<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>3*300 cable &#8211; JYTOP Cable</title>
	<atom:link href="https://www.baoliyy.com/tag/3300-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.baoliyy.com</link>
	<description>Manufacture AAC/AAAC/ACSR CONDUCTOR,XLPE Cable, PVC Cable, ABC Cable, Power Cable</description>
	<lastBuildDate>Tue, 21 Jun 2022 00:58:06 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>13.8kv 3*300 underground cable specifications</title>
		<link>https://www.baoliyy.com/13-8kv-3300-underground-cable-specifications/</link>
				<comments>https://www.baoliyy.com/13-8kv-3300-underground-cable-specifications/#respond</comments>
				<pubDate>Tue, 21 Jun 2022 00:58:06 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[sonorouscable]]></category>
		<category><![CDATA[13.8kv cable]]></category>
		<category><![CDATA[3*300 cable]]></category>
		<category><![CDATA[underground cable specifications]]></category>

		<guid isPermaLink="false">https://www.baoliyy.com/13-8kv-3300-underground-cable-specifications/</guid>
				<description><![CDATA[12/20 24 kv 3*300 underground cable specifications &#160;&#160; &#160; &#160; &#160; &#160; XLPE Insulation Power Cable 3~35(33) kV Type Cu or Al/XLPE/CTS or CWS/PVC, Cu/XLPE/CTS/PVC/SWA/PVC Voltage 1.8/3kV, 1.9/3.3kV,6/10kV, 6.35/11kV, 8.7/10kV, 8.7/15kV, 12/20kV, 12.7/22kV, 18/30kV, 19/33kV,26/35kV Cores 1C and 3C Range of Nominal cross section 25 mm2 &#8211; 630 mm2 Application 13.8kv cable&#160;is suitable for use [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="text-align: center"><span style="background-color: #00ccff;color: #000000;font-size: 24.0px;font-family: times new roman , times"><em><strong>12/20 24 kv 3*300 underground cable specifications &nbsp;&nbsp;</strong></em></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 1.0cm" align="left">
<td style="width: 19.0cm" colspan="3" valign="top">
<p><strong><span style="font-style: normal;font-weight: normal;font-size: 15.0pt;line-height: normal;font-family: arial , sans-serif">XLPE Insulation Power Cable 3</span></strong><strong><span style="font-size: 15.0pt">~</span></strong><strong><span style="font-style: normal;font-weight: normal;font-size: 15.0pt;line-height: normal;font-family: arial , sans-serif">35(33) kV</span></strong><strong></strong></p>
</td>
</tr>
<tr style="height: 117.25pt" align="left">
<td colspan="3" valign="top">
</td>
</tr>
<tr style="height: 36.2pt" align="left">
<td style="width: 191.4pt" align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Type</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Cu or Al/XLPE/CTS or CWS/PVC, </span></p>
<p align="left"><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Cu/XLPE/CTS/PVC/SWA/PVC</span></p>
</td>
</tr>
<tr style="height: 45.35pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Voltage</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">1.8/3kV, 1.9/3.3kV,</span><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">6/10kV, 6.35/11kV, 8.7/10kV, 8.7/15kV, 12/20kV, 12.7/22kV, 18/30kV, 19/33kV,</span><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">26/35kV</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Cores</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">1C and 3C</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Range of Nominal cross section</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">25 mm<sup>2</sup> </span><span style="font-size: 12.0pt">&#8211;</span><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif"> 630 mm<sup>2</sup></span></p>
</td>
</tr>
<tr style="height: 86.25pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Application</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">13.8kv cable&nbsp;is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kV</span><span style="font-size: 12.0pt">&#8211;</span><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">26/35kV.</span> <span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">For laying indoors, in tunnel, cable trench, well or direct in ground.</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Standard</span></p>
</td>
<td colspan="2">
<p><span style="font-family: arial , sans-serif">IEC60502, BS6622, AS/NZS1429, GB/T12706,</span> <span style="font-family: arial , sans-serif">ICEA S-94-649-2004</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="height: 22.7pt" rowspan="5" align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Constructions</span></p>
</td>
<td style="width: 106.3pt">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Conductor: </span></p>
</td>
<td style="width: 240.95pt">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Copper or Aluminium Compacted </span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Insulation:</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">XLPE</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Metallic screen:</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Copper tape or Copper wire</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Armour:</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Steel Wire Armour or Steel Tape Armour</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Sheath:</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">PVC, PE or LSZH</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Max. Operating Temperature</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">90 ℃</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Packing</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Steel drum or as per requirement</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Production Capacity</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">10 kilometer / day </span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Delivery time</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">10 </span><span style="font-size: 12.0pt">&#8211;</span><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif"> 15 working days</span></p>
</td>
</tr>
<tr style="height: 45.35pt" align="left">
<td align="right">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">Remark</span></p>
</td>
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 12.0pt;line-height: normal;font-family: arial , sans-serif">13.8kv cable&nbsp;can be of flame retardance, fire resistance, environment friendly or other property</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp;&nbsp;<span style="line-height: normal;font-family: calibri , sans-serif;font-size: 13.5pt">&nbsp;</span></p>
<p><span style="font-size: 18.0px">&nbsp; 13.8kv cable </span><span style="line-height: normal;font-family: calibri , sans-serif;font-size: 13.5pt"><span style="font-size: 18.0px">Pac</span>king Like this:&nbsp;</span></p>
</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 24.0px">Pls feel free to contact:&nbsp;</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 24.0px">Jessie Li&nbsp;</span></p>
<p><span style="font-size: 24.0px">mobile: +86-15254112213</span></p>
<p><span style="font-size: 24.0px">email: jessie(at)hldlcable.com</span></p>
<p><span style="font-size: 24.0px">skype: hongliangcablesales8</span></p>
<p>&nbsp;</p>
<p><span style="font-family: calibri , sans-serif">&nbsp;</span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://www.baoliyy.com/13-8kv-3300-underground-cable-specifications/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
