<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>copper braiding shielded cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/copper-braiding-shielded-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Sat, 28 Sep 2019 05:24:14 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>flexible control cable copper conductor braiding shielded cable</title>
		<link>https://www.baoliyy.com/flexible-control-cable-copper-conductor-braiding-shielded-cable/</link>
				<comments>https://www.baoliyy.com/flexible-control-cable-copper-conductor-braiding-shielded-cable/#respond</comments>
				<pubDate>Sat, 28 Sep 2019 05:24:14 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shcable]]></category>
		<category><![CDATA[braiding shielded cable]]></category>
		<category><![CDATA[control cable braiding shielded cable]]></category>
		<category><![CDATA[copper braiding shielded cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/flexible-control-cable-copper-conductor-braiding-shielded-cable/</guid>
				<description><![CDATA[&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160; flexible control cable copper conductor braiding shielded cable &#160; Specifications 1 GB,IEC,AS,BS,VDE Standard&#160;2 Professional QC inspection 3 On time delivery Application Used&#160;as&#160;power&#160;and&#160;connecting&#160;cables&#160;in&#160;mechanical&#160;engineering&#160;for&#160;tooling&#160;machinery,&#160;control&#160;unit,&#160;production&#160;lines,&#160;transportation&#160;equipment,&#160;conveyor&#160;and&#160;assembly&#160;lines&#160; as&#160;well&#160;as&#160;in&#160;plant&#160;construction&#160;under&#160;the&#160;circumstance&#160;that&#160;the&#160;rated&#160;voltage&#160;is&#160;up&#160;to&#160;450/750V&#160;AC. Character&#160;and&#160;Relevant&#160;Parameters 1.&#160;Long-term&#160;service&#160;temperature&#160;of&#160;the&#160;cable&#160;conductor:&#160;70&#160;0C 2.&#160;Rated&#160;voltage:&#160;450/750V 3.&#160;Cable&#160;lying&#160;temperature&#160;&#8805;0&#160;0C 4.&#160;Cores:&#160;2,&#160;3,&#160;4,&#160;5,&#160;6,7,&#160;8,&#160;10,&#160;12,&#160;14,&#160;16,&#160;19,&#160;24,&#160;27,&#160;30,&#160;37,&#160;44,&#160;48,&#160;52,&#160;61 5.&#160;Minimun&#160;bending&#160;radius: Non&#160;armored&#160;&#8805;&#160;out&#160;diameter&#160;of&#160;cable&#160;6&#160;times Armored&#160;layer&#160;or&#160;copper&#160;tape&#160;shielded&#160;&#8805;&#160;outer&#160;diameter&#160;of&#160;cable&#160;12&#160;times Shielded&#160;layer&#160;soft&#160;cable&#160;&#8805;&#160;outer&#160;diameter&#160;of&#160;cable&#160;6&#160;times PVC&#160;Insulated&#160;Control&#160;Cable&#160;Parameter Type &#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160; Name Section&#160;Area (mm2) No.&#160;of &#160;Core &#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160; Application&#160;Site KVV Copper&#160;Conductor,PVC&#160;Insulated&#160;and &#160;Sheathed&#160;Control&#160;Cable 0.75&#160;1.0&#160;1.5&#160;2.5 2-16 Permanent&#160;installation&#160;indoors, in&#160;cable&#160;ditches&#160;or&#160;pipes 4&#160;6 2-14 10 2-10 KVVP [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h3><span style="font-size: 24.0px;color: #ff6600">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; flexible control cable copper conductor braiding shielded cable <br /></span></h3>
<h3>&nbsp;</h3>
<h3><span style="font-size: 16.0px"><strong>Specifications</strong></span></h3>
<p>1 GB,IEC,AS,BS,VDE Standard&nbsp;<br />2 Professional QC inspection <br />3 On time delivery</p>
<div>
<p><span style="font-size: 14.0pt"><span style="font-family: arial black"><strong>Application</strong></span></span></p>
<p>Used&nbsp;as&nbsp;power&nbsp;and&nbsp;connecting&nbsp;cables&nbsp;in&nbsp;mechanical&nbsp;engineering&nbsp;for&nbsp;tooling&nbsp;machinery,&nbsp;control&nbsp;unit,&nbsp;production&nbsp;lines,&nbsp;transportation&nbsp;equipment,&nbsp;conveyor&nbsp;and&nbsp;assembly&nbsp;lines&nbsp;</p>
<p>as&nbsp;well&nbsp;as&nbsp;in&nbsp;plant&nbsp;construction&nbsp;under&nbsp;the&nbsp;circumstance&nbsp;that&nbsp;the&nbsp;rated&nbsp;voltage&nbsp;is&nbsp;up&nbsp;to&nbsp;450/750V&nbsp;AC.</p>
<p><strong><span style="font-family: arial black"><span style="font-size: 14.0pt">Character&nbsp;and&nbsp;Relevant&nbsp;Parameters</span></span></strong></p>
<p>1.&nbsp;Long-term&nbsp;service&nbsp;temperature&nbsp;of&nbsp;the&nbsp;cable&nbsp;conductor:&nbsp;70&nbsp;0C</p>
<p>2.&nbsp;Rated&nbsp;voltage:&nbsp;450/750V</p>
<p>3.&nbsp;Cable&nbsp;lying&nbsp;temperature&nbsp;&ge;0&nbsp;0C</p>
<p>4.&nbsp;Cores:&nbsp;2,&nbsp;3,&nbsp;4,&nbsp;5,&nbsp;6,7,&nbsp;8,&nbsp;10,&nbsp;12,&nbsp;14,&nbsp;16,&nbsp;19,&nbsp;24,&nbsp;27,&nbsp;30,&nbsp;37,&nbsp;44,&nbsp;48,&nbsp;52,&nbsp;61</p>
<p>5.&nbsp;Minimun&nbsp;bending&nbsp;radius:</p>
<p>Non&nbsp;armored&nbsp;&ge;&nbsp;out&nbsp;diameter&nbsp;of&nbsp;cable&nbsp;6&nbsp;times</p>
<p>Armored&nbsp;layer&nbsp;or&nbsp;copper&nbsp;tape&nbsp;shielded&nbsp;&ge;&nbsp;outer&nbsp;diameter&nbsp;of&nbsp;cable&nbsp;12&nbsp;times</p>
<p>Shielded&nbsp;layer&nbsp;soft&nbsp;cable&nbsp;&ge;&nbsp;outer&nbsp;diameter&nbsp;of&nbsp;cable&nbsp;6&nbsp;times</p>
<p><strong><span style="font-family: arial black"><span style="font-size: 14.0pt">PVC&nbsp;Insulated&nbsp;Control&nbsp;Cable&nbsp;Parameter</span></span></strong></p>
<div style="overflow:auto"><table style="width: 618.0px;height: 584.0px" border="0">
<tbody>
<tr>
<td>
<p>Type</p>
</td>
<td>
<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Name</p>
</td>
<td>
<p>Section&nbsp;Area</p>
<p>(mm2)</p>
</td>
<td>
<p>No.&nbsp;of</p>
<p>&nbsp;Core</p>
</td>
<td>
<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Application&nbsp;Site</p>
</td>
</tr>
<tr>
<td rowspan="3">
<p>KVV</p>
</td>
<td rowspan="3">
<p>Copper&nbsp;Conductor,PVC&nbsp;Insulated&nbsp;and</p>
<p>&nbsp;Sheathed&nbsp;Control&nbsp;Cable</p>
</td>
<td>
<p>0.75&nbsp;1.0&nbsp;1.5&nbsp;2.5</p>
</td>
<td>
<p>2-16</p>
</td>
<td rowspan="3">
<p>Permanent&nbsp;installation&nbsp;indoors,</p>
<p>in&nbsp;cable&nbsp;ditches&nbsp;or&nbsp;pipes</p>
</td>
</tr>
<tr>
<td>
<p>4&nbsp;6</p>
</td>
<td>
<p>2-14</p>
</td>
</tr>
<tr>
<td>
<p>10</p>
</td>
<td>
<p>2-10</p>
</td>
</tr>
<tr>
<td rowspan="3">
<p>KVVP</p>
</td>
<td rowspan="3">
<p>Copper&nbsp;Conductor,PVC&nbsp;Insulated&nbsp;</p>
<p>and&nbsp;Sheathed,</p>
<p>Braiding&nbsp;Shielded&nbsp;&nbsp;Control&nbsp;Cable</p>
</td>
<td>
<p>0.75&nbsp;1.0&nbsp;1.5&nbsp;2.5</p>
</td>
<td>
<p>2-61</p>
</td>
<td rowspan="3">
<p>Permanent&nbsp;installation&nbsp;indoors</p>
<p>in&nbsp;cableditches&nbsp;or&nbsp;pipes&nbsp;where</p>
<p>&nbsp;shielding&nbsp;is&nbsp;required</p>
</td>
</tr>
<tr>
<td>
<p>4&nbsp;6</p>
</td>
<td>
<p>2-14</p>
</td>
</tr>
<tr>
<td>
<p>10</p>
</td>
<td>
<p>2-10</p>
</td>
</tr>
<tr>
<td rowspan="3">
<p>KVVP2</p>
</td>
<td rowspan="3">
<p>Copper&nbsp;Conductor,PVC&nbsp;Insulated&nbsp;</p>
<p>and&nbsp;Sheathed,</p>
<p>Copper-tape&nbsp;Screened&nbsp;Control&nbsp;Cable</p>
</td>
<td>
<p>0.75&nbsp;1.0&nbsp;1.5&nbsp;2.5</p>
</td>
<td>
<p>4-10</p>
</td>
<td rowspan="3">
<p>Permanent&nbsp;installation&nbsp;indoors</p>
<p>,incable&nbsp;ditchesor&nbsp;pipes&nbsp;where&nbsp;</p>
<p>shielding&nbsp;is&nbsp;required</p>
</td>
</tr>
<tr>
<td>
<p>4&nbsp;6</p>
</td>
<td>
<p>7-61</p>
</td>
</tr>
<tr>
<td>
<p>10</p>
</td>
<td>
<p>4-10</p>
</td>
</tr>
<tr>
<td rowspan="3">
<p>KVV22</p>
</td>
<td rowspan="3">
<p>Copper&nbsp;Conductor,PVC&nbsp;Insulated</p>
<p>&nbsp;and&nbsp;Sheathed,</p>
<p>Steel&nbsp;tape&nbsp;Armored&nbsp;Control&nbsp;Cable</p>
</td>
<td>
<p>0.75&nbsp;1.0&nbsp;1.5&nbsp;2.5</p>
</td>
<td>
<p>7-61</p>
</td>
<td rowspan="3">
<p>Permanent&nbsp;installation&nbsp;indoors,</p>
<p>in&nbsp;cable&nbsp;ditches,Be&nbsp;able&nbsp;to</p>
<p>withstand&nbsp;stronger</p>
<p>&nbsp;external&nbsp;mechanical&nbsp;force</p>
</td>
</tr>
<tr>
<td>
<p>4&nbsp;6</p>
</td>
<td>
<p>4-14</p>
</td>
</tr>
<tr>
<td>
<p>10</p>
</td>
<td>
<p>4-14</p>
</td>
</tr>
<tr>
<td>
<p>KVVR</p>
</td>
<td>
<p>Copper&nbsp;Conductor,PVC&nbsp;Insulated&nbsp;</p>
<p>and&nbsp;Sheathed,</p>
<p>Flexible&nbsp;Control&nbsp;Cable</p>
</td>
<td>
<p>0.5-2.5</p>
</td>
<td>
<p>4-61</p>
</td>
<td>
<p>Installation&nbsp;indoors&nbsp;where&nbsp;</p>
<p>flexibility&nbsp;and&nbsp;</p>
<p>movability&nbsp;are&nbsp;required</p>
</td>
</tr>
<tr>
<td>
<p>KVVRP</p>
</td>
<td>
<p>Copper&nbsp;Conductor,PVC&nbsp;Insulated&nbsp;</p>
<p>and&nbsp;Sheathed,</p>
<p>Braiding&nbsp;shielded&nbsp;Flexible&nbsp;Control&nbsp;Cable</p>
</td>
<td>
<p>0.5&nbsp;0.75&nbsp;1.0</p>
</td>
<td>
<p>4-61</p>
</td>
</tr>
</tbody>
</table></div>
</div>
<p>&nbsp;</p>
</p>
<p>&nbsp;</p>
</p>
</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-0b2qt" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-0b2qt" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">contacts</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-family: comic sans ms , sans-serif;color: #ff6600;font-size: 16.0px;background-color: #ffffff"><em>Dear sir or madam</em></span></p>
<p><span style="font-family: comic sans ms , sans-serif;color: #ff6600;font-size: 18.0px;background-color: #ffffff"><span style="font-size: 16.0px"><em>This is cherry. If you have a</em>ny problem , please feel free to contact me. Tell us your request ! Let me know your needs !&nbsp;<span style="font-family: comic sans ms , sans-serif;color: #ff6600;background-color: #ffffff"><strong> RIGHT NOW !!<span style="font-family: comic sans ms , sans-serif;color: #ff6600;background-color: #ffffff">&nbsp;&nbsp; <span style="font-family: comic sans ms , sans-serif;color: #ff6600;background-color: #ffffff"><strong>ACTION ! &nbsp; </strong></span></span>please !</strong> </span></span><br /></span></p>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px;background-color: #ffff00;color: #000000">&nbsp;</span></p>
</div>
</div>
<p><map name="9851"></map>
</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/flexible-control-cable-copper-conductor-braiding-shielded-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
