<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aromoured Power Cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/aromoured-power-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Mon, 16 Sep 2019 01:44:19 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>46KV Concentric Power Cable with 100% insulation level 500MCM</title>
		<link>https://www.baoliyy.com/46kv-concentric-power-cable-with-100-insulation-level-500mcm/</link>
				<comments>https://www.baoliyy.com/46kv-concentric-power-cable-with-100-insulation-level-500mcm/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 01:44:19 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[Aromoured Power Cable]]></category>
		<category><![CDATA[Concentric Power Cable]]></category>
		<category><![CDATA[mv power cable]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/46kv-concentric-power-cable-with-100-insulation-level-500mcm/</guid>
				<description><![CDATA[&#160; Product Description &#160; 1. Introduction: &#160; &#160; &#160;Cross-linked polyethylene insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress. Its structure is simple. The long term operating temperature is 90oC. It is convenient to use and can be laid with no [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-vjflu" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-vjflu" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Product Description</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<p><span style="line-height: 21.111113px;font-size: 14.0px">1. Introduction:</span></p>
<p><span style="line-height: 21.111113px;font-size: 14.0px">&nbsp; &nbsp; &nbsp;Cross-linked polyethylene insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress. Its structure is simple. The long term operating temperature is 90<sup>o</sup>C. It is convenient to use and can be laid with no restriction of different level.</span></p>
<p><span style="line-height: 21.111113px;font-size: 14.0px">&nbsp; &nbsp; &nbsp;Our enterprise can produce both flame retardant and non-flame retardant series of XLPE power cable.</span></p>
<p><span style="line-height: 21.111113px;font-size: 14.0px">&nbsp; &nbsp; &nbsp;Our XLPE power cable can be produced according to your specifications, which are equivalent to IEC, DIN, BS and ASTM, and some indexes are surperior to standards stated above.</span></p>
<p><span style="line-height: 21.111113px;font-size: 14.0px">&nbsp; &nbsp; &nbsp;The flame-retardant cable coves all kinds of low-smoke lowe-halogen, low-smoke halogen free and three classes of A, B ,C.</span></p>
<p><span style="line-height: 21.111113px;font-size: 14.0px">&nbsp; &nbsp; &nbsp;We can design and manufacture special XLPE cable according to other standards required by the customers, such as Heavy section cut apart conductors, water-resistance, defend termites, defend mouse and so on.</span></p>
<p><span style="line-height: 21.111113px;font-size: 14.0px;font-family: verdana , arial , helvetica , sans-serif">2. Application and Main type</span></p>
<div style="overflow:auto"><table style="width: 722.0px;height: 1196.0px" border="1">
<tbody>
<tr>
<td colspan="2" align="center">Type</td>
<td rowspan="2" align="center">Description</td>
<td rowspan="2" align="center">Main Apllication</td>
</tr>
<tr>
<td align="center">Copper Conductor</td>
<td align="center">Aluminum Conductor</td>
</tr>
<tr>
<td align="center">
<p>YJV</p>
<p><span style="line-height: normal">Cu/XLPE/PVC</span></p>
</td>
<td align="center">
<p>YJLV</p>
<p>Al/XLPE/PVC</p>
</td>
<td>
<p>Copper or aluminum conductor</p>
<p>XLPE insulated, Copper tape</p>
<p>screen PVC shealthed power cable</p>
</td>
<td rowspan="3">
<p>For laying indoor, tunnel, underground and cannel.</p>
<p>Unable to bear external mechanical pulling force and pressure during laid.</p>
</td>
</tr>
<tr>
<td align="center">
<p>YJV</p>
<p><span style="line-height: normal">Cu/XLPE/L(H)DPE</span></p>
</td>
<td align="center">
<p>YJLV</p>
<p><span style="line-height: normal"><span style="line-height: normal">Al</span>/XLPE/L(H)DPE</span></p>
</td>
<td>
<p>Copper or aluminum conductor&nbsp;</p>
<p>XLPE insulated, Copper tape&nbsp;<span style="line-height: 20.0px;font-size: 12.0px">screen</span></p>
<p><span style="line-height: 20.0px;font-size: 12.0px">PE/LDPE/HDPE shealthed power cable</span></p>
</td>
</tr>
<tr>
<td align="center">
<p>YJE</p>
<p><span style="line-height: normal">Cu/XLPE/LSOH</span></p>
</td>
<td align="center">
<p>YJLE</p>
<p><span style="line-height: normal">Al/XLPE/LSOH</span></p>
</td>
<td>
<p>Copper&nbsp;<span style="line-height: normal">or aluminum conductor XLPE</span></p>
<p>insulated, Copper tape</p>
<p>screen LSOH shealthed power cable</p>
</td>
</tr>
<tr>
<td align="center">
<p>YJSV</p>
<p>Cu/XLPE/CWS/PVC</p>
<p>N2XS(SE)Y</p>
</td>
<td align="center">
<p>YJLSV</p>
<p>Al/XLPE/CWS/PVC</p>
<p>N2XS(SE)Y</p>
</td>
<td>
<p>Copper&nbsp;<span style="line-height: normal">or aluminum conductor XLPE</span></p>
<p>insulated, Copper wire+Coper tape</p>
<p>screen PVC shealthed power cable</p>
</td>
<td rowspan="3">&nbsp;&nbsp;&nbsp; </p>
<p>For laying indoor, tunnel, underground and cannel.</p>
<p>Unable to bear external mechanical pulling force and pressure during laid, fault current requires large.</p>
<p>CWS(Copper wire screen)</p>
<p>type:A: Fixed section&nbsp;</p>
<p>B: Full/one third/one sixth/one eighth/one sixteenth neutral</p>
</td>
</tr>
<tr>
<td align="center">
<p>YJSY</p>
<p>Cu/XLPE/CWS/L(M.H)DPE</p>
<p>N2XS(SE)2Y</p>
</td>
<td align="center" valign="top">&nbsp; </p>
<p>YJLSY</p>
<p>Al/XLPE/CWS/L(M.H)DPE</p>
<p>N2XS(SE)2Y</p>
</td>
<td>
<p>C<span style="line-height: normal">opper&nbsp;<span style="line-height: normal">or aluminum conductor XLPE</span><br /></span></p>
<p>insulated, Copper wire+Coper tape</p>
<p>screen&nbsp;<span style="line-height: 20.0px">PE/LDPE/HDPE</span>&nbsp;shealthed power cable</p>
</td>
</tr>
<tr>
<td align="center">
<p>&nbsp;YJE</p>
<p>Cu/XLPE/CWS/LSOH</p>
</td>
<td align="center">
<p>YJLE</p>
<p><span style="line-height: normal">Al/XLPE/CWS/LSOH</span>&nbsp;</p>
</td>
<td>
<p>Copper&nbsp;<span style="line-height: normal">or aluminum conductor XLPE</span></p>
<p>Copper wire+Coper tape</p>
<p>screen LSOH shealthed power cable</p>
</td>
</tr>
<tr>
<td align="center">
<p>YJV22</p>
<p><span style="line-height: normal">Cu/XLPE/STA/PVC</span></p>
</td>
<td align="center">
<p>YJLV22</p>
<p><span style="line-height: normal">&nbsp;</span><span style="line-height: normal">Al/XLPE/STA/PVC</span>&nbsp;</p>
</td>
<td>
<p>C<span style="line-height: normal">opper&nbsp;</span><span style="line-height: normal">or aluminum conductor XLPE</span></p>
<p>insulated, Copper tape screen, steel tape armoured, PVC sheathed power cable</p>
</td>
<td rowspan="3">&nbsp;&nbsp;&nbsp; </p>
<p>For laying indoor, tunnel, underground and cannel.</p>
<p>Able to bear external mechanical forces, but unable to bear large pulling force.</p>
</td>
</tr>
<tr>
<td align="center">
<p>&nbsp;YJV23</p>
<p><span style="line-height: normal">&nbsp;</span><span style="line-height: normal">Cu/XLPE/STA/L(M.H)PE</span></p>
</td>
<td align="center">
<p>YJLV23</p>
<p><span style="line-height: normal">Al/XLPE/STA/L(M.H)PE</span>&nbsp;</p>
</td>
<td>
<p>C<span style="line-height: normal">opper&nbsp;</span><span style="line-height: normal">or aluminum conductor XLPE</span></p>
<p><span style="line-height: normal">insulated, Copper tape screen, steel tape armoured,&nbsp;<span style="line-height: 20.0px">PE/LDPE/HDPE&nbsp;</span>sheathed power cable</span></p>
</td>
</tr>
<tr>
<td align="center">
<p>&nbsp;WD-YJY23</p>
<p><span style="line-height: normal">Cu/XLPE/STA/LSOH</span></p>
</td>
<td align="center">
<p>WD-YJLY23</p>
<p><span style="line-height: normal">Al/XLPE/STA/LSOH</span>&nbsp;</p>
</td>
<td>
<p>C<span style="line-height: normal">opper&nbsp;</span><span style="line-height: normal">or aluminum conductor XLPE&nbsp;</span><span style="line-height: normal;font-size: 12.0px">insulated, Copper tape screen, steel tape armoured, PVC sheathed power cable</span></p>
<p>&nbsp;</p>
</td>
</tr>
<tr>
<td align="center">
<p>&nbsp;YJSV22</p>
<p><span style="line-height: normal">Cu/XLPE/CWS/STA/PVC</span></p>
<p>N2XSEBY</p>
</td>
<td align="center">
<p>YJLSV22</p>
<p><span style="line-height: normal">Al/XLPE/CWS/STA/PVC</span></p>
<p>N2XSEBY<span style="line-height: 20.0px;font-size: 12.0px">&nbsp;</span></p>
</td>
<td>
<p>C<span style="line-height: normal">opper&nbsp;</span><span style="line-height: normal">or aluminum conductor XLPE&nbsp;</span><span style="line-height: normal;font-size: 12.0px">insulated,</span></p>
<p>Copper wire+Coper tape&nbsp;<span style="line-height: 20.0px;font-size: 12.0px">screen,steel tape armoured, PVC</span><span style="line-height: 20.0px;font-size: 12.0px">&nbsp;shealthed power cable</span></p>
</td>
<td>&nbsp; </p>
<p>For laying indoor, tunnel, underground and cannel.</p>
<p>Able to bear external mechanical forces, but unable to bear large pulling force. fault current requires large.</p>
<p>CWS(Copper wire screen)</p>
<p>type:A: Fixed section&nbsp;</p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="line-height: 21.111113px;font-size: 14.0px">3. Scope of voltge grade and core number and cross-section</span></p>
<p><span style="line-height: 21.111113px;font-size: 14.0px">&nbsp; &nbsp;a) National standard</span></p>
<div style="overflow:auto"><table style="width: 725.0px;height: 184.0px" border="1">
<tbody>
<tr>
<td colspan="2" align="center" valign="middle">Rated voltage(kv)</td>
<td align="center" valign="middle">3.6/6</td>
<td align="center" valign="middle">6/6</td>
<td align="center" valign="middle">6/10</td>
<td align="center" valign="middle">8.7/10</td>
<td align="center" valign="middle">8.7/15</td>
<td align="center" valign="middle">12/15</td>
<td align="center" valign="middle">12/20</td>
<td align="center" valign="middle">18/20</td>
<td align="center" valign="middle">18/30</td>
<td align="center" valign="middle">21/35</td>
<td align="center" valign="middle">26/35</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle">Core Number</td>
<td colspan="11" align="center" valign="middle">1 core, 3 core</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle">
<p><span style="line-height: normal">Cross-section</span></p>
<p>mm<sup>2</sup></p>
</td>
<td align="center" valign="middle">1C</td>
<td colspan="3" align="center" valign="middle">25~800</td>
<td colspan="8" align="center" valign="middle">35~800</td>
</tr>
<tr>
<td align="center" valign="middle">3C</td>
<td colspan="3" align="center" valign="middle">25~400</td>
<td colspan="8" align="center" valign="middle">35~400</td>
</tr>
</tbody>
</table></div>
<p>&nbsp; b) IEC/BS/DIN standard</p>
<div style="overflow:auto"><table style="width: 727.0px;height: 180.0px" border="1">
<tbody>
<tr>
<td colspan="2" align="center" valign="middle">Rated voltage(kv)</td>
<td align="center" valign="middle">3.6/6</td>
<td align="center" valign="middle">6/6</td>
<td align="center" valign="middle">6/10</td>
<td align="center" valign="middle">8.7/10</td>
<td align="center" valign="middle">8.7/15</td>
<td align="center" valign="middle">12/15</td>
<td align="center" valign="middle">12/20</td>
<td align="center" valign="middle">18/20</td>
<td align="center" valign="middle">18/30</td>
<td align="center" valign="middle">21/35</td>
<td align="center" valign="middle">26/35</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle">Core Number</td>
<td colspan="11" align="center" valign="middle">1 core, 3 core</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle">
<p><span style="line-height: normal">Cross-section</span></p>
<p>mm<span style="line-height: 20.0px;font-size: 10.0px"><sup>2</sup></span></p>
</td>
<td align="center" valign="middle">1C</td>
<td colspan="3" align="center" valign="middle">25~800</td>
<td colspan="8" align="center" valign="middle">35~800</td>
</tr>
<tr>
<td align="center" valign="middle">3C</td>
<td colspan="3" align="center" valign="middle">25~400</td>
<td colspan="8" align="center" valign="middle">35~400</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp; c) ASTM standard</p>
<div style="overflow:auto"><table style="width: 706.0px;height: 179.0px" border="1">
<tbody>
<tr>
<td colspan="2" align="center" valign="middle"><span style="line-height: normal">Rated voltage(kv)</span></td>
<td align="center" valign="middle">5001-8000</td>
<td align="center" valign="middle">8001-15000</td>
<td align="center" valign="middle">15001-25000</td>
<td align="center" valign="middle">25001-28000</td>
<td align="center" valign="middle">28001-35000</td>
<td align="center" valign="middle">35001-46000</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle">&nbsp;</td>
<td colspan="6" align="center" valign="middle"><span style="line-height: normal">1 core, 3 core</span></td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle">
<p><span style="line-height: normal">Cross-section</span></p>
<p>mm<span style="line-height: 20.0px;font-size: 10.0px"><sup>2</sup></span></p>
</td>
<td align="center" valign="middle">
<p><span style="line-height: normal">1C</span></p>
<p>&nbsp;</p>
</td>
<td align="center" valign="middle">6AWG~1600kcmil</td>
<td align="center" valign="middle"><span style="line-height: normal">2AWG~1600kcmil</span></td>
<td colspan="2" align="center" valign="middle"><span style="line-height: normal">1AWG~1600kcmil</span></td>
<td align="center" valign="middle"><span style="line-height: normal">2AWG~1600kcmil</span></td>
<td align="center" valign="middle"><span style="line-height: normal">1/0AWG~1600kcmil</span></td>
</tr>
<tr>
<td align="center" valign="middle">
<p>&nbsp;</p>
<p><span style="line-height: normal">3C</span></p>
</td>
<td align="center" valign="middle">&nbsp;6AWG~1600kcmil</td>
<td align="center" valign="middle">2AWG~1600kcmil&nbsp;</td>
<td colspan="2" align="center" valign="middle"><span style="line-height: normal">1AWG~1600kcmil</span></td>
<td align="center" valign="middle"><span style="line-height: normal">2AWG~1600kcmil</span></td>
<td align="center" valign="middle"><span style="line-height: normal">4/0AWG~1600kcmil</p>
<p></span></td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>4. D.C Resistance of finished cable at 20<sup>o</sup>C per km is not more than following:</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="width: 729.0px;height: 508.0px" border="1">
<tbody>
<tr>
<td colspan="2" align="center" valign="middle">
<p>Nominal Cross-section</p>
<p>mm<sup>2</sup></p>
</td>
<td align="center" valign="middle">25</td>
<td align="center" valign="middle">35</td>
<td align="center" valign="middle">50</td>
<td align="center" valign="middle">70</td>
<td align="center" valign="middle">95</td>
<td align="center" valign="middle">120</td>
<td align="center" valign="middle">150</td>
<td align="center" valign="middle">185</td>
<td align="center" valign="middle">240</td>
<td align="center" valign="middle">300</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle">
<p>20<sup>o</sup>C DC Resistance</p>
<p>&Omega;/km</p>
</td>
<td align="center" valign="middle">Cu</td>
<td align="center" valign="middle">0.727</td>
<td align="center" valign="middle">0.524</td>
<td align="center" valign="middle">0.387</td>
<td align="center" valign="middle">0.268</td>
<td align="center" valign="middle">0.193</td>
<td align="center" valign="middle">0.153</td>
<td align="center" valign="middle">0.124</td>
<td align="center" valign="middle">0.0991</td>
<td align="center" valign="middle">0.0754</td>
<td align="center" valign="middle">0.0601</td>
</tr>
<tr>
<td align="center" valign="middle">Al</td>
<td align="center" valign="middle">1.2</td>
<td align="center" valign="middle">0.868</td>
<td align="center" valign="middle">0.641</td>
<td align="center" valign="middle">0.443</td>
<td align="center" valign="middle">0.320</td>
<td align="center" valign="middle">0.253</td>
<td align="center" valign="middle">0.206</td>
<td align="center" valign="middle">0.164</td>
<td align="center" valign="middle">0.125</td>
<td align="center" valign="middle">0.100</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle">
<p style="font-family: verdana , arial , helvetica , sans-serif">Nominal Cross-section</p>
<p style="font-family: verdana , arial , helvetica , sans-serif">mm<sup>2</sup></p>
</td>
<td align="center" valign="middle">400</td>
<td align="center" valign="middle">500</td>
<td align="center" valign="middle">630</td>
<td align="center" valign="middle">800</td>
<td align="center" valign="middle">1000</td>
<td align="center" valign="middle">1200</td>
<td align="center" valign="middle">1400</td>
<td align="center" valign="middle">1600</td>
<td align="center" valign="middle">1800</td>
<td align="center" valign="middle">2000</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle">
<p style="font-family: verdana , arial , helvetica , sans-serif">20<sup>o</sup>C DC Resistance</p>
<p style="font-family: verdana , arial , helvetica , sans-serif">&Omega;/km</p>
</td>
<td align="center" valign="middle">Cu</td>
<td align="center" valign="middle">0.0470</td>
<td align="center" valign="middle">0.0366</td>
<td align="center" valign="middle">0.0283</td>
<td align="center" valign="middle">0.0221</td>
<td align="center" valign="middle">0.0176</td>
<td align="center" valign="middle">0.0151</td>
<td align="center" valign="middle">
<p>0.0123</p>
</td>
<td align="center" valign="middle">0.0108</td>
<td align="center" valign="middle">0.0096</td>
<td align="center" valign="middle">0.0086</td>
</tr>
<tr>
<td align="center" valign="middle">Al</td>
<td align="center" valign="middle">0.0778</td>
<td align="center" valign="middle">0.0605</td>
<td align="center" valign="middle">0.0469</td>
<td align="center" valign="middle">0.0367</td>
<td align="center" valign="middle">0.0291</td>
<td align="center" valign="middle">0.0247</td>
<td align="center" valign="middle">0.0202</td>
<td align="center" valign="middle">0.0177</td>
<td align="center" valign="middle">0.0157</td>
<td align="center" valign="middle">&nbsp;</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle">
<p style="font-family: verdana , arial , helvetica , sans-serif">Nominal Cross-section</p>
<p style="font-family: verdana , arial , helvetica , sans-serif">AWG</p>
</td>
<td align="center" valign="middle">6</td>
<td align="center" valign="middle">5</td>
<td align="center" valign="middle">4</td>
<td align="center" valign="middle">3</td>
<td align="center" valign="middle">2</td>
<td align="center" valign="middle">1</td>
<td align="center" valign="middle">1/0</td>
<td align="center" valign="middle">2/0</td>
<td align="center" valign="middle">3/0</td>
<td align="center" valign="middle">4/0</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle">
<p style="font-family: verdana , arial , helvetica , sans-serif">20<sup>o</sup>C DC Resistance</p>
<p style="font-family: verdana , arial , helvetica , sans-serif">&Omega;/km</p>
</td>
<td align="center" valign="middle">Cu</td>
<td align="center" valign="middle">1.3219</td>
<td align="center" valign="middle">1.0453</td>
<td align="center" valign="middle">0.8298</td>
<td align="center" valign="middle">0.6594</td>
<td align="center" valign="middle">0.5211</td>
<td align="center" valign="middle">0.4149</td>
<td align="center" valign="middle">0.3281</td>
<td align="center" valign="middle">0.2605</td>
<td align="center" valign="middle">0.2065</td>
<td align="center" valign="middle">0.1640</td>
</tr>
<tr>
<td align="center" valign="middle">Al</td>
<td align="center" valign="middle">2.1699</td>
<td align="center" valign="middle">1.7167</td>
<td align="center" valign="middle">1.3631</td>
<td align="center" valign="middle">1.0802</td>
<td align="center" valign="middle">0.8551</td>
<td align="center" valign="middle">0.6783</td>
<td align="center" valign="middle">0.5401</td>
<td align="center" valign="middle">0.4276</td>
<td align="center" valign="middle">0.3376</td>
<td align="center" valign="middle">
<p>0.2688</p>
</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle">
<p style="font-family: verdana , arial , helvetica , sans-serif">Nominal Cross-section</p>
<p style="font-family: verdana , arial , helvetica , sans-serif">MCM</p>
</td>
<td align="center" valign="middle">250</td>
<td align="center" valign="middle">300</td>
<td align="center" valign="middle">350</td>
<td align="center" valign="middle">400</td>
<td align="center" valign="middle">450</td>
<td align="center" valign="middle">500</td>
<td align="center" valign="middle">550</td>
<td align="center" valign="middle">600</td>
<td align="center" valign="middle">650</td>
<td align="center" valign="middle">700</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle">
<p style="font-family: verdana , arial , helvetica , sans-serif">20oC DC Resistance</p>
<p style="font-family: verdana , arial , helvetica , sans-serif">&Omega;/km</p>
</td>
<td align="center" valign="middle">Cu</td>
<td align="center" valign="middle">0.1386</td>
<td align="center" valign="middle">0.1158</td>
<td align="center" valign="middle">0.0991</td>
<td align="center" valign="middle">0.0865</td>
<td align="center" valign="middle">0.0772</td>
<td align="center" valign="middle">0.0695</td>
<td align="center" valign="middle">0.0630</td>
<td align="center" valign="middle">0.0579</td>
<td align="center" valign="middle">0.0534</td>
<td align="center" valign="middle">0.0495</td>
</tr>
<tr>
<td align="center" valign="middle">Al</td>
<td align="center" valign="middle">0.2273</td>
<td align="center" valign="middle">0.1897</td>
<td align="center" valign="middle">0.1623</td>
<td align="center" valign="middle">0.1421</td>
<td align="center" valign="middle">0.1263</td>
<td align="center" valign="middle">0.1138</td>
<td align="center" valign="middle">0.1032</td>
<td align="center" valign="middle">0.0948</td>
<td align="center" valign="middle">0.0874</td>
<td align="center" valign="middle">0.0813</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle">
<p style="font-family: verdana , arial , helvetica , sans-serif">Nominal Cross-section</p>
<p style="font-family: verdana , arial , helvetica , sans-serif">MCM</p>
</td>
<td align="center" valign="middle">750</td>
<td align="center" valign="middle">800</td>
<td align="center" valign="middle">900</td>
<td align="center" valign="middle">1000</td>
<td align="center" valign="middle">1100</td>
<td align="center" valign="middle">1200</td>
<td align="center" valign="middle">1300</td>
<td align="center" valign="middle">1400</td>
<td align="center" valign="middle">1500</td>
<td align="center" valign="middle">1600</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle">
<p style="font-family: verdana , arial , helvetica , sans-serif">20<sup>o</sup>C DC Resistance</p>
<p style="font-family: verdana , arial , helvetica , sans-serif">&Omega;/km</p>
</td>
<td align="center" valign="middle">Cu</td>
<td align="center" valign="middle">0.0463</td>
<td align="center" valign="middle">0.0434</td>
<td align="center" valign="middle">0.0386</td>
<td align="center" valign="middle">0.0347</td>
<td align="center" valign="middle">0.0316</td>
<td align="center" valign="middle">0.0289</td>
<td align="center" valign="middle">0.0237</td>
<td align="center" valign="middle">0.0248</td>
<td align="center" valign="middle">0.0231</td>
<td align="center" valign="middle">0.0217</td>
</tr>
<tr>
<td align="center" valign="middle">Al</td>
<td align="center" valign="middle">0.0759</td>
<td align="center" valign="middle">0.0711</td>
<td align="center" valign="middle">0.0630</td>
<td align="center" valign="middle">0.0569</td>
<td align="center" valign="middle">0.0518</td>
<td align="center" valign="middle">0.0473</td>
<td align="center" valign="middle">0.0437</td>
<td align="center" valign="middle">0.0405</td>
<td align="center" valign="middle">0.0379</td>
<td align="center" valign="middle">0.0357</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-86w0q" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-86w0q" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Certifications</span></div>
<div style="padding: 10.0px 0">
</div>
</div>
<div id="ali-anchor-AliPostDhMb-7jj9h" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-7jj9h" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Production Equipment</span></div>
<div style="padding: 10.0px 0">
</div>
</div>
<div id="ali-anchor-AliPostDhMb-iv64k" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-iv64k" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Test Equipment</span></div>
<div style="padding: 10.0px 0">
</div>
</div>
<div id="ali-anchor-AliPostDhMb-ey0ya" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-ey0ya" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Packaging &amp; Shipping</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/46kv-concentric-power-cable-with-100-insulation-level-500mcm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
