathed control cable</td>
<td colspan="4">For laying indoors, in trenches and in ducts, for fixed&nbsp;&nbsp; installation</td>
</tr>
<tr style="height: 15.75pt" align="left">
<td colspan="2">KVVP</td>
<td colspan="4">Copper conductor PVC insulated PVC sheathed copper braiding screened control cable</td>
<td colspan="4">For laying indoors, in trenches and in dusts, for fixed installation</td>
</tr>
<tr style="height: 18.75pt" align="left">
<td colspan="2">KVVP<span><sub><span style="font-size: xx-small">2</span></sub></span></td>
<td colspan="4">Copper conductor PVC insulated and sheathed control cable with steel tape shield</td>
<td colspan="4">
<p>For laying indoors, in trenches and in dusts and in ground, able</p>
<p>to withstand heavier mechanical force, for fixed installation</p>
</td>
</tr>
<tr style="height: 18.75pt" align="left">
<td colspan="2">KVV<span><sub><span style="font-size: xx-small">22</span></sub></span></td>
<td colspan="4">Copper conductor PVC insulated and sheathed control cable with steel tape armour</td>
<td colspan="4">
<p>For laying indoors, in trenches and in dusts and in ground, able</p>
<p>to withstand heavier mechanical force, for fixed installation</p>
</td>
</tr>
<tr style="height: 15.75pt" align="left">
<td colspan="2">KVVR</td>
<td colspan="4">Copper conductor PVC insulated flexible control cable</td>
<td colspan="4">For laying indoors, movable and flexible</td>
</tr>
<tr style="height: 15.75pt" align="left">
<td colspan="2">ZR-KVVRP</td>
<td style="width: 410.0pt" colspan="4">Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable with braided shield</td>
<td colspan="4">Fixed laying indoors with capability of moving and screening</td>
</tr>
<tr style="height: 15.75pt" align="left">
<td colspan="2">ZR-KVV</td>
<td colspan="4">Copper conductor PVC insulated and sheathed flame retardant control cable</td>
<td colspan="4">
<p>For laying indoors, in trenches, in ducts and for fixed installation,</p>
<p>the cable should be flame retardant</p>
</td>
</tr>
<tr style="height: 18.75pt" align="left">
<td colspan="2">ZR-KVVP<span><sub><span style="font-size: xx-small">2</span></sub></span></td>
<td colspan="4">Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield</td>
<td colspan="4">
<p>For laying indoors, in trenches, in ducts and for fixed installation,</p>
<p>&nbsp;the cable should be flame retardant</p>
</td>
</tr>
<tr style="height: 18.75pt" align="left">
<td colspan="2">ZR-KVV<span><sub><span style="font-size: xx-small">22</span></sub></span></td>
<td colspan="4">Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armour</td>
<td colspan="4">
<p>For laying indoors, in trenches, in ducts and underground, the</p>
<p>cable should be flame-retardant and able to bear beavier</p>
<p>external mechanical force, and for fixed installation</p>
</td>
</tr>
<tr style="height: 15.75pt" align="left">
<td colspan="2">ZR-KVVR</td>
<td colspan="4">Copper conductor PVC insulated and sheathed flame retardant flexible control cable</td>
<td colspan="4">For laying indoors, and the cable should be flexible and movable</td>
</tr>
</tbody>