<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>copper wire braided screened control cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/copper-wire-braided-screened-control-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Mon, 28 Oct 2019 11:09:11 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>24 X 1.5 mm2 12 Core Copper PVC Insulated Control Cable</title>
		<link>https://www.baoliyy.com/24-x-1-5-mm2-12-core-copper-pvc-insulated-control-cable-2/</link>
				<comments>https://www.baoliyy.com/24-x-1-5-mm2-12-core-copper-pvc-insulated-control-cable-2/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 11:09:11 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[Copper PVC Insulated Control Cable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/24-x-1-5-mm2-12-core-copper-pvc-insulated-control-cable-2/</guid>
				<description><![CDATA[24 X 1.5 mm2 12 Core Copper PVC Insulated Control Cable &#160; Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="font-size: 24.0px">24 X 1.5 mm2 12 Core Copper PVC Insulated Control Cable</span></strong></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/24-x-1-5-mm2-12-core-copper-pvc-insulated-control-cable-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>Halogen free ZR-KVVP Control Cable</title>
		<link>https://www.baoliyy.com/halogen-free-zr-kvvp-control-cable-2/</link>
				<comments>https://www.baoliyy.com/halogen-free-zr-kvvp-control-cable-2/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 11:09:01 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[Halogen free ZR-KVVP Control Cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/halogen-free-zr-kvvp-control-cable-2/</guid>
				<description><![CDATA[Halogen free ZR-KVVP Control Cable &#160; Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control Cable: Conductor: Cu Insulation: [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="font-size: 24.0px">Halogen free ZR-KVVP Control Cable</span></strong></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/halogen-free-zr-kvvp-control-cable-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>Copper core PVC insulated cvv control cable</title>
		<link>https://www.baoliyy.com/copper-core-pvc-insulated-cvv-control-cable/</link>
				<comments>https://www.baoliyy.com/copper-core-pvc-insulated-cvv-control-cable/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 11:07:35 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[PVC insulated cvv control cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/copper-core-pvc-insulated-cvv-control-cable/</guid>
				<description><![CDATA[Copper core PVC insulated cvv control cable &#160; Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control Cable: Conductor: [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>Copper core PVC insulated cvv control cable</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/copper-core-pvc-insulated-cvv-control-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>Control cable PVC Insulation Copper Conductor</title>
		<link>https://www.baoliyy.com/control-cable-pvc-insulation-copper-conductor/</link>
				<comments>https://www.baoliyy.com/control-cable-pvc-insulation-copper-conductor/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 11:06:45 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[H03RN-F H05RN-F 4 cores rubber power cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/control-cable-pvc-insulation-copper-conductor/</guid>
				<description><![CDATA[Professional manufacture H03RN-F H05RN-F 4 cores rubber power cable &#160; Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 18.0px"><strong>Professional manufacture H03RN-F H05RN-F 4 cores rubber power cable</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/control-cable-pvc-insulation-copper-conductor/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>9 core cable PVC jacket control cable</title>
		<link>https://www.baoliyy.com/9-core-cable-pvc-jacket-control-cable-2/</link>
				<comments>https://www.baoliyy.com/9-core-cable-pvc-jacket-control-cable-2/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 11:04:48 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[9 core cable PVC jacket control cable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/9-core-cable-pvc-jacket-control-cable-2/</guid>
				<description><![CDATA[9 core cable PVC jacket control cable &#160; Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control Cable: Conductor: [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="font-size: 24.0px">9 core cable PVC jacket control cable</span></strong></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/9-core-cable-pvc-jacket-control-cable-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>0.75mm Armored Electrical Control Cable</title>
		<link>https://www.baoliyy.com/0-75mm-armored-electrical-control-cable/</link>
				<comments>https://www.baoliyy.com/0-75mm-armored-electrical-control-cable/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 11:04:45 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[Armored Electrical Control Cable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/0-75mm-armored-electrical-control-cable/</guid>
				<description><![CDATA[0.75mm Armored Electrical Control Cable &#160; Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control Cable: Conductor: Cu Insulation: [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 24.0px"><strong>0.75mm Armored Electrical Control Cable</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/0-75mm-armored-electrical-control-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>China manufacturer standard electric Multi core control cable</title>
		<link>https://www.baoliyy.com/china-manufacturer-standard-electric-multi-core-control-cable-2/</link>
				<comments>https://www.baoliyy.com/china-manufacturer-standard-electric-multi-core-control-cable-2/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 11:04:20 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[electric Multi core control cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/china-manufacturer-standard-electric-multi-core-control-cable-2/</guid>
				<description><![CDATA[China manufacturer standard electric Multi core control cable Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control Cable: Conductor: [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="font-size: 24.0px">China manufacturer standard electric Multi core control cable</span></strong></p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times;font-size: 24.0px"><strong>Application of Flexible Control Cable:</strong></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/china-manufacturer-standard-electric-multi-core-control-cable-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>PVC Insulated PVC Sheathed Armored Low Voltage Control Cable</title>
		<link>https://www.baoliyy.com/pvc-insulated-pvc-sheathed-armored-low-voltage-control-cable-4/</link>
				<comments>https://www.baoliyy.com/pvc-insulated-pvc-sheathed-armored-low-voltage-control-cable-4/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 11:03:57 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[PVC Sheathed Armored Low Voltage Control Cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/pvc-insulated-pvc-sheathed-armored-low-voltage-control-cable-4/</guid>
				<description><![CDATA[PVC Insulated PVC Sheathed Armored Low Voltage Control Cable &#160; Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 18.0px"><strong>PVC Insulated PVC Sheathed Armored Low Voltage Control Cable</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/pvc-insulated-pvc-sheathed-armored-low-voltage-control-cable-4/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>Highly Flexible Copper Conductor KVV Crane Control Cable</title>
		<link>https://www.baoliyy.com/highly-flexible-copper-conductor-kvv-crane-control-cable/</link>
				<comments>https://www.baoliyy.com/highly-flexible-copper-conductor-kvv-crane-control-cable/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 08:47:42 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[Copper Conductor KVV Crane Control Cable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/highly-flexible-copper-conductor-kvv-crane-control-cable/</guid>
				<description><![CDATA[Copper Conductor KVV Crane Control Cable Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control Cable: Conductor: Cu Insulation: [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="font-size: 24.0px">Copper Conductor KVV Crane Control Cable</span></strong></p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong><span style="line-height: 27.0px;font-family: arial , helvetica , sans-serif;font-size: 18.0px"></span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-l16vr" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-l16vr" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Related Products</span></div>
<div style="padding: 10.0px 0">
<div style="overflow:auto"><table style="background-color: #ffffff;width: 750.0px;border: 1.0px solid #cccccc">
<tbody>
<tr>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px;color: #000000">Electric Wire</span></td>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px;color: #000000">Control Cable</span></td>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px;color: #000000">Power Cable</span></td>
</tr>
<tr>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="color: #000000;font-family: arial , helvetica , sans-serif;font-size: 18.0px"></span></td>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="color: #000000;font-family: arial , helvetica , sans-serif;font-size: 18.0px"></span></td>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="color: #000000;font-family: arial , helvetica , sans-serif;font-size: 18.0px"></span></td>
</tr>
<tr>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="color: #000000;font-family: arial , helvetica , sans-serif;font-size: 18.0px">Aerial Bundled Cable</span></td>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="color: #000000;font-family: arial , helvetica , sans-serif;font-size: 18.0px">Aluminum Conductor</span></td>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px;text-align: center"><span style="color: #000000;font-family: arial , helvetica , sans-serif;font-size: 18.0px">Rubber Cable</span></td>
</tr>
<tr>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px"></span></td>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px"></span></td>
<td style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px;color: #000000;margin: 8.0px;border: 1.0px solid #cccccc;padding: 1.0px"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></td>
</tr>
</tbody>
</table></div>
<p><strong><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Which wire or cable is suitable for your project, please? Kindly click the model or leave a message below.</span></strong></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px"></span></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-0sy9z" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-0sy9z" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 16.0px">1. Packing in protective film coils or&nbsp;wooden/iron drums,&nbsp;water proof and dust proof..</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 16.0px">2. Packing in standard export &amp; import fumigated wooden drums or&nbsp;containers.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 16.0px">3. Customized package is welcomed, we accept your size and logo customization.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 16.0px">4. Shipping by air, sea or train, depending delivery time and your project requirement.</span></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-sdkoa" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-sdkoa" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
</div>
</div>
<div id="ali-anchor-AliPostDhMb-qe9gp" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-qe9gp" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Contact Us</span></div>
<div style="padding: 10.0px 0">
<p><strong><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px;color: #008000">Please free to click and send us your requirement about <span style="text-decoration: underline">electric wires and power cables</span>. Any questions will be replied within 24 hours.</span></strong></p>
<p><strong><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px;color: #008000"><span style="line-height: 27.0px;font-family: arial , helvetica , sans-serif;font-size: 18.0px"></span></span></strong></p>
</div>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/highly-flexible-copper-conductor-kvv-crane-control-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>0.6/1 KV 1.5mm2 2.5mm2 flexible copper conductor control cable hot sale</title>
		<link>https://www.baoliyy.com/0-6-1-kv-1-5mm2-2-5mm2-flexible-copper-conductor-control-cable-hot-sale-2/</link>
				<comments>https://www.baoliyy.com/0-6-1-kv-1-5mm2-2-5mm2-flexible-copper-conductor-control-cable-hot-sale-2/#respond</comments>
				<pubDate>Mon, 28 Oct 2019 08:47:21 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[guowangcable]]></category>
		<category><![CDATA[copper wire braided screened control cable]]></category>
		<category><![CDATA[flexible copper conductor control cable hot sale]]></category>
		<category><![CDATA[Signal control cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/0-6-1-kv-1-5mm2-2-5mm2-flexible-copper-conductor-control-cable-hot-sale-2/</guid>
				<description><![CDATA[flexible copper conductor control cable hot sale &#160; Product Description Application of Flexible Control Cable: Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &#38; line protection when the rated voltage is 450/750 or less. &#160; Standards of Flexible Control Cable: IEC502, IEC332-3 &#160; Struction of Flexible Control Cable: Conductor: [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>flexible copper conductor control cable hot sale</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-pp6kt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-pp6kt" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: times new roman , times"><span style="font-size: medium"><strong>Application of Flexible Control Cable:</strong></span></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Copper Conductor PVC Insulated and Sheathed Control cable is used for control, loop control &amp; line protection when the rated voltage is 450/750 or less.</span></span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Standards of Flexible Control Cable: </span></strong><span style="font-size: medium">IEC502, IEC332-3</span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times"><span style="font-size: medium">Struction of Flexible Control Cable:</span></span></strong></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Conductor: </span></strong><span style="font-size: medium">Cu</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Insulation:</span></strong><span style="font-size: medium"> PVC ( polyvinyl chloride )</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath: </span></strong><span style="font-size: medium">PVC (polyvinyl chloride)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Sheath Color: </span></strong><span style="font-size: medium">Black or Gray (Bespoke cable)</span><strong><span style="font-size: medium">&nbsp;</span></strong></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Bending Radius: </span></strong></span></p>
<p><span style="font-family: times new roman , times"><span style="font-size: medium">Single core: 20D &plusmn; 0.05, multi-core: 15D &plusmn; 0.05</span></span></p>
<p><span style="font-family: times new roman , times"><strong><span style="font-size: medium">Temperature Rating: </span></strong><span style="font-size: medium">0&deg;C to 90&deg;C</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , serif;font-size: 13.5pt">Type&amp; Specification of Flexible Control Cable</span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 12.0pt">&nbsp;</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Type</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Name</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Section Area(mm2)</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">No. of Core</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Application Site</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded&nbsp; Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KVVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-16</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">2-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJV22</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVP2</span></p>
</td>
<td rowspan="3">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.75 1.0 1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">7-61</span></p>
</td>
<td rowspan="3" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Permanent installation indoors,in cable ditches or pipes where shielding is required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4 6</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-14</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">10</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-10</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVR</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5-2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">Installation indoors where flexibility and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">KYJVRP</span></p>
</td>
<td rowspan="2">
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">0.5 0.75 1.0</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-61</span></p>
</td>
<td rowspan="2" align="left">
<p><span style="font-family: times new roman , serif;font-size: 10.5pt">&nbsp;Installation indoors where flexibility shielding and movability are required</span></p>
</td>
</tr>
<tr align="center">
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">1.5 2.5</span></p>
</td>
<td>
<p align="center"><span style="font-family: times new roman , serif;font-size: 10.5pt">4-48</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 14.0px"><strong>&nbsp;</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><strong>&nbsp;&nbsp;&nbsp; ALL KINDS OF CONTROL CABLES</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-s4rzi" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-s4rzi" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-wxa1f" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-wxa1f" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Company Information</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp; &nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 14.0px"><span style="font-size: 16.0px">As one of top rank cables manufacturers in China, Henan Guowang Cable is mainly specialized in PVC Insulated Building Wire, PVC and XLPE Insulated Power Cable with Voltage up to 35kV, Rubber Cable and Welding Cables. And also it is mainly specialized in Aerial Bundled Cable(ABC Cable), Bare Overhead Power Transmission Line such as triplex overhead service conductors(<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), All Aluminum Alloy Conductor(A<a href="https://www.gecable.com/aac-all-aluminum-conductor/">AAC Conductor</a>), Aluminum Conductor Steel Reinforced(<a href="https://www.gecable.com/acsr-aluminum-conductor-steel-reinforced/">ACSR Conductor</a>), Aluminum Conductor Aluminum Clad Steel Reinforced (ACSR/AW), All Aluminum Alloy Steel Reinforced(AACSR), and Aluminum Conductor Aluminum Alloy Reinforced(ACAR).</span> </span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp; Our Factory and Customers</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-4ngrx" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4ngrx" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Our Services</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">&nbsp;<span style="font-family: times new roman , times;font-size: 16.0px">1. Sufficient support for our tendering representatives.</span></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;2.&nbsp;Qualification documents support</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;3.OEM service available based on official &amp; legal authorization.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;4. Strict quality control system.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;5. Faster lead time than our competitors.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;6. Excellent quality with reasonable price.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;7. Strong technical support (technical data, drawing, etc.)</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;8. Cable solutions to your particular requirements.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">&nbsp;9. Free sample is available with economic express fee.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">10. Factory acceptance test assistant.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">11. Container loading design and handling.</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px">&nbsp;ISO 9001&nbsp; ISO 14001&nbsp; OHSAS18001 and CCC Certification:</span></strong></p>
<p><strong><span style="font-family: times new roman , times;font-size: 18.0px"></span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5pyv6" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5pyv6" style="padding: 8.0px 0"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">1).When can I get the price?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">call us or tell us in your e-mail so that we will regard your inquiry priority.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(2).How can I get a sample to check your quality?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After price confirmation, you can require for samples to check our quality. Sample is free, but the freight</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">charge should be paid.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(3).How long can I expect to get the sample?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express&nbsp;</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">account&nbsp;orprepay us if you do not have an account.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">(4).What about the lead time for mass production?</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Honestly, it depends on the order quantity and the season you place the order.The best record we keep is</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months </span><span style="font-family: times new roman , times;font-size: 16.0px">before the date you would like to get the products at your country.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px"><strong><span style="font-family: times new roman , times">Contact ways:</span></strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/0-6-1-kv-1-5mm2-2-5mm2-flexible-copper-conductor-control-cable-hot-sale-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
